Training & Development Procedures Chlorinated Methaogs CMP PROCEDURE TECH NOVA LIQUID SAMPLER PURPOSE Sampling procedure using the TECH NOVA sampler. SCOPE This procedure will instruct you on the correct way to sample process streams that are equipped with TECH NOVA samplers. RELATED PROCEDURES Sampling policy for gas and liquid samples, waste disposal policy. DEFINITIONS TECH NOVA Sampler This is the name of the sampling device used for catching a process samples. SAFETY CONCERNS & EQUIPMENT THERMAL: This sample point may at times have a high or low temperature, so when catching this sample use necessary precaution as to prevent skin contact. Use gloves when sampling. CHEMICAL: Remember you are working with chemicals that may cause skin and eye irritation. MECHANICAL: Use caution when working with cylinders that be under pressure. ENVIRONMENTAL CONCERNS With the use of a Tech Nova sampler there should be no emissions to the atmosphere if everything is working properly. SPECIAL CONCERNS Tech Nova Sample Cylinder should be emptied after sample analysis is complete. PROCEDURE RECOMMENDATIONS If a procedure is currendy active at relief, state in the relief notes the status off the job and the steps that have been completed up to this point. Highlight the procedure steps as they are completed so operations personnel are aware of its status. This is especially important during shift relief when jobs are incomplete. Avoid carryover of a job when possible. I.E. Starting a Job at 5:00 AM/PM, just prior to relief. CONFTDFNTJAlDow Confidential This procedure is only valid from 24 hours of its viewing date, August 22, 1997,1:27 PM oo 008086 Training & Development Procedures Chlorinated Methanes TECH NOVA LIQUID SAMPLER PROCEDURE Step 1 2 3 4 5 6 7 8 9 Action Make sure the Technova Valve in the line is completely closed before removing the safety sealing plug. Install the sample cylinder into the Technova Valve and then rotate the cylinder to insure a snug fit Tighten the lock screw to secure the cylinder. With the cylinder installed, open the valve on the cylinder by rotating the rear valve handle counter clock wise. If a protective shield is installed for this sample point close shield before going on to step four. Now open the in-line valve by depressing the spring loaded handle, or if equipped with a remote switch, rotate switch to the open position. You will see the large wheel on the sample cylinder begin to rotate, this will indicate that sample is filling the cylinder. Once the cylinder is about 3/4 filled, release the spring loaded handle, or if equipped with a remote switch, rotate switch to close position, to stop filling the cylinder. Now block in the needle valve on the sample cylinder by rotating the handle clockwise. After all valves are closed loosen the locking screw and remove the sample cylinder and replace the sealing plug. Return the sample to the lab for analysis. Dispose of unused sample when analysis is completed. OONFTDFNTTAL 00 008087 Training & Development Procedures Chlorinated Methanes TECH NOVA LIQUID SAMPLER Document Control and History Note: To Automatically Update the following fields, Go to Edit menu and choose "Select All", Press F9 File Name Tech Nova Liquid Sampler.doc Created By TERRY VAVASSUER Creation Date 05/29/97 10:42 AM Last Saved By Gary Rizzo Last Saved Date 05/29/97 10:46 AM Last Print Date 08/22/97 1:27 PM Location of This procedure will be located in the LANT51 Methproc/Procedures Controlled Copies Revision History CONFIDFNTTAl DO 008088 Training & Develonment Procedures___________________ Chlorinated Methanes CMP PROCEDURE __________ACID AREA SAFETY EQUIPMENT REQUIREMENTS PURPOSE To provide a document which will state the safety equipment required in the different acid area's throughout the plant. SCOPE Same as above RELATED PROCEDURES DEFINITIONS SPECIAL CONCERNS Sulfuric Acid Lines and Equipment Requiring Elevated Work. Walk Through = No work will be taking place in this area "Working On =s Any operation of valves or equipment in the area. This also includes line openings, checking bleeds, trouble shooting equipment where any type of opening is required, etc. These are the minimum requirements. PROCEDURE RECOMMENDATIONS If a procedure is currently active at relief, state in the relief notes the status off the job and the steps that have been completed up to this point. Highlight the procedure steps as they are completed so operations personnel are aware of its status. This is especially important during shift relief when jobs arc incomplete. Avoid carryover of a job when possible. I.E. Starting a Job at 5:00 AM/PM, just prior to relief. CONF^NTTAl 00 008089 Dow Confidential This procedure is only valid for 24 hours of date viewed, August 22, 1997, 11:00 AM Training & DevelopmentProceduresChlorinated Methanes ACID AREA SAFETY EQUIPMENT REQUIREMENTS Requirements A full acid suit is required to do any type of work on ground level around H2S04 acid pumps. Any deviation from this requires plant superintendent approval. To do work on instrumentation in areas requiring a full acid suit to be wom, the thin rubber gloves are permitted. For any elevated work on lines or equipment which would require an acid suit, see procedure "Sulfuric acid lines and equipment requiring elevated work." AREA C-202 Btms E-212 C-650 Btms T-651 Btms H2S04T/C Rack (Car Connected) T-900 C-202 Decks C-650 Decks T-651 Deck H2S04 T/C Rack (Car Not Connected) C-210 C-200 / C-201 Btms P-301's C-610 C-600 MEASUREMENS WALK-THRU Slicker Suit / Goggles/ Rubber Boots, Gloves Same As Above Same As Above Same As Above Same As Above WORKING ON Full Acid Suit. Where elevated work is not required Same As Above Same As Above Same As Above Same As Above Same As Above Goggles Goggles Goggles Goggles Goggles Goggles Goggles Goggles Goggles Same As Above Same As Above Same As Above Same As Above Goggles (Except When Working On H2S04 Lines) Slicker Suit / Goggles/ Rubber Boots, Gloves Same as above Slicker Suit / Goggles/ Rubber Boots, Gloves Same As Above Same As Above CONFTDFN-nAl 00 008090 Training & Development Procedures______________ ____ ___________ Chlorinated Methanes ACID AREA SAFETY EQUIPMENT REQUIREMENTS AREA C-200/C-201 / C-210 C-600 C-650 H2S04 TIC C-202 Btms. CATCHING SAMPLES SAFETY EQUIPMENT Slicker Suit / Goggles / Rubber Boots / Gloves Same As Above Full Acid Suit Same As Above Same As Above CONFTDFNTTAt DO 008091 r