Document e1orn7a5ZqzBbMLQq841Xe3m

CN K7C ncv UM CSTUUMCS lift E. I. duPont de Nemours & Company INC0*0ATtD WILMINGTON. DELAWARE 19898 ENGINEERING DEPARTMENT CC: A. Francis-CR 701 S. S. Mileti-CR&D-Haskell Lab J. C. Thompson-PED R. Metzger-PED P. W. Hufnell-PED L. O. Barton-PED S. Costa-PED J. B. Arant-ESD D. M. Croskery-ESD IC 13/Maint Engrg December 6, 1985 J. C. THOMPSON ENGINEERING DEPARTMENT L-3205 NONASBESTOS GASKET RECOMMENDATIONS Results of the Company-wide nonasbestos gasket survey completed in June 1985 are: No. of Sites 73 11 17 Status Using asbestos gaskets Using nonasbestos gaskets Not returned The eleven plants using nonasbestos gaskets are small plants with limited gasket usage. I am contacting coordinators on each plant for the purposes of reviewing current product and service indexes, and making nonasbestos gasket code recommendations. Ten plants have been completed. If you want recommendations, please send me the pipe specification number for your site. In the interim, please consider the following when evaluating nonasbestos sheet gaskets. We recommend replacing Du Pont codes G-1, G-2, and G-40 gaskets with codes G-81 and G-83 gaskets only after evaluating chemical resistance of the new gaskets. Where no performance history exists, we recommend either immersion testing or in-line testing of G-83 gasket material to determine chemical resistance. While some of these tests can be done at the Engineering Test Center, we feel that they should be done on plant sites. This eliminates DUP 1011080 GEC9A:4 DU 053122 2 December 6, 1985 Nonasbestos Gasket Recommendations interstate transportation of hazardous chemicals. It also ensures testing will be done by people familar with the hazards of the chemicals being used. Gasket codes G-83/S-83 describe Kevlar* reinforced gaskets/sheet bonded with EPDM. Code S-83 is a better replacement choice than S-80 (SBR bonded Kevlar*) because: o Continuous temperature resistance of EPDM (325*F) is higher than SBR (225*F). o EPDM has wider chemical resistance than SBR. o Code S-83 contains fewer chlorides. Replacing G-1 gaskets with G-80 gaskets is the more obvious, but not necessarily the best option. Gaskets G-80 and G-1 both use SBR binder. However, reinforcing fiber differs with G-80 gaskets having lower concentrations of fiber (20%) and higher concen trations of elastomer binder and inert fillers than G-1. In many past installations, G-1 gaskets worked only because of high concentrations (85%) of asbestos fibers and not because of chemical resistance of the binder. G-83 gaskets are 5% more than G-80 gaskets, but Du Pont supplies both Kevlar* and EPDM. Do not .replace G-1 gaskets with G-80 gaskets without first determining chemical resistance by immersion or in-line testing, similar to tests recommended for G-83. In a limited group of chemicals, G-82 (neoprene bonded Kevlar*) may show wider chemical resistance than G-83, especially when oils or Freon* are included. However, laboratory tests of various G-82 gaskets show total chloride levels of 35,000 to 60,000 ppm. Chlorine is used in the manufacture of neoprene so G-82 gaskets will always have high chlorides. To prevent chloride stress cracking in stainless steel piping systems, maximum gasket chloride levels are usually set at 250 ppm. We do not recommend using any type of neoprene gaskets to reduce chances of chloride stress cracking if the gaskets are inadvertently used in stainless steel flanges. Neoprene also has poor ozone resistance. G-81 (Nitrile Butadiene Rubber (NBR) bound Kevlar*) gaskets are preferred for most oil, natural gas, hydrocarbon, and Freon* lines. EPDM used in G^83 gaskets will swell in these services. We are still determining whether swellinq results in gasket deterioration or improves gasket seaLability. In summary, replacement of G-1, G-2, and G-40 gaskets is ideally accomplished with two gasket codes (G-83 and G-81). For plant sites insisting on using only one fiber reinforced sheet gasket, we recommend evaluating G-81. Code G-81 provides good hydrocarbon resistance and average temperature resistance, but vsovvov ana GEC9A:3 DU 053123 3 December 6, 1985 Nonasbestos Gasket Recommendations still requires chemical resistance testing. Use only gasket styles listed in Engineeering Specifiction SU-2A. Edge Moor uses plastic coated tags to mark the location of nonasbestos gaskets undergoing in-line testing. Tags are available from Story Printing. Contact Ben Cohen on (302) 655-4455. 1 Table 1 lists "m" and "y" values for various nonasbestos gaskets manufactured by Garlock. Seating stress ("y") is the force required to initially seal a gasket before process pressure is applied. "Y" values for all nonasbestos gaskets are higher than "y" values for asbestos gaskets listed in the ASME Boiler Pressure Vessel Code. However, Garlock has retested Style 9532 asbestos sheet qasket (G-1) and found the "y" value (seating stress) to be in the same range as nonasbestos substitutes. Please copy me on any significant correspondence regarding the transition from asbestos to nonasbestos gaskets. Feel free to call me on 366-4200 if there are any additional questions. ENGINEERING SERVICE DIVISION h 2. G. E. Colalillo Maintenance Engineering Group GEC:mer Enclosure OVJP 1011082 GEC9A:3 DU 053124 TABLE 1 "m" AND "y" FACTORS FOR COMPRESSED NONASBESTOS AND GYLON GASKETS PROCEDURE MATERIAL DIN3535 Compressed Asbestos DIN3535 Compressed Nonasbestos DIN3535 Compressed Nonasbestos CODE GARLOCK NO. THICKNESS m y G-1 9532 1/32 1/16 1/8 3.0 2800 5.6 3400 6.5 4800 G-80 3200 & 3400 1/32 1/16 1/8 3.5 2400 4.0 2600 6.6 3000 - 3000 1/32 1/16 1/8 3.5 2600 4.8 3000 6.6 3400 DIN3535 Compressed Nonasbestos G-81 3001 Data Not Available DIN3535 Compressed Nonasbestos G-82 3300 1/32 1/16 1/8 3.2 12.4 15.3 2800 5600 7600 DIN3535 .. Compressed Nonasbestos G-83 3700 1/32 1/16 1/8 2.5 2800 3.0 3200 6.7 4200 ASTM F-586 Compressed Asbestos G-1 9532 Data Not Available To be supplied soon ASTM F-586 Filled Teflon (Fawn) 3500 1/32 1/16 1/8 7.3 8.0 14.5 5600 6000 10000 ASTM F-586 Filled Teflon (Off-white) G-49H 3510 1/32 1/16 1/8 2.0 3400 2.0 3400 2.0 3400 ASTM F-586 ASTM F-586 ASTM F-586 Filled Teflon (Blue) 3504 Flexible Graphite S-1 3 (homogeneous sheet) Graphlock Flexible Graphite S-13W Graphlock (wire inserted) 1/32 1/16 1/8 1/32 1/16 *1/8 1/32 1/16 *1/8 2.5 3000 1.8 2500 2.5 3000 2.0 2000 2.0 2500 2.0 2500 2.0 2200 2.0 2500 2.0 2500 *Not recommended - too thick for good sealability through sheet. GEC9A: 5` q c U O Oco w DU 053125 C N- 102t tv S i ouiuM(ee) E. I. du Pont de Nemours & Company IMCO0<ATtP Wilmington, Delaware 19898 CC: D.M. Croskery/M.C. Hewitl-ESD L.J. Kitchens-ESD IC 13-Maint. Engg. ENGINEERING DEPARTMENT LOUVIERS BUILDING October 3, 1985 DENNIS ST0RDAJ4L-------- textile fibers department SEAFORD To AVI Usl-a^TH^ s* r z &t t rt&` I NON-ASBESTOS GASKET RECOMMENDATIONS IDENTIFICATION OF PRODUCT AND SERVICES In order to make non-asbestos gasket recommendations, please identify the Following product or services found on Piping Specification 4225, Section 2. Item 4 5 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Product or Service Additive Solution 300 Additive Type 826 DRL-6....... - Finish Solution Finish, Agent 305 Finish, Agent 314 Finish, Agent 365 Finish, Agent 395 Finish, Agent 436 Finish, Flake 361 Finish, Ingredient 313 Finish, Liquid 306 Finish, Liquid 326 Finish, Liquid 327 Finish, Liquid 328 Finish, Liquid 337 Finish, Liquid 364 Finish, Liquid 366 Finish, Liquid 368 Finish, Liquid 391 Finish, Liquid 394 Finish, Liquid 396 Finish, Liquid 441 Finish, Primary Finish, Secondary Finish, Spinning Machine Primary Finish, Spinning Machine Seconder Finish, Waste Drains Finisher to Hot Well Flake Conditioning DUP 1011084 DU 053126 2 October 3, 1985 Denn:s Stordahl 11 em 70 77 78 84 85 86 87 88 89 90 91 92 93 96 97 Product or Service Inert Gas Liquid 565 Miscellaneous Waste NRD 2 5 NRD 254 Salt Solution NRD 47 Liquid NRD 52 and NRD 43 NRD 54 Liquid NRD 59 Additive Solution NRD 70 Anti-Stat NRD 29 Solution after Injection Pump NRD 29 Solution before Injection Pu^p Nylon - 10055 Salt Nylon Polymer Nylon Polymer, Reaction Vessel of flasher Feed Pumps Please identify type of gaskets used for items Number 176 and 177, now specified for Johns-Manvi1le Number 92 B 4 8 (i.e., asbestos, elastomer, etc.'/.' ....... If there are any further questions, please call me on 366-4200. ENGINEERING SERVICE DIVISION Gregory E. Colalillo Maintenance Engineering Group GEC : tmt GEC7A:19 DUP 1011085 DU 053127 '-' i ?'r-~ 1 ir* i K 1,8 ,s '|latiS f If:'K Ie'J. n-.il3ft fi.OTfiff' c**>iai cv t-u E. I. du Pont de Nemours & Company Wilmington. Delaware 19898 CNCINCCKINa oepamtmcnt LOUVICKS UILDING October 3, 1985 CC: D.M. Croskery/M.C. Hewitt-ESD L.J. Kitchens-ESD IC 13-Maint. Engg. DENNIS STORDJLRt--------TEXTILE FIBERS DEPARTMENT SEAFORD NON-ASBESTOS GASKET RECOMMENDATIONS IDENTIFICATION OF PRODUCT AND SERVICES In order to make non-asbestos gasket recommendations, please identify the following product or services found on Piping Specification 4225, Section 2. Item 4 5 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 Product or Service Additive Solution 300 "''Additive Type 826 DRL 6 Finish' Solution Finish, Agent 305 Finish, Agent 314 Finish, Agent 365 Finiah, Agent 395 Finish, Agent 436 Finish, Flake 361 -"Finish, Ingredient 313 `"'Finish, Liquid 306 Finish, Liquid 326 Finish, Liquid 327 Finish, Liquid 328 Finish, Liquid 337 Finish, Liquid 364 Finish, Liquid 366 Finish, Liquid 368 Finish, Liquid 391. Finish, Liquid 394 Finish, Liquid 396 Finish, Liquid 441 Finish, Primary ^Finish, Secondary ."Finish, Spinning Machine Primary -"Finish, Spinning Machine Secondary "Finish, Waste Drains ^-Finisher to Hot Well Flake Conditioning DUP 1011086 DU 053128 2 October 3, 1983 Dennis Stordahl Item 70 77 78 84 83 86 87 88 89 90 91 92 93 96 97 Product or Service Inert Gas Liquid 363 Miscellaneous Waste NRD 25 ^NRD 254 Salt Solution NRD 47 Liquid HIRD 52 and NRD 43 u^NRD 54 Liquid t/ftRD 59 Additive Solution-NRD 70 Anti-Stat ^-NRD 29 Solution after Injection Pump ''foRD 29 Solution before Injection Pump Nylon - 100S Salt Nylon Polymer ^,Nylon Polymer, Reaction Vessel of flasher feed Pumps Please identify type of gaskets used for items Number 176 and 177, now specified for Johns-Manville Number 92 B & B (i.e., asbestos, elastomer, etc.). If there are any further questions, please call me on 366-4200. ENGINEERING SERVICE DIVISION y. Cc&Jddi Gregory E. Colalillo Maintenance Engineering Group GEC:tmt GEC7A:19 i8 0 u o t dna DU 053129