Caid No of 3 on operation of Aroclor 1248 heal transfer by',terns
SYSTEMS
Observe the manufacturers' recommendations for maintaining all equipment in the system and watch these additional points;
Q Keep all t
tihrk-'Ued.
B Routinely < heck
.... = .f : JlldijsL? shown by safety and
temperature limit controls.
Q Periodically c !iec k burner, refractory li lings),
. theater tubes.
Q Keep heater
and iu' I filters cleat
Q ( heck nalcr cnoliin; of the circulation pump.
Q Repack stuffing hoves as needed, according to supplier's recommendations.
Aroclor Check-up
Aroclor 1248 is very stable when properly used. Its condition is indicated by its viscosity (see Fig. 6 of Monsanto's booklet, "Aroclor 1248 Heat Transfer Data").
Once or twice a year take .t sample of the circulating Aroclor fluid and make a viscosity determination. Most plants have the simple equipment needed for this operation. Others send it to an outside laboratory, The fluid will be checked free of charge if a .ine-qn.trt sample properly packed is shipped to
MONSANTO CHEMICAL COMPANY Organic Chemicals Division Industrial Fluids Sales P. O. Bo* 478 St. Louis. Missouri
In systems operating normally at temperatures not over bOCTF. and not subject to frequent power failures (with consequent overheating of fluid), an annual check of the circulating fluid is usually sufficient.