Document dnkqXDL54YaVnEGr5xbr59Yze
Boilers
Irvington, N. Y.
Makers of Low Pressure Cast Iron Boilers
Twin Section for heavy duty work. Sections and grates both being twins, con Pass through small opening. No rights and lefts to sections. Three men can set it up.
Burnham Square Sectional boil ers are based on the principle that a long fire travel (correctly pro portioned) reduces fuel bills. The hot gases go back and forth three times the length of the boiler, on each side of the boiler, before they are led to the smoke box opening.
Because of the individual side flue openings, each section absorbs an equal amount of heat.
Burnham steam boilers have such a low water line that they can be used in shallow cellars. They are so constructed that the size of the steam dome is not sacrificed.
Every operating part is handy in front of the boiler.
Every flue has a separate clean out door.
254
TWIN SECTIONAL FOR HEAVY DUTY
Steam Boilers
Number
Crate Area
Sq. Ft.
No. and Size of Outlets
Inlet*
No. and Size of
Safety Valve
Rating Sq.Ft.
S-50-6 S-50-7 S-50-8 S-50-9 S-50-10 5-50-11 S-50-12
W-50-6 W-50-7 W-50-8 W-50-9 W-50-10 W-50-11 W-50-12
19.27
22.92 26.56 30.20
33.85 37.5 41.14
3-5"
3-5" 4-5" 4-5" 4-5"
5-5"
5-5"
3"
3Vl"
3'/i" 3VY'&2" 3i/2"c2"
3,/i" ic 3" 3%"&3"
Water Boilers
19.27
22.92
26.56 30.20
33.85 37.5 41.14
4-5"
4-5" 5-5" 5-5" 5-5" 6-5"
6-5"
6,250 7.425 8,600 9,775 10,950 12,125 13,300
10,300 12,250 14,200 16,150 18,100 20,050 22,000
SQUARE SECTIONAL Steam Boilers
Number
Grate Area
Sq. Ft.
Size Supply
Tap pings
Size Return
Tap
pings
Rating Sq. Ft.
S-18-4 S-18-5 S-18-6 S-18-7 S-24-5 S-24-6 S-24-7 S-24-8 S-30-5 S-30-6 S-30-7 S-30-8 S-30-9 S-36-6 S-36-7 S-36-8 S-36-9 S-36-10 S-36-11
W-18-4 W-18-5 W-18-6 W-18-7 W-24-5 W-24-6 W-24-7 W-24-8 W-30-5 W-306 W-30-7 W-30-8 W-30-9 W-36-6 W-36-7 W-36-8 W-36-9 W-36-10 W-36-II
3.00 -3'/2"
3.94 2-3*A"
4.88 2-3
5.81 2-3'A"
5.17 2-4"
6.42 * 2-4"
7.67 2-4"
8.92
2-4"
6.46 2-4"
8.02- - 2-4"
9.58 2-4"
11.15 3-4"
12.71
3-4"
9.88 2M"
11.75
3-4"
13.63
3-4"
15.50 3-4"
17.38 4-4"
19.25 4-4"
1-3'/2" 2-3'/2" 2-3'A" 2-3'f2"
2-4" 2-4"
2-4" 2-4" ' 2-4" 2-4" 2-4"
2-4" 2-4" 2-4" 2-4" 2-4" 2-4"
2-4" 2-4"
Water Boilers
3.00 3.94 4.88
5.81 5.17 6.42 7.67
8.92 6.46 8.02
9.58 11.15 12.71
9.86 II.75
13.63 15.50 17.38 19.25
2-3'/2" 2-3'A"
1-Wi"
2-4A
2-4" 2-4" 3-4" 2-4" 2-4" 3-4" 3-4" 4-4" 3-4" 3-4" 4-4" 4-4" 5-4" 5-4"
2-3'/2"
2-3'/2" 2-3>/2" 3-3'/2"
2-4" 2-4" 2-4"
3-4" 2-4" 2-4"
3-4" 3-4" 4-4" 3-4"
3-4" 4-4"
4-4" 5-4" 5-4"
750 950 1,150 1,350 1,350 1,700 2,050 2,400 1,750 2,250 2,750 3,250 3,750 2,850 3,500 4,150 4,700 5,350 6.000
1,250 1,575 1,900 2,225 2,225 2.800 3,375 3.950 2,900 3,715 4,530 5,345 6,160 4,700 5,775 6,850 7,925 9,000 10,075
Boilers
General Boilers Company
Manufacturers of
Pacific Steel Heating Boilers, Pacific Circulating Tanks
Waukegan, Illinois
PACIFIC SMOKELESS STEAM BOILERS
Catalog
Num ber
Net Rating
Height Water Line, Inches
Dimen sions
Overall. Inches
Diameter Minimum
Stack.
Height
Inches ' Stack,
One Boiler Ft.
'Grate Dtmen-' sions. Inches
Heating Surface, Sq. Ft.
Diameter
Smoke Con nection. Inches
Space at Front
for Drawing
Tubes
Size
of Outlet
Inches
Size of
Return Inches
604 605 606 607
608 609 610
611 612 613
614 615 616.
617 618 619
620
621 622 623
624 625 626 627
628 629
850 1000 1150
1300 1450 1800 2300 2800 3300 3900 4500 5000 5500 5800 6500 7500 8300 9000
ioooo
12000 14000 15500 18000 20000
22500 25000
60
60 60 60 60
64 64
68
68 68
68 75 . 75
75 81 81 81 89
89 99 99
106 106
119
119 119
39x49
39x55 39x61 39x67
39x73 43x67 43x79 47x81
47x93 50x94
50 x 106
58x96 58 x 102
58x108 63x96 63 x 108 63x114
71 x 112 71x124 78x 113 78 x 125 86 x 129
86x141 96 x 145
96x157 96 x 169
11
11 11 11 11
13 13 15 15 17
17 17 17 17
22 22 22
24 24 23
28.
30 30
33 33 33
45
21x23
73.0
12
34 3 ^ 2
45
21 x27
87.0
12
40 3 2
45
21 x 31
100.0
12
46 3 2
45
21 x35 114.0
12
52 3 2
45
21x35 122.0
12
50
25x35 152.0
14
50
25x43 189.0
14
58
52 64
3 4 4
2avAh
55
29x43 234.0
16
64 5 3
55
29x47 279.0
16
76 5 3
60
31x47 318.0
<8
77 5 3
60
31 x 51 372.0
18
89 5 3
60
37x47 392.0
18
77 6 3
65
37x51 415.6
18
83 6 3
65
37x51 457.6
18
89 6 3
65
43x55 508.5
24
77 7 4
70
43x63 594.8
24
89 7 4
70
43x67 637.5
24
95 7 4
70
50x55 708.7
26
89 8 4
75
50x59 809.5
26
101
84
75
54x67 864.5
30
89 8 4
75
54x71 988.8
30
101
84
85
66x67 1183.8
32
101
8
5
85
66x71 1332.9
32
113
8
5
100
78x67 1500.0
36
114 10
6
too
78x71 1665.0
36
126 to
6
100
78x75 1830.0
36
138 to
6
PACIFIC DIRECT DRAFT STEAM BOILERS
Catalog Num
ber
Net Rating
Height Water
Line. Inches
Dimen sions
Overall, Inches
Diameter Stack. Inches
Minimum
Height Stack.
Ft.
Grate Dimen
sions. Inches .
Heating Surface,
Sq. Ft.
Diameter Smoke Con nection. Inches
Space at Front
for
Drawing Tubes
Size of
.Outlet Inches
Size of Return Inches
204 700 205 825 206 950 207 1075 208 1200 209 1500 210 1900 211 2350 212 2750 213 3200 214 3700
215 4100 216 4500 217 4800 218 5300 219 6200
220 6700 221 7500 222 8500 223 10000 224 11500
225 13000 226 15000 227 17000
228 19000 229 21000
60 60 60 60 60 64 64 68 68 68 68 75 75 75 81 61 81 89 89 99 99 106 106 119 119 119
39x49 39x55 39x61
39x67 39x73 43x67 43x79 47x81
47x93 50x94 50x106 58x96 58 x 102 58 x 108 63x96 63 x 108 63 x 114 71x112 71 x 124 78x113 78 x 125 86x 129
86x141 96x145 96x 157 96 x 169
11 11 11 11 11 13 13
15 15 17 17 17
17 17 22 22 22 24 24 28 . 23 30 30. 33 33 33
40
21x23
73.0
12
34 3 2
40
21 x27
87.0
12
40 3 2
40
21 *31
100.0
12
46 3 2
40
21 *35 114.0
12
52 3 2
40
21 x35 122.0
12
58 3 2
45 25x35 152.0 14 . 52 4 *A
45
25x43 189.0
14
64 4
50
29x43 234.0
16
64 5 3
50
29x47 279.0
16
76 5 3
55
31 x47 318.0
18
77 5 3
55
31 x 51 372.0
18
89 5 3
55
37x47 392.0
18
77 6 3
60
37x51 415.6
18
83 . 6
3
60 37x51 457.6 18 . 89 6 3
60
43x55 508.5
24
77 7 4
65
43x63 594.8
24
89 7 4
65
43x67 637.5
24
95 7 4
65
50x55 708.7
26
69 8 4
70
50x59 809.5
26
101
84
70
54x67 864.5
30
89 8 4
70
54x71 988.8
30
101
84
75
66x67 1183.8
32
101
85
75
66x71 1332.9
32
113
85
90
78 x 67 1500.0
36
114 10
6
90
78x71 1665.0
36
126 10
6
90
78x75 1830.0
36
138 10
6
Pacific Boilers are so constructed that all of the tubesf both upper and lower banks, can be cleaned or removed from the front of the boiler through the front flue doors.
255