August 6, 1973
GP-1436
Mr.- P. C. Johns New York State Department of Labor Division of Industrial Hygiene 2447 Sheridan Drive Tonawanda, New York 14150
Subject:
BPA-218-73 Bag Packer Dust Collection System Joint Cement, Akron. New York Gypsum Plant. Fan System No. 10
Dear Mr. Johns:
Enclosed are the necessary forms and drawings for our application to install an exhaust system for the above subject. Our original application for this system was disapproved by your department on July 6, 1973, due to the fact that the drawings did not contain sufficient details.
With reference to our proposed Fan System No. 9 for the bag slitter vent hood, we have deleted this item because we are now obtaining air velocities of 275 feet per min ute across the face of the hood. Your vent requirements for this area were 200 feet per minute. The increased velocity was accomplished by totally enclosing three sides of the vent hood.
If additional details or documentation is required, please feel free to contact me at the Portland office.
Sincerely,
L
George Turner Project Engineer Gypsum Division
GTsvm Enc. cc: Mr. I. A. Hoekstra - Erie County, New York
Mr. J. D. Rauch - Akron / Mr. W. Hammer - Akron Mr. V. J. Tretter - Portland
SGP 0021910
4. Air contaminant emissions to outer air; list by contaminant name and indicate whether contaminant is (s) solid, (1) liquid, or (g) gas. Describe color and/or odor of visible and/or odorous contaminants.
Contaminant
Joint Cement Dust (white, odorless)
Quantity (lb/hr) 0.04
/
Contaminant
%
Quantity (lb/hr)
-
-
Describe method for determining emissions:
Estimate 40 Lbs/Hr of Joint Cement Dust to 99.9% Efficient Cyclone & Baghouse
Emissions: (40 Lbs^ir) (0.001) = 0.04 Lbs,Alr
5. Air or gas flow rate
If cyclic, SCFM/cycle,
; hrs/cycle
; cycles/yr
If continuous, SCFM
3650
; hrs/day
20
; days/yr 340 (Average)
6. Physical characteristics of emission point
a. gas temperature at point of discharge:
70 F.
b. -Inside dimensions of outlet. ^ in. x 13% in. or
--------------7?^ /^v> -\
It - _ / " --y
in. dia(n^tfer o
c. height above eround 14'6"
ft.
7. Fuel (complete if fuel used as a process constituent) "Not Used"
a. Coal (Type) Anthracite_
Bituminous_
; lbs/hr.
ZSulfur by Wgt. \
b. Oil (Grade) 2 4
5 6 GPH
ZSulfur by Wgt._
c. Gas (Type) MFD
; Nat.; _________ CFH; BTU/CF
8. Is this a new or existing source?
New
9. If existing, has an environmental rating been certified for this emission source? Not Applicable
0. If yes, give "E" number assigned
SGP 0021911
NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION AIR RESOURCES MANAGEMENT PROCRAM
APPLICATION TO CONSTRUCT OR MODIFY A SOURCE OF AIR CONTAMINATION FOR COMPLIANCE WITH 10 NYCRR 175-180
PROCESS. EXHAUST OR VENTILATING SYSTEM
9TE: See form Alr-100.1 for application instructions and form Air-51 for address of field representative where application Is filed.
1. DATE OF APPLICATION
August 6, 1973
EMISSION SOURCE REFERENCE NO.
Not Assigned
APPLICANT, LEAVE BLANK
1- E-
2. APPLICANT (Finn, Municipality, School, etc.) AND MAILING ADDRESS
Georgia-Pacific Corporation 900 S.W. 5th Avenue Portland, Oregon 97204
3. NAME OF APPLICANT'S REPRESENTATIVE
George Turner
TITLE
Project Engineer
4. NAME AND ADDRESS OF AUTHORIZED AGENT (If any) SUBMITTING APPLICATION:
None
PHONE NUMBER
503-222-5561
ATTENTION
PHONE NUMBER
5. NAME OF PROFESSIONAL ENCINEER OR ARCHITECT PREPARING PLANS
N.Y.S. LICENSE NUMBER
Ear land E. Harvey______ ______________
6. LOCATION OF INSTALLATION STREET ADDRESS
City
Bloomingdale Road
VII Use Q Town
BUILDING
Joint Cement Mfg.
FLOOR
19250
CITY, VILLAGE, TOWN, COUNTY
Akron, Erie County
DEPARTMENT
Packing
7. TYPE OF INSTALLATION
IF MODIFICATION, LIST NEW AND EXISTING EQUIPMENT
New
Modification
8. a) HAS PREVIOUS APPLICATION FOR AIR POLLUTION CONTROL APPROVAL BEEN MADE FOR THIS INSTALLATION?
b) IS THIS A RESUBMISSION OF A PLAN PREVIOUSLY DISAPPROVED?
Enter Previous Application Number BPA--218--73
C) IS THIS A MODIFICATION OF A PLAN PREVIOUSLY APPROVED? Enter Previous Application No.
YES j
Q
NO
9. CAS CLEANING OR TREATMENT EQUIPMENT: If none, check here"!
a. Type Cyclone & Baghouse b. ManufacturerCyclone : "Dustex 1c. Model or Catalog No.
(Reverse Air Cleaning) Jaghouse: "Flex-Kleen"
Cyclone: 28-1005-32 Baghouse: 84-CT-D4
d. Size Cyclone: 2' 8" Dia.
Baghox^usoeT: o!6' ' *
x
14--3----Iong-
g. Rated Overall Emfficiency
e. Design Capacity or Requirement
ACFM 3650
Deg. F 70
h. Cost of Cleaner
f. Maximum Pressure Drop
16
Inches W. G.
99.9 %
10. ARE COLLECTED AIR CONTAMINATES RECYCLED OR SALVAGED? Describe recycling, salvage process or disposal method.
Complete Installation:
3Yes Q No
$20,000.00
Collected material from cyclone and baghouse is recycled to bag packer feud hopper via bucket elevator.
11. EXPECTED PROIECT COMPLETION DATE
December 15, 1973
12. HAS APPLICANT COMPLIED WITH OTHER APPLICABLE CODES? 0 Yes No
13. ENUMERATE DRAWING NUMBERS OF PLANS SUBMITTED IN TRIPLICATE WITH THIS APPLICATION
#40-73-1 #40-73-2 #40-73-3
#E-41-251 #7307-1
14. TYPE OF ESTABLISHMENT (Product manufactured or service rendered) (e.g. Foundry, Retail Store, Municipal, Lighting Fixtures, Toys, etc.)
Gypsum Products Manufacturer
is Type OF OPFFaT'ON OR PROCFSS le y. Woodworking, Coating, etc.)
SGP 0021912
it. EMISSION SATE POTENTIAL* (The rate In pounds per hour it which air contaminants would be emitted to the outer air In the absence of air pollution control facilities or other control measures.)
A. Gas and Liquid Particulates Type
"Not Applicable"
Quantity (Ibs/hr)
Quantity (tons/yr)
B. Solid Particulates
Type
Joint Cement Oust
\ .--
Process Weight (Total Weight of all materials introduced into a process; e.g. coke, limestone, etc.)
4 Tons per hour
C. Average hours operation
20 per day
120
per week
SEE PAIT T87 FOI DEFINITIONS AND APPLICABIUTV
17. A. Proposed or Certified Environmental Rating (for process, exhaust or 8. If Environmental Rating has been certified, enter here
ventilation system applicable under Pait 187)
E-
18. EMISSIONS (Actual) A. Gaseous
Not appli2 able
Material
Quantity (lb/hr)
Stack Concentration ppm
8. Particulates Materia!
Joint Cement Dust
Quantity (Ib/hr) 0.04
Undiluted Exhaust Gas (Ib/lOOOlb)
Not applicable
19. POINT OF DISCHARCE A. Location
Through Wall
. Horizontal distance to nearest bldg beyond property line cjqq
C. Exit gas or air temperature (*F)
70
20. FUEL USED IN PROCESS
"None"
A. Coal-Type
Ibs/hr
B. Height (ft above ground) 14* 6"
E. Exit inside - dimensions (inches) 12 X 13*5"
H. Air or gas flow rale (CFM) 3225
X Sulfur by Weight
C. Elevation at ground level
, , 686 Ft.
F. Exit gas or air velocity (tt per minute)
1. Draft
3500
Q Natural 2 Mechanical
B. Oil-Grade
GPH
X Sulfur by Weight
C. Gas-Type
Cu ft/hr
'X
SIGNATURE of individual or official
George Turner
title
Project Engineer/y/
:*?
Any person knowingly moking any faTse statement or false report in connection with this application shall be lioble^fpripenolties os
prescribed by low.
' ^3 . " cos /
SGP 0021913
SHEET, FORM IH-212.1 FUR UU/UARLC It* i nt rwcraka i lun wr uammuj < j / j . *-m .
<ntCLEANING DATA
IS AIK CLEANING EQUIPMENT PROVIDED? 19. TYPE OF AIR CLEANING EQUIPMENT (H tny) TO BE USED (Cretan*. Hoth Anmtlor. F.le.t
Syes
no
Cyclone and Baghouse (Reverse Air deeming)________
13a ir cleaner manufacturer _
Cyclone: Dustex, Inc.
. 20b. MODEL OR CATALOG NO.
Cyclone: 28-100S-32
20c. SIZIE
Cycl one; 2* 8" Dia. x
- ^nghnnsp:___Fleix-Kle.en.__Inc.
Baghouse: 84--CT-54______
8* Q_. JLiQng_
21 aXIMUM PRESSURE DROP THROUGH AIR CLEANER AT Cyclone 5"
Baghouse: 6*0" Oia.
OPERATING CONDITIONS (-W.C.)
Baghouse; 7"
14*3" Long
AN DATA {If more than one fan system is shown on plans, each fan should be numbered and described)
O. FAN NO.
22. MFR.'S NAME
FAN TI'PE
DESIGN
SIZE
10
New York Blower Co.
Centrifugal
Material Handling
192
*. MFR.'S RATING: RPM
CFM
S.P. (In- wmfr)
B.H.P.
MOTOR H.P. 25. FAN CONDITION
3130 3650
16"
15.9
20
t?C ! New | | Reconditioned 1 1 Existing
6. DESIGN REQUIREMENTS:
CFM
3225
S.P. (In. wmfr)
14"
127. FAN INLET DIAMETER
| 12 taeh,,
28. FAN OUTLET DIAMETER OR SIZE
12 BC 13%
inch*!
UMENSIONS OF UNITS EXHAUSTED (Identify oo plan by letter; uae separate sheet if necessary)
r-~\- - - p^ti -v1 -r
rurr^rn py
SGP 0021914
Division of Indusaiel Hygiene Eogineeting Section
EXHAUST SYSTEM PLAN
PLAN NO. DATE REC'D. FEE REC'D.
//
FILING INSTRUCTIONS - ONE COMPLETED COPY OF THIS FORM MUST BE FILED FOR EACH FAN SYSTEM IN THE EXHAUST PLANS BEING SUBMITTED. Forward exhaust system plans IN TRIPLICATE, together with one completed copy of this form for each .on system, to the Engineering Section of the Division of Industrial Hygiene at one of the following Department of Labor Offices. Plans for exhaust systems to be installed in the counties of Cattaraugus, Chautauqua, Erie, Genesee, Livingston, Monroe, Niagara, Ontario, Orleans, Woyne, Wyoming and Yates should be sent to: 2447 SHERIDAN DRIVE, TONAWANDA, N.Y. 14150, Plans for exhaust systems to be installed in counties other than those listed above, should be submitted to: 80 CENTRE STREET, NEW YORK, N.Y. 10013.
IMPORTANT: Effective June 1, 1963, the Industrial Commissioner is required by section 204-a of the Labor Law to charge a FEE
FOR THE EXAMINATION OF EXHAUST PLANS. Please forward with the plans a check or money order payable to the Industrial
Commissioner, in accordance with the following fee schedule FOR EACH FAN SYSTEM:
CATEGORY A
CATEGORY B
"Simple single booths and enclosures, such os spray booths; canopy
All systems other than category A.
hoods; dilution, general and natural draft ventilation systems".
Design CFM
Fee
Design CFM
Fee
less than 250 250 or more but less than 1,000
$10 20
less than 5,000 5,000 or more
$10 20
1,000 or more but less than 5,000 5,000 or more but less than 10,000 10,000 or more
30 40 50
1. FIRM NAME
Georgia-Pacific Corporation_______________________________________
2. MAILING ADDRESS
900 S.W. 5th Avenue, Portland, Oregon 97204
3. PLANT LOCATION (Stft and Numbar, City, Town, Viilmgo; County)
Bloomingdale Road, Akron, Erie County, New York 14001
44. PLANT REPRESENTATIVE TO BE CONTACTED REGARDING EXHAUST SYSTEM PLANS 4b. TITLE
George Turner
Project Engineer
5. NUMBER OF IN-PLANT EMPLOYEES AT THE ABOVE PLANT LOCATION:
TOTAL
135
MALE
131
FEMALE
4
6. NO. OF EMPLOYEES AT OPERATIONS OR MACHINES
70
7. AUTHORIZED AGENT (H any) SUBMITTING PLANS (Eng.. Da,ifiner, Con.u/linfi Firm. Etc.) LETTER OF AUTHORIZATION MUST ACCOMPANY PLANS
None
. BUSINESS ADDRESS OF AGENT
9. NO. OF FAN SYSTEMS SHOWN ON PLAN (Fan Symtama Should Ba Numbarad)
One (1)
10. SUBMITTED FOR COMPLIANCE
WITH INDUSTRIAL CODE RULE NO. 10NYCRR-80
general data
FAN SYSTEM NO 10
AMOUNT OF FEE FNfl nsFn
* $30.00 previously sent for this system
II. LOCATION OF SYSTEM
. building
Joint Cement ManufacturingFLOOr
one
None *
Bage. department Packing
d. NUMBER OF FLOORS IN BLDG.
one
I2. IS PROPOSED INSTALLATION NEW?
_______ [x] YES QUO
IJb. ADDITION TO OR RECONSTRUCTION OF EXISTING SYSTEM
YES
HN0
IJ. DOES THIS PLAN AMEND
[x] YES
PREVIOUSLY SUBMITTED PLAN?
I NO
IF YES. GIVE PREVIOUS PLAN NO. AND AMOUNT OF FEE PAID
BPA-218-73 ($30.00)
___________
14. IS THIS INSTALLATION TO COMPLY WITH ORDERS OR SPECIFIC RECOMMENDATIONS ISSUED BY THIS DEPARTMENT?
YES
NO
IF YES. GIVE DATE OF ISSUANCE
October 27, 1972
15. IS DISCHARGE OF SYSTEM TO BE RECIRCUL ATED TO THE WORKROOM* || YES
f<0
(*Ot achargad Air Which Conlatna Dangaroua Air Conlnlnifa Shall Sot Ba Racircuiatad. * - Ru/a ig-g.S)
16 MSCHARGE POINT: l~" i ABOVE ROOF i I OUT OF WINDOW 20 FEET TO NEAREST FIRE ESCAPE OR EXIT
I THROUGH SIDE WALL XJCXEOECXXJCXaC
I I OTHER
5 FEET TO NEAREST WINDOW
17. MAKE-UP AIP. EQUAL IN VOLUME TO THAT EXHAUSTED, TO BE SUPPLIED BY
Natural Draft
17. MEANS FOR HEATING MAKE-UP AIR
None
SGP 0021915
NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION DIVISION OF AIR RESOURCES
BUREAU OF AIR QUALITY CONTROL 41 STATE STREET
ALBANY, NEW YORK U207
ENVIRONMENTAL ANALYSIS REPORT - SUMMARY OF SOURCES
For completion kf applicant (in triplicate)
Report No.
Use ana copy el this (arm at a cover sheet (or aach copy o( the Environmental Analysis Report submitted in triplicate
1. Nemo o( firm or owner ,
Georgia-Pacific Corporation
BAQC Assign.
2. Address of installation ,
Bloomingdale Road, Village of Akron, Erie
3. Person to contact in re(aranca to this submission,
Georae Turner. Project Engineer
Name qqq g # w. 5th Avenue
4. Proposed Environmental Rating(s)
Portland, Oregon 97204
Address
Emission Point No.
Not Assigned
Process, Exhaust or Ventilating System
Bag Packer, Joint Cement Manufactur ing
Proposed Env< Rot.
Emission Point No.
Process, Exhaust or Ventilating System
Proposed Env. Rot.
Continue on reverse side for listing of proposed ER's.
S. Dote Aligned fi, 1 Q7*3a. Signoture , rf-*t
1 I t ----
por completion by field reprosentotlvo
I recommend (occeptonce) (denial) of the proposed environmental roting(s)
Remorks
________________.
7. Title
Project: Engineer
L (. Oet* ,
9. Signoture ,
10. Title
SGP 0021916
oin NjO.
Vtnrilotmq Syittn
ER
Point No.
|__________ Vontilotinj Systom
ER
SGP 0021917
0 S.W. Fifth Avanu# Portland, Oregon 97204 503/222 5561
August 6, 1973
Mr.- F. C. Johns New York State Department of Labor Division of Industrial Hygiene 2447 Sheridan Drive Tonawanda, New York 14150
Subject:
BPA-218-73 Bag Packer Dust Collection System Joint Cement, Akron. New York Gypsum Plant. Fan System No. 10
Dear Mr. Johns:
Enclosed are the necessary forms and drawings for our application to install an exhaust system for the above subject. Our original application for this system was disapproved by your department on July 6, 1973, due to the fact that the drawings did not contain sufficient details.
With reference to our proposed Fan System No. 9 for the bag slitter vent hood, we have deleted this item because we are now obtaining air velocities of 275 feet per min ute across the face of the hood. Your vent requirements for this area were 200 feet per minute. The increased velocity was accomplished by totally enclosing three sides of the vent hood.
If additional details or documentation is required, please feel free to contact me at the Portland office.
Sincerely,
George Turner Project Engineer Gypsum Division
GT:vm Enc. cc: Mr. I. A. Hoekstra - Erie County, New York
Mr. J. D. Rauch - Akron Mr. W. Hammer - Akron Mr. V. J. Tretter - Portland
SGP 0021918
4. Air contaminant emissions to outer air; list by contaminant name and indicate whether contaminant is (s) solid, (1) liquid, or (g) gas. Describe color and/or odor of visible and/or odorous contaminants.
Contaminant
Joint Cement Dust (white, odorless)
Quantity (lb/hr) 0.04
'
Contaminant %
Quantity (lb/hr)
.
*
Describe method for determining emissions:
Estimate 40 Lbs/Hr of Joint Cement Dust to 99.9% Efficient Cyclone & Baghouse
Emissions: (40 Lbs/ftr) (0.001) = 0.04 Lbs/ftr
5. Air or gas flow rate
If cyclic, SCFM/cycle; hrs/cycle
; cycles/yr
If continuous, SCFM
3^30; hrs/day
^______________ ; days/yr 340 (Average)
.6 Physical characteristics of emission point
a. gas temperature at point of discharge:
70 F
b. Inside dimensions of outlet ^ In. x ^~3^ in. or
c. height above ground 1416"ft. 7. Fuel (complete if fuel used as a process constituent) "Not Used"
a. Coal (Type) Anthracite; Bituminous; lbs/tir. ZSulfur by Wgt.^
b. Oil (Grade) 2 4 5 6 GPH ZSulfur by Wgt.
c. Gas (Type) MFD; Nat.; _______________ CFH; BTU/CF
8. Is this a new or existing source?
New
9. If existing, has an environmental rating been certified for this emission source? Not Applicable
7. If yes, give "E" number assigned
SGP 0021919