Document dn4kMG4QJGE1Yj2oKLVoV8R7B
E. I. DU PONqjDE NEMOURS 51 COMPANY
CMaiNCCRINO OCPAftTMCNT
PERSONAL AND CONFIDENTIAL T: K. E. KEUPER
LOUVIERS BLDG. ROOM 1285
In reply pl*are ust tubjtd |Ut*d blew.
Date: December 14, 1966 c*-* R.E. Mason-Wilm.
~ CONSTRUCTION - BEAUMONT
Subject: APPLICATION OF LIMPET INSULATION
As you might know, BeauaoaC Construction was the first site to use Limpet insulation. He, therefore, are quite concerned about the . results of the testing program at Chambers Hocks Construction.
Realizing that Limpet is by no means the only source of asbestos dust, ve are adhering to the following practices:
1. Limpet spraying is being performed in an isolated
area away from shops and locations where the dust might be pulled into air conditioning systems, etc.
2. The insulators engaged In Limpec spraying are required
to wear fresh air supplied respiratory protection.
We have also ordered the MSA cartridge type respirator
and ultra-high filter type H, micron density
cartridges.
**
3. Shop men and craftsmen are required to wear respirators while cutting materials containing asbestos indoors. This applies to handsaw as well as power driven saw operations.
4. A vacuum cleaner has been ordered for shop cleaning. The insulation shop will be kept clean and free of accumulations of dust.
He have not discussed the possibility of having insulators X-rayed and will nor consider doing so unless advised co the contrary.
Please be advised that any action taken lately at this site regarding the safe handling of Limpet has been done discreetly and quietly with the craft superintendent.
tjV3
JCJ:ee
DUP 0900765 SC-DP-01655