Document e1yO8MKx3jg0oZQvLpg5BMvv4

r f * Mr, J. 8* Hoitaway AMERICAN BRAKE SHOE COMPANY AMERICAN BRAKE3L0K DIVISION WINCHESTER, VIRGINIA September 10, 1959 Mr. D K. Rennie Troy Office Dear Dons h Js'if AMERICAN BRAKE SHOE CO. medical dept. With regard to yoor letter of August 18, 1959* on the matter of Liberty Mutual * s Industrial Hygiene Survey, conducted June 25 and 26, 1959, ve wish to offer the following* Upon receipt of the report, Messers* C.B. Mallory, J*W* Riley, C.L. Curtis and the writer, made a complete analysis of same* Although ve felt that ve were aware of exact locations as described in the report, there were some areas ve questioned and ve elected to withhold any comments until after such a time as Mr* Charles Cole, Liberty representative, visited us again. Mr. Cole was hare on Friday, September *+, 1959* . Alabama Lead Conclusions (Page 3) 1*) The weighing of certain powders at the south end of the dry mix powder bias indicated high lead concentration (V.33 Milligrams per cubic meter). Observation of this operation indicated the followings (a) Operation is being performed several feet away from the exhaust system. Ibis exhaust was Installed after our Medical Department survey of November 5*8, 1957* (b) Certain new materials are being weighed and there are not sufficient storage bins in regular line to accomodate them* (a) Move weighing operation bade under hood in order that proper advantage may be taken of exhaust system* (b) Relocate exhaust hood in order to use to better advantage. On this item Shop Requisition #22015 has been issued* SCF-ABEX'O^ SPNY 007417 ABEX-067 . Ihe dumping of tr.ir into buggy *; ';.o bot"om of tar? ribh:u Bilker3 on the dry line results jifinss*' not being conisines 'ey the dust control system.. ir.co r= rv.lsiiitn #22016 has been issuod ire: (a) enclose *b.e Rapid iisaderdp Conveyor (b) to pre^id? back on cos? scod on 3-2 line (c) to rework tne boon on -1 line. Borderline health hazard daring dumping Iron bleader ~o 1 iiaamarmlil nay exist. Shop requisition #22017 has been issued to cover a velocity check on the exhaust system here. It Is possible we nay have to throttle back the blast gates mentioned in para. #2 to provide more air here* 4.) Ho comments - based on their comments. Bolling 5c) Minimal concentrations of airborne lead exist at rolling machines except backing machine #6. (a) It is apparent that several conditions exist in the fume hood system! due to "poor* maintenance* This is not entirely the fault of poor workmanship but more from the absence of work performed on the equipment. te.ttgn.Jte.teft Shop requisition #22020 has been Issued to; (a) (b) (c) (d) . Check the fan for BPH's and speed up if. necessary. Relocate several hoods and "fasten with a purpose". Secure "compressed air" signs properly. Repair machine hopper before a complete new one is required. Rtrtn Finishing 6. ) No comments - Everything seems to be in order. 7. ) Close surveillance of exhaust system where higher lead con centrations existed (0.1 milligrams) - Automatic Chamfer #2 * back grinder #3 and exhaust of lorit Collector on automatic strip grinder. SPNY 007418 V 1~ action-Sakea Shop roquistion #20221 has been issued tcs (a) Bebalance dust collector system #1* (b) Pipe lorit Collector to 9ao outside. ~t nus'- he noted that when dust collector #13 is ixstell^i. nr. `additional 4,000 CFi>I*s will be released for vsa in "'is aepartnsr.to 0*4 blots (Blok Department) 9* J No comments - Everything apparently in order 1C i No comments - Everything apparently in order. NOTE* By taking action as indicated above. It is felt we will reduce and in some Instances eliminate those excessive counts as shown on pages 8 ft 9 & 10 of the survey. Airborne Aabestoa Conclusions (Page #11) 1.) Borderline health hazard exists at weigh azad dumping stations in the vet line. Action Taken Shop requisition #22019 has been Issued fori (a) New rubber gaskets on flanges of hopper# (b) New dust "box skirt3* be Installed in place of battered and crushed ones now in use. 2.) Weighing and blander charging - excessive airborne asbestos. Action Taken Shop requisition #22023 has been Issued to cover. Improve design of hoods, rebalance system and relocation, if necessary. 3) Covered above. NOTEt The above action fthnid reduce and/or eliminate high counts shown on page l1* of report. Methrl Ethyl Ketone Vapor la Air VSL BSBfiTftMKfr 1.) No comment. (Page #15) SPNY 007419 (a) Shop requisition ,`,*22024 has been issusa to set: large roof fan to bring air into ream las lead of pulling out - tha latter being operator's desire. Blok Cement Compounding ` 2) Mo comments* 4a) No comments* NOTE: High counts as noted on page 17 should be relieved and/or eliminated as result of above action* Having Conservation Survey No comments. Ventilation Sta^v Oils report indicates that our present system could stand some repairs and revamping. Certain cases exist where the original hood was taken off and never remodeled or replaced* Mr. Wagner's report Indicates that we should redesign our entrance fittings on the majority of our equipment* To do so will be very costly and time consuming and will not in the end solve many problems* We have to assume that the individual workman will still "doctor" or batter the ductwork as they have done in the past* Our control over this will have to be improved upon by going to disciplinary action, if necessary* Hr. Cole was advised that after ve have completed all action of the discussed items we would like him to recheck the areas concerned and again offer their comments. Any comments you may have as to our action on any of these items will be appreciated* W*H*Baker/pr cci F.E.Tayler J.Soviak J*T< Gresh G.A..Riley L.E.Hamlln J*S*Eoltaway SPNY 007420