Document dnB8EMzY9a4x8E86YEJ5XgpzR
INTERNAL CORRESPONDENCE
SOLVENTS & COATINGS MATERIALS DIVISION Energy Systems Department
i
y . %. ^si ' i.
V;.,.. ;,.V
* ^ .
: UC 149- 2
I - ** L"' ; ..
h\^ ' -1- :'s ' j .
P. O. BOX
D. 1
fTY, TEXAS 77590
DATE:
March 7, 1985
TO: COPY:
Mr. R. W. Klein
Mr. J. W. Beard - 511 Mr. B. V. Binford Mr. T. 0. Blum Mr. G. G. Cochran Mr. V. D. Dutcher - 803 Mr. D. C. Kirby - 511 Mr. F. C. Phinney
Mr. J. M. Poulson - 511
Mr. F. S. Provenzano Mr. G. D. Twait
Mr. D. T. Waters - 511 . Mr. H. W. Wegert - 511 - Mr. R. C. Wise Mr. R. L. Yelton - 500
SUBJECT: OS/HS No. 3 Powerhouse - Texas City Plant Update No. 3 (1st Quarter 1985)
Attached is the update on the Response/Actions to the subject survey which was conducted February, 1984.
Status of the action planned is summarized as follows:
1. Complete 2. On-Hold
21 3
Subtotal 3. Incomplete
24 3
Total
27
The 3 incomplete and 3 items on-hold are circled in the text for easy reference.
KWK/1rt Attachment
Ken Klyng^
UCC 022251
HL.l Knockout Pots - Cont'd
Response
'
The drains will be re-routed to one unit blowdown pot minimizing any
possible personnel exposure.
Completion Date: Complete
Responsibility: G. G. Cochran
HL.2 Removal of Asbestos-Containing Insulation
Asbestos-containing insulation is still present in- the Ho. 3 Powerhouse
facility. Some activities require that this insulation be stripped. When the
maintenance department insulator strips asbestos-containing insulation, OSHA
CFR 1910.1001 regulations are reported to be followed. However, employee
exposure to ambient concentrations of asbestos fibers have reportedly occurred
at times when:
.
1) Unit personnel disregard the barriers installed around the area
where asbestos-containing insulation ts being removed.
2) Maintenance personnel other than insulators unintentionally strip
asbestos-containing insulation.
3) Insulator's outer clothing which is contaminated with asbestos
fibers is not properly removed,
4) Winds carry the asbestos fibers outside the area that is barricaded
for the removal operation.
Recommendation Continue emphasizing to unit personnel the importance of obeying barriers and the importance of following established procedures when removing asbestos-containing insulation and when removing asbestos-contaminated clothing. When the insulation material is unknown, the insulation should be treated as though it contains asbestos.
Response All personnel in the area will be removed from roped off areas during removal, of asbestos insulation.
Completion Date: Complete
Responsibility: 3. Vyvial