Document dn717dbw9KkNK6z3KOzQ3ym9R
PATRICK R. ATKINS
PITTSBURGH OFFICE
DR. L. OLMTAK
SURINAME OPERATIONS
1977-06-06
RE: HEALTH IMPLICATIONS OF MOENGO KILN DISCHARGES
George Farrah examined a sample from Moengo Kiln No. 10 which was collected several years ago as part of a study to determine engineering design characteristics of pollution control equipment. Visual and chemical analyses of these particles have led Tom Bonney and Bert Dinman to the conclusion that there should not be a health hazard associated with these emissions. Therefore, the major reason for kiln control efforts at Moengo should be the nuisance factor. As I stated in my report concerning Suriname Operations, I am of the opinion that every effort should be made to reduce emissions through process control, but at this time Suriname Operations ought not to embark upon a capital intensive program to install abatement equipment
Miles Colwell has indicated to me that if emissions cannot be reduced by process control he feels that the nuisance situation should be considered carefully before a decision is made not to control those emissions by abatement equipment. You and your colleagues are in the best position to make that determination and recommend strategy.
I will be happy to continue our discussions on this subject with you at any ifmev
PRA:mh
Attachments
cc: Dr. M. 0. Colwell - 29 Dr. B. D. Dinman - 7 Mr. T. B. Bonney - 7 Mr. G. H. Farrah - ATC
468415 0061
THOMAS B. BONNEY
HEALTH & ENVIRONMENT DEPARTMENT PITTSBURGH OFFICE, 7AB
DR. P. R. ATKINS PITTSBURGH 7Afl
1977 May 13
RE: BAUXITE DUST, PARANAM
EL
Reference is made to the analytical reports of the captioned sample obtained from Paranam Kiln No. 10 stack. None of the materials detected are of any significant health concern. It is the analyst's convention to report the elements found as oxides, the most likely form in which they are present. However, in the case of silicon, reported as 4% SiOg, it is highly unlikely that crystalline silica, a potentially harmful material, is present in any significant amount. It is expected that most, if not all, of the silicon is present as a relatively harmless silicate. This is typical of most of the bauxites we mine. If crystalline silica were present in any significant concentration (e.g. greater than 0.5%), it would have been seen on the x-ray diffraction report.
On the basis of the x-ray diffraction and x-ray fluorescence analytical reports, we conclude that the most likely problem to be created by emissions from the No. 10 kiln is that of nuisance.
THOMAS B. BONNEY
y"
G ALCC
468415 0062
MATH IAI
*> 0.1. mi r.L -ri~
0
:
.-
ALCOA RESEARCH LABORATORIES
ANALYTICAL CHEMISTRY DIVISION
ASSIGNED TO Kriwr (17) nr 114) oatc suftMrrrcD 3/14/77
DATE *PO*TEO
- *fh.
i PurtUllT oalolMd bwlU
i of toacio
> 77-#llA#7
50 7MM4H
NO- SHE.
^
r
r+ru *'.
.J,r~.> <<' Of-
7-/'
/ J.
J
Jx C< k-- LX.it i1,, --t//^/ SS' */ *
;> refi?r +
-c Lz *-t <\dC
Kt'JtS .
X l?i) at 7-*$^$/,i',&M'r--
- V
V
T ^/-XS.-iO--3.-.---- 4, Ob
r -
Fe,0,
4.35-
TK), ` .v
Al,0.
1? 86-0
t CaO
.0A
MnO Cr,0,
.o/
./JL
P,C, ,/y
ZrtX /4
SO, .32.
CuO o3
ZnO .02-
Ga,0, MgO
.o
LOF 5-.b
^ J / s. *
ai & ,7 -
3` v-V
* * L-^
f*VJ 41* g
<
-- V*
' :
*
. r/A *vy*>-
- **
... -
- \?vi .
*
iAB REF <533; 77
i-
*0M . M
^ A.
ANAliffDBY
/t'^y * A- i? </// 77
TEST SHE^T
Aff*OVfO>*
tsj-n 468415 0064
ALCOA RESEARCH LABORATORIES
ANALYTICAL CHEMISTRY DIVISION
mathiAt Kaoxit*
assigned to xxammr (17) HP (14)
OWCE KMT.
date submitted 3/14/77
KT TO
ParrMil
DATE REPORTED
oc< P.I. Atkina - Fgh.
J O 77-031407
so 7fA50494
NO. SPIE.
|
Submittedi Partially oalcined bauxite
Determinei
XU> and XRP for presence of toxia elements, oompounda, crystalline forms
received
APR 1 8 1977
SL flO
PATRICK R. ATKINS
./-r/A
/7f\_
-- c a ur 7J U/11 .
3
7"/ C
A Vf, T Aii )
* H
tti1 c
"1 -~ n, 7V // r>r/ r/ tb )
i /( 1 AJ D/ n rtf
1A A -- r-
Z' V) s/vo &e__ 7| '<e/t c^r / 1/A/OA
yist
^ -T _-{*C'
a'lr/t t v.. -
7
-
^ C'
.
- * f-# '*. .>'*'
-.
'; > *
1*8 K ^
*<Mf , ml
j 1ANAI ED Bv /C
TEST SMEET
'
468415 0065
r.iiuRc.r: h. r-.RKAii ENVIRONMENTAL HEALTH LAP/lR \T 'KV ALCOA I ELIIN i C\l. CENTER - C
DR. P. R. AIK! NS
PTTTSl'tRC-H OFFICE - 7
:ref ,Tn
April 14, 1977
/ : A : R*T: "
RE: BAL'XTFE Ul'ST, PAKANAM - I.ILNo. 2833
A specimen oi bauxite dust, collected at I'aranam Kiln No. 10 stack and submitted by Mr. B. 1. Grant lor determination of particle size distribu tion, has been reexamined by scanning electron microscopy as you requested. Attached are the photom iciographs taken at 50X, 200X, and 500X by AL-Phvsical Metallurgy Division.
.;A, ' -- L
GEORGE H. FARRAH
GHF:ds
Attachments (!)
ALlGA
468415 0066
` GEORGE H. KARRAH ENVIRONMENTAL HEALTH LABORATORY ALCOA TECHNICAL CENTER - C
CORRECTED REPORT
DR. P. R. ATKINS
PITTSBURGH OFFICE - 7 R"C-JY
JUN I b i /
1977-05-31
PATRICK R ATKINS
RE: BAUXITE DUST, SURINAME
The sample of bauxite dust reported 1977 April 14 under the caption "Bauxite Dust, Paranam - I.H. No. 2833" was incorrectly identified. The specimen is correctly identified as Bauxite Dust, Moengo - I.H. No. 2635.
GEORGE 'H. FARRAH GHF:ds
f L
:oa
46B415 006?
Alcoa
Sooey-Slats
for swine farrowing, nursing and finishing
lVdv
6. t n `
bo c/.
"
t I -i
'j oo <i -- i v ~f , ~f~
\Sl.C -j
468415 0068
THOMAS B. BONNEY
HEALTH & ENVIRONMENT DEPARTMENT PITTSBURGH OFFICE, 7AB
DR. P. R. ATKINS
PITTSBURGH 7AB
RECEIVED
1977 May 13
* 6 1977
PATRICK R. ATKINS
RE: BAUXITE DUST, PARANAM
Reference is made to the analytical reports of the captioned sample obtained from Paranam Kiln No. 10 stack. None of the materials detected are of any significant health concern. It is the analyst's convention to report the elements found as
oxides, the most likely form in which they are present. However, in the case of silicon, reported as 4% Si02, it is highly unlikely that crystalline silica, a potentially harmful material, is
present in any significant amount. It is expected that most, if not all, of the silica., is present as a relatively harmless silicate. This is typical of most of the bauxites we mine. If crystalline silica were present in any significant concentration (e.g. greater than 0.5%), it would have been seen on the x-ray diffraction report.
On the basis of the x-ray diffraction and x-ray fluorescence analytical reports, we conclude that the most likely problem to be created by emissions from the No. 10 kiln is that of nuisance.
THOMAS B. BONNEY TBB:lmn
#
ALCOA
468415 0069