Document dzejJ3qxvxKDQGnYK9ppyBD9

Johns-Manville Refractory S/31 Products Marinite ! 1200F Fireproof Structural insulation Description Marinite I Fireproof Structural Insulation is an incombustible material in 4' X 8' panel form designed to combine structural strength and high thermal insulating values in a variety of fireproofing and heat processing equipment applications up to 1200F. Free of asbestos and formed from calcium silicate with inert fillers and reinforcing agents, Marinite I panels provide structure and insulation in a single, easily erected material. In addition to high strength and excellent thermal insulating characteristics, Marinite I structural insulation is highly damage-resistant, noncorroding, and extremely water-resistant. Marinite I panels also provide fire safety, uniform temperature control, minimal maintenance, and fast, easy fabrication. The airborne particulate generated by the fabrication of Marinite I untreated panels is classified by OSHA standards only as a nuisance dust. Ai'e;:cL>;& Fort,',; Marinite I. With a sanded finish on both sides, is furnished in 46 Ibs/cu. ft. nominal density, in thicknesses of V2" through 2". Marinite l-V. Veneered on both sides with a 0.100"-thick hydrothermally cured asbestos-cement sheets, is furnished in thicknesses of 1" and IV4". Machined Parts Typical Applications Because it is both a structural and an insulating material, Marinite I in full size 4' X 8' panels offers major economic advantages in the construction of ovens, driers, and other insulated housings for the retention and control of heat. Because of its machineability, Marinite I can be readily fabricated into various sizes and shapes for heat baffles and all types of insulating parts. In addition, Marinite I is used in fire safety applications such as fire stops, cable trays, and fire doors, and provides an ideal, incombustible base for melamine veneers. McGCon 2380 Sect. 170 Date: 12-79 Part 09 Cancels: 8-79 Specification Data Marinite i Properties Density, pcf 46 Moisture Content (normal) Percent of Dry Weight * 5 Transverse Strength (dry), psi (Modulus of Rupture) 725 Modulus of Elasticity (dry), psi (From Transverse Test) 300,000 Consolidation Und>::' Load '/norma;':. in./in. Pressure, psi Deflection Under Load Permanent Consolidation 500 1000 2000 3000 4000 5000 6000 0.032 0.058 0.179 0.299 0.366 0.418 0.462 -----0.025 0.132 0.235 0.320 0.369 0.400 Tensile Strength (normal), psi Normal to face of sheet Parallel to face of sheet 55 200 Shear Strength (normal), psi Normal to face of sheet Parallel to face of sheet 1000 405 Brinell Hardness No. (dry) 45.4 kg load, 19.05 mm ball, 15 sec. 1.2 Charpy Impact Resistance, ft.-lb. 5 in. x V2 in. x 7/s in. samples 0.27 Screw Holding Strength (normal), lb. V2 in. penetration % in. penetration 87 208 Dimensional Change Due to Moisture, in./in. Shrinkage--normal to dry Expansion--normal to 90% RH Expansion--dry to saturated 0.0011 0.0013 0.0026 Thermal Expansion, in./in./F (Average over temperature range indicated: shrinkage thereafter) 3.84 x 10-6 up to 300F Standaro Sizes Type Marinite 1 Marinite l-V Thickness, inches V2, %, 1. IV2, 2 %, 1 Sheet size feet 4x8 4x8' Dimensions: Tolerances (inches) Length and Width Thickness Squareness (max. difference between diagonals) --V32 --V32 Ve Thermal Conouc Imitv (Emu-m. sc. rt.' F; I'ii. Temperature F 75 350 400 500 600 700 800 900 1000 k 0.88 0.82 0.81 0.80 0.79 0.80 0.81 0.83 0.86 Specific Heat Temperature F 200 400 600 800 Permeability 8.1 perm-inches Specific Heat Btu/F/lb. 0.28 0.30 0.32 0.34 (normal) refers to normal conditions of 75F and 50% R.H. (dry) refers to oven-drted material' McGCon 2382 Minimum Thickness (inches) of Marinite 1 Required to Provide Indicated Surface Temperature and Heat Loss (with 80F ambient still air) Make final check against Warpage Control Table Operating Temperature, F 200 300 400 500 600 700 800 900 1000 125F Surface Temperature: (Heat Loss: 87 Btu/sq. ft./hr.) % 1% 2% 39/i6 47,6 5% 6'A 7Va 8 150F Surface Temperature: Vi 6 (Heat Loss: 142 Btu/sq. ft./hr.) ,S/l6 V/2 2'/l6 2% 3Va 3'Vi 6 4V4 43/4 175F Surface Temperature: *Vs (Heat Loss: 203 Btu/sq. ft./hr.) Vi 6 'Vl6 1% 1% 2Va 2Vz 2% 3'A 'Minimum available thickness of Marinite I is Vi". Fire Hazard Classification Listed under Underwriters Laboratories Inc. Guide Numbers: Guide No. BQJT Flame Spread* Fuel Contributed Smoke Developed 0 Negligible 0 This numerical flame spread rating is not intended to reflect hazards presented by this or any other material under actual fire conditions. Guide No. CERZ Two hour wall and partition fire resistance rating. Guide No. ZCRW Form board for structural element penetrations in System Nos. 1, 2, 3, 4, 5, 7, 10, 18, 23. Electrics! Properties Marinite I panels possess relatively good electrical insulating properties when dry. Because the material is hygroscopic, however, its electrical resistance is reduced after moisture absorption. As moisture pickup may be expected to cause problems under high-humidity ambient conditions or following the shutdown of equipment, Marinite I panels are not recommended for direct mounting of current-carrying parts. Volume Resistivity (ASTM D257)--taken at 100 volts DC and 1 minute electrafaction time using painted silver electrodes (ohm-cm) Condition 1" Thick Marinite 1 1" Thick Flat Transite 600F--Dry 815 trillion 27,700,000 75F--50% RH 98,300,000 10,500,000 71F--91% RH 3,490,000 4,900,000 .... E iea:\co . i; (ASTM D149)--taken at 500 volts per second rate of rise and 60 HZ. (volts per mil) Condition 1" Thick Marinite 1 1" Thick Flat Transite 600F--Dry 50.5 72F--50% RH 45.3 20.3 3.1 72F--87% RH -- 1.55 72F--90% RH 32.0 -- 72F--93% RH -- Too wet for valid test Despite this stipulation, Marinite I structural insulation is used by some manufacturers for this purpose, particularly at low voltage and at elevated temperatures. The decision to use Marinite I panels for electrical purposes must rest solely with the user. In these applications, it is suggested that protection be provided against electrical shock hazard. The following values compare the electrical properties of Marinite I panels with Flat Transite sheets, a Johns-Manville building panel produced from asbestos cement and used in similar applications. McGCon 2383 l The physical and chemical properties of the Johns-Manville products presented in this brochure represent typical, average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. They are supplied as a technical service and are subject to change without notice. Therefore, the data contained herein should not be used for specification purposes. Check the Johns-Manville district office to assure current information. District Offices Midwest Johns-Manville 2222 Kensington Court Oak Brook, IL 60521 (312)887-7400 North Central Johns-Manville P.O. Box 517 Toledo, OH 43693 (419)878-8111 Northeastern Johns-Manville P. O. Box 1544 600 Sylvan Avenue Englewood Cliffs, NJ 07632 (201)894-1111 Southeast Johns-Manville P.O. Box4487 Atlanta, GA 30302 (404)449-3300 South Central Johns-Manville P.O. Box 1355 (77001) 10900 Northwest Freeway Houston, TX 77092 (713)681-7624 Pacific Southwest Johns-Manville 3701 Long Beach Blvd. Suite 205 Long Beach, CA 90807 (213)428-7515 Pacific Northwest Johns-Manville 2600 Campus Dr. San Mateo, CA 94403 (415)349-9500 Automotive Products Dept. Johns-Manville 32048 Edward Ave. Madison Heights, Ml 48071 (313)585-7835 Zelienople Plant Johns-Manville Refractory Products Dept. Zelienople. PA 16063 (412)452-8650 For Information on other J-M Thermal Insulations and Systems, Write the Johns-Manville Insulation Center, Drawer 17L, Denver, Colorado 80217 or call (303) 979-1000. iiSi Johns-Manville Ken-Caryl Ranch Denver, Colorado 80217 IND-3261 12-79 McGCon 2385 Lrtho r\ USA