Document e1zXKw7VJagEQ2QeR5YdbK1ZM

460 CHAPTER 25 1965 Guide And Data Book poorly fitted window. All of the figures for double-hung Table 3 .... infiltration Through Walts' wood windows are for the unlocked condition. Just bow a Frprmnarl jn ecfcte fact par (jqoar* foot) (baud window is closed, or fits when it is closed, has considerable influence on the leakage. The leakage will be high if the Wind YetoaSr, M3* per Hoar are short, if die meeting rail members are warped, or Type of Waff if the frame and sash are not fitted squarely to each other. 5 10 15 20 25 30 It is possible to have a window with approximately the average - crack and clearance that will have a leakage at Brick Wall* least double that of the figures shown. Values for the average 8H io- Plain 2 4 8 12 19 23 double-hung wood window in Table 2 are considered to be easily obtainable figures, provided the workmanship Plastered* 0.02 0.04 0.07 0.11 0.16 0.24 on the window is good. Should it be known that the windows Plain 1 4 7 12 16 21 under consideration are poorly fitted, the larger leakage 13 in. Plastered* 0.01 0.01 0.03 0.04 0.07 0.10 values should be used. Locking a window generally decreases its leakage, but in some cases may push the meeting rail Plastered4 0.03 0.10 0.21 0.36 0.63 0.72 members apart nH increase the leakage. On windows with Frame Wall, lath and plas 0.03 0.07 0.13 0.18 0.23 0.26 large clearances, locking will usually reduce the leakage. ter* Wood casement windows may be assumed to have the same unit leakage as for the average double-hung wood window when properly fitted. Locking, a normal operation In the rinsing of this type of window, maintains the crack at a low value. For a metal pivoted sash, the length of crack is the total perimeter of the movable or ventilating sections. Frame * Tbe nlm fires in this table an 30 pemeut 1cm then teat rmlae* to aUo* tor hnilrfing up c4 perwnrs in rooms, and era baaed on test data reported in tto papers listed in chapter footnotes. * Constructed at poious brick and 1TM* inintri wnrVininiTiip poor. * Two coats prepared (jpsuro H--on brick. 4 Furring, lath, and two coats prepared gypmm piaster on bride. * Wall ecinstt uctfaa: beeel or eedar ins paper, wood lath, and three coats gypsum ptwter. , sheathing, build- leakage on steel windows may be neglected when they are properly grouted with cement mortar into brick work or concrete. When they are not properly sealed, the linear feet of sash section in contact with steel work at mulhons should be figured at 25 percent of the values given in Table 2 for industrial pivoted windows. When storm ash are applied to well fitted windows, some reduction in infiltration is secured; the application of the sash provides an air space which reduces the heat trans^ mission and helps prevent the frosting of the windows.0 By applying storm sash to poorly fitted windows, a reduction in leakage of 50 percent may be obtained, the effect, so far. as air leakage is concerned, being roughly equivalent to that obtained by the installation of weatherstrips. with an air space between them. The infiltration indicated in Fig. 4 is that determined in the laboratory, and should be multiplied by the factor 0.80 to give values consistent with .-Table 3. In order to find air leakage rates from Table 3 re sulting from pressure due to stack action the procedure out lined under Air Leakage Through Windows can be followed. Published data are not available for air leakage rates through modem curtain wall constructions. These no doubt vary considerably in initial tightness as well as in tightness in years following construction. Maximum air leakage rates may. be specified by architects in the design of large commercial buildings. Air Leakage Through Doors Air Leakage Through Walls Infiltration through doors must be considered in relation Data on infiltration through brick and frame walls are given in Table 3.u The brick walls listed in this table are walls that show poor workmanship, and which are con structed of porous brick and lime mortar. For good work manship, the leakage through hard brick walls with cementlime mortar does not exceed one-third the values given. These tests indicate that plastering reduces the leakage by to the type of door and room or building involved. For residences and small buildings where doors are used infre quently, infiltration can be based on the air leakage through cracks between door and frame. Such doors vary greatly in * fit because of their tendency to warp. For a well fitted door, the leakage values for a poorly fitted double-hung wood win dow may be used. If poorly fitted, twice this figureshouid be about 96 percent; a heavy coat of cold water paint, 50 per cent; and three coats of oil paint .carefully applied, 28 per cent. The infiltration through walls ranges from 6 to 25 percent of that through windows and doors in a 10-story office building, with imperfect sealing of plaster at the base boards of the rooms. With perfect wiling the range is from 0.5 to 2.7 percent; or a practically negligible quantity, which indicates the importance of good workmanship for proper sealing at the baseboard. It will be noted from Table 3 that the infiltration through properly plastered walls can be neglected. The value of budding paper, when applied between sheathing and shingles, is indicated by curve 3D-7D, Fig. 4, which represents the effects on outside construction only, without lath and plaster. The effectiveness of plaster prop erly applied is no justification for the use of low grade building paper, or of the poor construction of the wall con taining it. Not only is it difficult to secure and maintain the full effectiveness of the plaster, but also it is highly de sirable to have two points of high resistance to air flow Rg. 4 .,.. infiltration Through Various Types of Shingle Construction Infiltration and Ventilation 461 Rg. 5 .... Design Chart for Evaluating Air Infiltration Rate Through Swinging Door Entrances' Under Winter Heating Conditions used. If weatherstripped, the values may be reduced one-half. A,angle door that is frequently opened, as might be the case in a small store, should have a value applied three times that for a well fitted door. This extra allowance is for opening and dosing loeses, and is kept from being greater by the fact that doors are not used as much in the coldest and windiest weather.- large.rates of leakage can occur with doors in use and this must.be taken into account in commercial establish- ittentB where high traffic rates are expected. Information on we infiltration characteristics of swinging and revolving doors has been quite limited14 and predictions for purposes of toad calculations generally have been a matter of engineering judgment.14 A recent program of Society research has pro vided comprehensive data on the air leakage characteristics of swinging door entrances4 and similar data-on revolving 00r8;" Complementary data on pressure differences across entrances of tall buildings1 have also been provided.. Swinging Door Entrances Air leakage through swinging door entrances is complicated by the opening and closing of doors and other variables re lated to the entrance. Based on a recent research* a simplified chart17 for design purpose is shown in Fig. 5 The infiltration can be evaluated by following the flow diagram if height of building, inside-outside temperature difference, net supply or exhaust air change, type of entrance and traffic rate' are known. Example 1 illustrates the use of the chart.' Example t: A conventional .building 350 ft high'has :a"net cubage of 4,200,000 cu ft. Fresh air fans supply outside air.at the rate of 80,000 cfm and exhaust fans, discharge 50,000.cfm. The building a vestibule-type entrance having.four 3 X 7 ft doors and the indoor temperature is maintained at 75 F. Find the infil tration rate through the entrance at a time when:the traffic'rate 5a 2000 persons per hour. Outdoor temperature is 0;F.-rij,;ijifin; Solution; From Fig. 5A; the theoretical draft, for.,a 350 ft