Document dnkqXDL54YaVnEGr5xbr59Yze

Boilers Irvington, N. Y. Makers of Low Pressure Cast Iron Boilers Twin Section for heavy duty work. Sections and grates both being twins, con Pass through small opening. No rights and lefts to sections. Three men can set it up. Burnham Square Sectional boil ers are based on the principle that a long fire travel (correctly pro portioned) reduces fuel bills. The hot gases go back and forth three times the length of the boiler, on each side of the boiler, before they are led to the smoke box opening. Because of the individual side flue openings, each section absorbs an equal amount of heat. Burnham steam boilers have such a low water line that they can be used in shallow cellars. They are so constructed that the size of the steam dome is not sacrificed. Every operating part is handy in front of the boiler. Every flue has a separate clean out door. 254 TWIN SECTIONAL FOR HEAVY DUTY Steam Boilers Number Crate Area Sq. Ft. No. and Size of Outlets Inlet* No. and Size of Safety Valve Rating Sq.Ft. S-50-6 S-50-7 S-50-8 S-50-9 S-50-10 5-50-11 S-50-12 W-50-6 W-50-7 W-50-8 W-50-9 W-50-10 W-50-11 W-50-12 19.27 22.92 26.56 30.20 33.85 37.5 41.14 3-5" 3-5" 4-5" 4-5" 4-5" 5-5" 5-5" 3" 3Vl" 3'/i" 3VY'&2" 3i/2"c2" 3,/i" ic 3" 3%"&3" Water Boilers 19.27 22.92 26.56 30.20 33.85 37.5 41.14 4-5" 4-5" 5-5" 5-5" 5-5" 6-5" 6-5" 6,250 7.425 8,600 9,775 10,950 12,125 13,300 10,300 12,250 14,200 16,150 18,100 20,050 22,000 SQUARE SECTIONAL Steam Boilers Number Grate Area Sq. Ft. Size Supply Tap pings Size Return Tap pings Rating Sq. Ft. S-18-4 S-18-5 S-18-6 S-18-7 S-24-5 S-24-6 S-24-7 S-24-8 S-30-5 S-30-6 S-30-7 S-30-8 S-30-9 S-36-6 S-36-7 S-36-8 S-36-9 S-36-10 S-36-11 W-18-4 W-18-5 W-18-6 W-18-7 W-24-5 W-24-6 W-24-7 W-24-8 W-30-5 W-306 W-30-7 W-30-8 W-30-9 W-36-6 W-36-7 W-36-8 W-36-9 W-36-10 W-36-II 3.00 -3'/2" 3.94 2-3*A" 4.88 2-3 5.81 2-3'A" 5.17 2-4" 6.42 * 2-4" 7.67 2-4" 8.92 2-4" 6.46 2-4" 8.02- - 2-4" 9.58 2-4" 11.15 3-4" 12.71 3-4" 9.88 2M" 11.75 3-4" 13.63 3-4" 15.50 3-4" 17.38 4-4" 19.25 4-4" 1-3'/2" 2-3'/2" 2-3'A" 2-3'f2" 2-4" 2-4" 2-4" 2-4" ' 2-4" 2-4" 2-4" 2-4" 2-4" 2-4" 2-4" 2-4" 2-4" 2-4" 2-4" Water Boilers 3.00 3.94 4.88 5.81 5.17 6.42 7.67 8.92 6.46 8.02 9.58 11.15 12.71 9.86 II.75 13.63 15.50 17.38 19.25 2-3'/2" 2-3'A" 1-Wi" 2-4A 2-4" 2-4" 3-4" 2-4" 2-4" 3-4" 3-4" 4-4" 3-4" 3-4" 4-4" 4-4" 5-4" 5-4" 2-3'/2" 2-3'/2" 2-3>/2" 3-3'/2" 2-4" 2-4" 2-4" 3-4" 2-4" 2-4" 3-4" 3-4" 4-4" 3-4" 3-4" 4-4" 4-4" 5-4" 5-4" 750 950 1,150 1,350 1,350 1,700 2,050 2,400 1,750 2,250 2,750 3,250 3,750 2,850 3,500 4,150 4,700 5,350 6.000 1,250 1,575 1,900 2,225 2,225 2.800 3,375 3.950 2,900 3,715 4,530 5,345 6,160 4,700 5,775 6,850 7,925 9,000 10,075 Boilers General Boilers Company Manufacturers of Pacific Steel Heating Boilers, Pacific Circulating Tanks Waukegan, Illinois PACIFIC SMOKELESS STEAM BOILERS Catalog Num ber Net Rating Height Water Line, Inches Dimen sions Overall. Inches Diameter Minimum Stack. Height Inches ' Stack, One Boiler Ft. 'Grate Dtmen-' sions. Inches Heating Surface, Sq. Ft. Diameter Smoke Con nection. Inches Space at Front for Drawing Tubes Size of Outlet Inches Size of Return Inches 604 605 606 607 608 609 610 611 612 613 614 615 616. 617 618 619 620 621 622 623 624 625 626 627 628 629 850 1000 1150 1300 1450 1800 2300 2800 3300 3900 4500 5000 5500 5800 6500 7500 8300 9000 ioooo 12000 14000 15500 18000 20000 22500 25000 60 60 60 60 60 64 64 68 68 68 68 75 . 75 75 81 81 81 89 89 99 99 106 106 119 119 119 39x49 39x55 39x61 39x67 39x73 43x67 43x79 47x81 47x93 50x94 50 x 106 58x96 58 x 102 58x108 63x96 63 x 108 63x114 71 x 112 71x124 78x 113 78 x 125 86 x 129 86x141 96 x 145 96x157 96 x 169 11 11 11 11 11 13 13 15 15 17 17 17 17 17 22 22 22 24 24 23 28. 30 30 33 33 33 45 21x23 73.0 12 34 3 ^ 2 45 21 x27 87.0 12 40 3 2 45 21 x 31 100.0 12 46 3 2 45 21 x35 114.0 12 52 3 2 45 21x35 122.0 12 50 25x35 152.0 14 50 25x43 189.0 14 58 52 64 3 4 4 2avAh 55 29x43 234.0 16 64 5 3 55 29x47 279.0 16 76 5 3 60 31x47 318.0 <8 77 5 3 60 31 x 51 372.0 18 89 5 3 60 37x47 392.0 18 77 6 3 65 37x51 415.6 18 83 6 3 65 37x51 457.6 18 89 6 3 65 43x55 508.5 24 77 7 4 70 43x63 594.8 24 89 7 4 70 43x67 637.5 24 95 7 4 70 50x55 708.7 26 89 8 4 75 50x59 809.5 26 101 84 75 54x67 864.5 30 89 8 4 75 54x71 988.8 30 101 84 85 66x67 1183.8 32 101 8 5 85 66x71 1332.9 32 113 8 5 100 78x67 1500.0 36 114 10 6 too 78x71 1665.0 36 126 to 6 100 78x75 1830.0 36 138 to 6 PACIFIC DIRECT DRAFT STEAM BOILERS Catalog Num ber Net Rating Height Water Line. Inches Dimen sions Overall, Inches Diameter Stack. Inches Minimum Height Stack. Ft. Grate Dimen sions. Inches . Heating Surface, Sq. Ft. Diameter Smoke Con nection. Inches Space at Front for Drawing Tubes Size of .Outlet Inches Size of Return Inches 204 700 205 825 206 950 207 1075 208 1200 209 1500 210 1900 211 2350 212 2750 213 3200 214 3700 215 4100 216 4500 217 4800 218 5300 219 6200 220 6700 221 7500 222 8500 223 10000 224 11500 225 13000 226 15000 227 17000 228 19000 229 21000 60 60 60 60 60 64 64 68 68 68 68 75 75 75 81 61 81 89 89 99 99 106 106 119 119 119 39x49 39x55 39x61 39x67 39x73 43x67 43x79 47x81 47x93 50x94 50x106 58x96 58 x 102 58 x 108 63x96 63 x 108 63 x 114 71x112 71 x 124 78x113 78 x 125 86x 129 86x141 96x145 96x 157 96 x 169 11 11 11 11 11 13 13 15 15 17 17 17 17 17 22 22 22 24 24 28 . 23 30 30. 33 33 33 40 21x23 73.0 12 34 3 2 40 21 x27 87.0 12 40 3 2 40 21 *31 100.0 12 46 3 2 40 21 *35 114.0 12 52 3 2 40 21 x35 122.0 12 58 3 2 45 25x35 152.0 14 . 52 4 *A 45 25x43 189.0 14 64 4 50 29x43 234.0 16 64 5 3 50 29x47 279.0 16 76 5 3 55 31 x47 318.0 18 77 5 3 55 31 x 51 372.0 18 89 5 3 55 37x47 392.0 18 77 6 3 60 37x51 415.6 18 83 . 6 3 60 37x51 457.6 18 . 89 6 3 60 43x55 508.5 24 77 7 4 65 43x63 594.8 24 89 7 4 65 43x67 637.5 24 95 7 4 65 50x55 708.7 26 69 8 4 70 50x59 809.5 26 101 84 70 54x67 864.5 30 89 8 4 70 54x71 988.8 30 101 84 75 66x67 1183.8 32 101 85 75 66x71 1332.9 32 113 85 90 78 x 67 1500.0 36 114 10 6 90 78x71 1665.0 36 126 10 6 90 78x75 1830.0 36 138 10 6 Pacific Boilers are so constructed that all of the tubesf both upper and lower banks, can be cleaned or removed from the front of the boiler through the front flue doors. 255