Document e58BnQrrga4k0rmya9vrEd88G
W&-
j Pel.
M-y.;
m %>
p
$*#.. fig?' $?'-,
&
INDEX
HEATING VENTILATING AIR CONDITIONING
GUIDE 1953
Technical Data Section Chapters 1--51 and Pages 1-1096
A
Abatement air pollution, 151,154 ' smoke, 8, 155, 324
>
Abbreviations, 11 Absolute
humidity. 5 pressure,7 . temperature, 9, 30
.. zero, 1, 30 Absorbents, 850
process, 850 , temperature, pressure,
centration, 851
eon-
Absorbers
duct, sound, 896 outlet, 901
plate cells, 899 plenum, 901 Absorption systems, 823 Acceleration, 1 Acclimatization, 118 Acoustics, 887 Activated alumina, 846 Activated carbon, 147. 846, 1032 Activated bauxite, 847 Adiabatic, 1 miring
two air streams, 57 saturation, 60
Adsorbents, 845
process, 847
temperature, pressure, con*
centration, 851
Adsorption, odor, vapor, 156,
750 .
.
Aerosol, 1, 134,151 i
Air
change measurement, 1081
change method, 222, 256
chemical vitiation of, 111, 152,
156
circulation, 112, 449, `459, 647,
685, 1030
circulation in dry, 1020
- classification of impurities,
151, 740
dust, 151, 740
lint, 151, 740
cleaner, 151, 739, 1030
viscous impingement type,
741
cleaning, 739
cleaning devices, 739
charged media. 744
classification of, 739
1
electrostatic, 743
installation, 748
maintenance, 747
performance, 745
safety requirements, 749
selection, 747
testing, 745
vapor adsorption, 749
combustion, 345, 346
conditioning process, 647, 959
contaminants. 111, 151, 981,
1086
cooled condensers, 632
Air (continued) coolers, 595, 599 cooling, tropics, 136 current measurement, 1080 dehumidification, 845 'distribution, 449, 459, 661,
*
1030, 1036, 1039 air entrainment, 663 application of methods, 681,
1030 balancing the system, 676 ceiling outlets, 674 definitions, 662 design methods, 703 - duct approaches to outlets,
451, 677 flow patterns, 677
friction chart, 686, 687 furnace systems, -449, 459
guide vanes, 460, 669 induction, 663
jet pattern, 664 mechanics, 663 ' momentum theory, 663
outlet location, 460, 461, 674,
678 outlet performance, 671, 678
outlets, 673 parallel slots, 665
railway car, 1030 ' recommended velocity, 460,-
702 return and exhaust intakes,
680, 904 return grille, 449, 451 room air motion. 670, 672 selection, 675 spread, 663, 668 standards for, 661. throw, 662, 666 vanes, 450, 460, 669 / velocity, 575, 686, 702 velocity across jets, 664 vertical drop and rise, 670 volume control, 679 wall outlets, 460, 670, 673 . duct construction, 710, 993 duct design, 462, 685, 701, 712,
988 duct friction lo6s, 685 dust concentrations, 155, 160,
161 excess, 328, 342, 346, 375 filter, 739 flow resistance of coils, 793 impurities, 113, 151, 739 infiltration, 217
causes of, 218 v due to wind pressure, 218
through walls, 218 leakage, 217-222, 328
moist, 25 motion. 122 movement, influence of, 117 movement, measurement of,-
1075, 1079
outdoor, 112, 647 physical impurities in, 113,
151, 155, 739
pollution, 151, 155 abatement, 155, 324, 981
primary, 326 quantity required, 112, 345,
346, 1031, 1033
XI
Air {continued) refrigeration cycle, 820 room motion, 657, 659 saturated, 1 secondary. 326, 343, 375 space conductance, 170, 180
' standard, 1 sterilization of, 132,142 supply and return openings,. 450,461,671, 673 supply opening noise, 673,'901 temperature requirements, 123, 126, 247, 264, 960; 970,
1039 theoretical requirements, 112,
344, 346, 1040 thermodynamics of, 23 unit cleaning devices, 739, 748,
757 washers, 1,-757 Air change method computing infiltration-, 220,
255
Air conditioning, 1 aircraft, 1035
automobiles in -summer, 1035 central system, 647 comfort, 2 hospitals, 131t148 humidity, table, 960 industrial, 959
atmospheric conditions re quired, 265, 960-970
calculations, 975 general requirements, 959 problem classification, 959 typical applications, 959 owning ana operating cost, 949 ' passenger bus in summer, 1034
prooesses, 54 adiabatic mixing, 57
. adiabatic saturation, 60 cooling, 55 heating, 54
' railway passenger car, 1029
ship, 1038 stoker-fired units, 356 storage systems, 825 streetcar, 1033 summer design conditions,
264 , 265, 267 temperature table, 264, 267,
960 transportation, 1029 treatment of disease, 131
unit, 589
Air cooler, 589 units, 589, 599 defrosting, 600 design, 599 operation, 601 performance, 600 ratings, 600 types of, 599
Air filters, 739 Air pollution, 154
control, 155, 324, 750 Air requirements. 112, 1031 Air supply opening noises, 673,
901 Air velocity, 460, 575, 663, 679,
693, 702, 982, 984