Document e1Vp3zwORr8NeOR55Zxe3aVvm
Training & Development Procedures
Chlorinated Methaogs
CMP PROCEDURE TECH NOVA LIQUID SAMPLER
PURPOSE
Sampling procedure using the TECH NOVA sampler.
SCOPE
This procedure will instruct you on the correct way to sample process streams that are equipped with TECH NOVA samplers.
RELATED PROCEDURES
Sampling policy for gas and liquid samples, waste disposal policy.
DEFINITIONS
TECH NOVA Sampler This is the name of the sampling device used for catching a process samples.
SAFETY CONCERNS & EQUIPMENT
THERMAL: This sample point may at times have a high or low temperature, so when catching this sample use necessary precaution as to prevent skin contact. Use gloves when sampling.
CHEMICAL: Remember you are working with chemicals that may cause skin and eye irritation.
MECHANICAL: Use caution when working with cylinders that be under pressure.
ENVIRONMENTAL CONCERNS
With the use of a Tech Nova sampler there should be no emissions to the atmosphere if everything is working properly.
SPECIAL CONCERNS
Tech Nova Sample Cylinder should be emptied after sample analysis is complete.
PROCEDURE RECOMMENDATIONS
If a procedure is currendy active at relief, state in the relief notes the status off the job and the steps that have been completed up to this point.
Highlight the procedure steps as they are completed so operations personnel are aware of its status. This is especially important during shift relief when jobs are incomplete.
Avoid carryover of a job when possible. I.E. Starting a Job at 5:00 AM/PM, just prior to relief.
CONFTDFNTJAlDow Confidential This procedure is only valid from 24 hours of its viewing date, August 22, 1997,1:27 PM
oo 008086
Training & Development Procedures
Chlorinated Methanes
TECH NOVA LIQUID SAMPLER
PROCEDURE
Step 1 2 3
4
5 6 7 8 9
Action
Make sure the Technova Valve in the line is completely closed before removing the safety sealing plug.
Install the sample cylinder into the Technova Valve and then rotate the cylinder to insure a snug fit Tighten the lock screw to secure the cylinder.
With the cylinder installed, open the valve on the cylinder by rotating the rear valve handle counter clock wise.
If a protective shield is installed for this sample point close shield before going on to step four.
Now open the in-line valve by depressing the spring loaded handle, or if equipped with a remote switch, rotate switch to the open position. You will see the large wheel on the sample cylinder begin to rotate, this will indicate that sample is filling the cylinder.
Once the cylinder is about 3/4 filled, release the spring loaded handle, or if equipped with a remote switch, rotate switch to close position, to stop filling the cylinder.
Now block in the needle valve on the sample cylinder by rotating the handle clockwise.
After all valves are closed loosen the locking screw and remove the sample cylinder and replace the sealing plug.
Return the sample to the lab for analysis.
Dispose of unused sample when analysis is completed.
OONFTDFNTTAL 00 008087
Training & Development Procedures
Chlorinated Methanes
TECH NOVA LIQUID SAMPLER
Document Control and History
Note: To Automatically Update the following fields, Go to Edit menu and choose "Select All", Press F9
File Name
Tech Nova Liquid Sampler.doc
Created By
TERRY VAVASSUER
Creation Date
05/29/97 10:42 AM
Last Saved By
Gary Rizzo
Last Saved Date
05/29/97 10:46 AM
Last Print Date
08/22/97 1:27 PM
Location of
This procedure will be located in the LANT51 Methproc/Procedures
Controlled Copies
Revision History
CONFIDFNTTAl DO 008088
Training & Develonment Procedures___________________
Chlorinated Methanes
CMP PROCEDURE
__________ACID AREA SAFETY EQUIPMENT REQUIREMENTS
PURPOSE
To provide a document which will state the safety equipment required in the different acid area's throughout the plant.
SCOPE
Same as above
RELATED PROCEDURES DEFINITIONS
SPECIAL CONCERNS
Sulfuric Acid Lines and Equipment Requiring Elevated Work.
Walk Through = No work will be taking place in this area "Working On =s Any operation of valves or equipment in the area. This also includes line openings, checking bleeds, trouble shooting equipment where any type of opening is required, etc. These are the minimum requirements.
PROCEDURE RECOMMENDATIONS
If a procedure is currently active at relief, state in the relief notes the status off the job and the steps that have been completed up to this point.
Highlight the procedure steps as they are completed so operations personnel are aware of its status. This is especially important during shift relief when jobs arc incomplete.
Avoid carryover of a job when possible. I.E. Starting a Job at 5:00 AM/PM, just prior to relief.
CONF^NTTAl
00 008089
Dow Confidential This procedure is only valid for 24 hours of date viewed, August 22, 1997, 11:00 AM
Training & DevelopmentProceduresChlorinated Methanes ACID AREA SAFETY EQUIPMENT REQUIREMENTS
Requirements A full acid suit is required to do any type of work on ground level around H2S04 acid pumps. Any deviation from this requires plant superintendent approval.
To do work on instrumentation in areas requiring a full acid suit to be wom, the thin rubber gloves are permitted.
For any elevated work on lines or equipment which would require an acid suit, see procedure "Sulfuric acid lines and equipment requiring elevated work."
AREA C-202 Btms
E-212 C-650 Btms T-651 Btms H2S04T/C
Rack (Car Connected) T-900 C-202 Decks C-650 Decks T-651 Deck H2S04 T/C Rack (Car Not Connected) C-210
C-200 / C-201 Btms
P-301's
C-610 C-600
MEASUREMENS WALK-THRU Slicker Suit / Goggles/ Rubber Boots,
Gloves Same As Above Same As Above Same As Above Same As Above
WORKING ON Full Acid Suit. Where elevated work is
not required Same As Above Same As Above Same As Above Same As Above
Same As Above Goggles Goggles Goggles Goggles
Goggles
Goggles
Goggles
Goggles Goggles
Same As Above Same As Above Same As Above Same As Above Goggles (Except When Working On H2S04 Lines)
Slicker Suit / Goggles/ Rubber Boots, Gloves
Same as above
Slicker Suit / Goggles/ Rubber Boots, Gloves
Same As Above Same As Above
CONFTDFN-nAl
00 008090
Training & Development Procedures______________ ____ ___________ Chlorinated Methanes
ACID AREA SAFETY EQUIPMENT REQUIREMENTS
AREA
C-200/C-201 / C-210 C-600 C-650
H2S04 TIC C-202 Btms.
CATCHING SAMPLES SAFETY EQUIPMENT
Slicker Suit / Goggles / Rubber Boots / Gloves Same As Above Full Acid Suit Same As Above Same As Above