Document dn0eQY6b6NVaK5qrDBr9D5v7R

HOMS 0 76556 .' i* * CNS 07855 7 Dj MONSANTO NOOSE 1-1 S VIOTONIA STNEET LONDON SW1 HONS 078550 APPENDIX I Compatibility Twtlaf Method as 33 MCNS 078559 The Aroolor* dielectrics are a range of chlorinated diphenyls pro duced by Monsanto for the manufacture of Impregnated paper capaoltore. These products are generically known as 'askarels', that Is, synthetic fire resistant Insulating liquids which. If deconipoesd by an eleotrlo arc, evolve only non-explosive gaseous mixtures. The Aroolor liquids woro first used In tho United Btatos In 1001 and to-day they are extensively used In the capacitor industry through out tho world. Monsanto has been producing Aroclor at Its Newport plant since 1961. There are three grades of Aroclor, Identified by their code numbers: Aroclor 1242 (Commercially known as Trlchlorodlphenyl) the most economically attractive, is essentia) for outdoor capacitors In a low temperature environment, but Is the most difficult to handle in produotlon. Aroclor 124$ (Commercially known as Tetrachlorodlphsnyl) Is a compromise between the economic advantages of 1212 and the ease of handling of 1264. Aroclor 1254 (Commercially known as Fentachlorodlphenyii is the eaalest to handle lo production and Is sometimes ohosen for capaoltore to operate In exceptionally hot environments, but does not gain the maximum economic advantage. Advantage* Ulng Areeler Reduced else capacitors are possible for a given rating; fluorescent lighting unite are a particular application In which this Is utilised. Reduced raw material cobI arising from the smaller quantity of paper and foil needed In manufacture. * Aroolor Is a Registered Trade Mark. WCas 078560 3 Reduced labour content because of the fewer windings required. Increased through-put from a given plant oapaclty with existing labour foroo. Higher stress operation of cap&oltors Is possible because of a more uniform permittivity In the capacitor. Longer life capacitors are produoed becaueo of tho high stability and resistance to oxidation of Aroclor. Small Are hazard because Aroclor Is flre-realnUnt. 4 MGNS 078561 dMd. Values for the most Important properties of the Aroclor dielectrics are given In the Table. Typical properties of the Arcelor dielectrics (The# valvet do nrt renalUut* a Property Relative Denetty at ao/atrc Pour Point (*C) VUotttty at SD*C (cB> CoRfflolml of upanaloD *0 Cpeollto heat al76 C (J/g *C) Thsrma) oonducUvIly at 76'C (W(m '0) Evaporation loan (%) (S h at 130*0 Plaah Point (*C) ASTM DS3/S3 Fire Point ltotracvivo Index Inortnnle chloride* (ppm) Acid number (m*KOH/t) Water content (ppm) Permittivity at 20*C and SO o/e PwiMitUvIly at 100C and BO ofa Lose tensant at 100*C and SO ora D C realaUvIty at HXTC and SOD V/mm attar 1 min. eleotrlfloatton (TO om) Dielectric etrenrUi at 90'C (kV) (B.B. 140:1900) 013 1M (min) None 1 OH 0.1 (max) OOl (max) 96 (max) 0 1 (max) 001 (max) A (max) 3M(mln) None I no Composition Aroclor le made by the chlorination of diphenyl to predetermined chlorine contents which are Indicated as a percentage by the last two digits In the code number e.g. Aroclor 1249 contains 40% chlorine by weight. Bach Aroclor contains a range of chlorudlphenyls with differing numbers of hydrogen atoms substituted by chlorino, and In each of these chtorodlphenyls there Is abundant Isomerism. PtiyslMl proportiss Viscosity The viscosity-temperature characteristics of the Aroclor liquids are shown in Figure 1. It can be seen that Aroclor 1254 is the most viscous at alt temperatures and Aroclor 1242 the least. The differences between the three grades are greatest at lower tompora- HONS 078562 S ture and become leu as the temperature is raised. As previously explained, Aroolor oonetets of a number of homologuee and oooeequently eaoh grade does not have a sharply defined melting potot. but remains liquid over a wide temperature range. Instead, their viscosities Increase smoothly but sharply as the temperature is reduced. Aroclor 1242 has the lowest pour point of all three grades. Vapour Pressure It can be seen that Aroclor 1242 has the greatest vapour pressure at a given temperature and Aroclor 1254 the least, and this needs to be considered when deciding the temperature of Aroclor during degaslfloation and Impregnation. The vapour preesure of Aroclor varies with absolute temporature according to the usual logarithmic law. The variation of the vapour pressures of the Aroclor dielectrics with temperature is shown In Figure 2- fihemlosf prspertisl The ohemloal Inertness of Aroclor Is outstanding. The liquids are not oxidlsod by exposure to air or oxygon even under extreme condi tions of temperature and pressure, nor do thoy react with moisture. When subjeoted to a bomb test at 140"C In oxygen at a pressure of 360 p.s.I.g. (1? kg/cm'), there was no evidence of oxidation ae Judged by development of aoldlty or formation of sludge. They oan withstand many years of servloe tn electrical equipment at high temperatures without oxidation. Aroclor Is manufactured to a rigid specification ensuring a low Initial value for free acidity and free chlorides. Tests have shown that these low values are maintained even when the liquids are heated for prolonged periods In the presence of air and moisture at temperatures of 100*C. Aroolor 1242 Is slightly sensitive to ultra-violet light, whloh oan result Id the formation of traces of ionic contaminants. The other grades are relatively unaffected by exposure to light. Aroclor undergoes no decomposition at temperatures up to 176'C. At much higher temperatures, or when subjected to arcs, the prin cipal decomposition products are carbon and hydrogen chloride. Laboratory tests and practical experience fame shown that phosgene, chlorine, or hydrocarbons are not formed as decomposition products of Aroclor. Electrical prcpcrtlcs The laboratory methods used to measure the electrical properties of the Aroolor dielectrlos are described tn Appendix A. Permittivity (Dielectric 'constont') The permittivity of Aroclor is high er than that of mineral oil, which accounts for iho size reduction MCNS 078563 and increase in stress that is possible. Stresses of 16 to 17 V/jiin are common with Aroolor and higher values are reported. Sinoe chlorinated diphenyls are polar compounds, their permiUivitis are highly temperature-dependent. This Is illustrated in the upper part of Figure 4, which shows the variation with temperature of the permittivity of each of the three grados of Aroolor. These reading* were taken at a frequency of 50 c/s and an electric stress of 1 V/(im. At the lowest temperatures, all three grades have a permittivity of about 28, since, beoauee of the very high viscosity, thsrs Is no con tribution from dipole orientation polarlsabJUty. Ae the temperature is Increased, the permittivity begins to inoreaso when the viscosity becomes sufficiently reduced to allow the molecular dipoles to orientate themselves in the alternating electric field. The tempera ture at whloh this Increase In permittivity begins Is dependent upon both the grade of Aroolor, being lowest for Aroclor 1242, and the frequency of the applied field. Ae the temperature Is further Increased, the permittivity passes through a maximum, and then decreases. This decreaso in permit tivity with Inorease of temperature Is due mainly to the dleturbanoe of the alignment of the dipolos by thermal agitation. The maximum permlttlvitlee attained vary with the grade of Aroclor, being great est for Aroclor 1242 and least for Aroclor 1254. With Aroclor 1342 the permittivity of this series reaches a maximum, and a further reduc tion In ohlorine content causes a reduction in permittivity, ae shown In Figure 3. Although the permittivity ofAroclor 1342 is of a high order.continued research on these produots has revealod tho possibility of obtaining even higher permittivities with this class of material. It Is Ilkoly therefore, that the final word hae not been written on this subject and that improved produots will become available In this field In the course of the next few years. Loss Tangent The lose tangent, or power factor, of Aroclor le also highly temperature dnpondent. This 1s illustrated In the lower part of Figure 4. which shows how tho loss tangents plotted here on a logarithmic scale of each of tho three grades of Aroclor vary with temperature. The curve for each grade of Aroclor consists of apeak due to absorp tion associated with the transition in permittivity, followed by a region where the lose tangent steadily increases with temperature. In this latter region, the lose tangent follows the Increase in fluidity with increasing temperature and is highly dependent upon the purity of the Aroclor. The temperature at whloh the peak occurs is about 19" below the pour point. MGNS C78564 Tbs loss tangent of Aroolor 1b greater than that of fresh mineral oil, but by selection of a paper of lower density the lose tangent of the Impregnated oapad tor oan be minimised without saorinctnc the eoonomto advantages. Furthermore, the Internal temperature dees not rise beyond acceptable values. t>.c. Resistivity The values quoted In the table are typical for Aroolor aa produced, but they can be Improved by vacuum dehydration and values of 20 to 60 T ft om at 100'C are ootnmou. The values for Aroclor 1242 and 1246 are lower than 12M because a given amount of contamination reduces the d.c. resistivity more with a liquid of lower viscosity and higher permittivity. The variation of the d.o. resistivity of the 3 grades of Aroclor with temperature Is shown in Figure 6. HONS 078565 4* ,"'4 f tiNnitimico Flgara 1 Tha vtaeNitf-tamparatora ebaraetarlatloa af tla Aradar tflalaotrtaa MONS 078566 Figaro t Tha variatlaa of the *M#nr prmin ef the Areolar 41electrics with teaiparatora 10 MGNS 07856V I m If i * --l- 1 ^J I |i 1' ! 1 _ _ _ _ _ _ L_ _ _ /_ _ // / 1jj // J | ! 'T 1 ; i _ _ _ _ _ _ |_ _ _ _ _ _ !_ _ _ _ _ _ |_ _ _ _ _ _ i _ _ I I 1 5 j 1 1 J i HONS 07856S MGNS 078570 FM4 nwHiwin--wiiBiUFMtfciwMini VOlVNt tltlS T IT IT I ( T A | Hfara I Tha varlatlan at tha DO railstlvRjr af tha Aradar dalaotrloa with tamparatara 14 07b5? 1 mcns Flfan Ik* if papir lnpra|uli< with Artolar M)KS 078572 16 FlgartT Tki Kimuli Ailietrie Int 01H 16 MCNS 078573 CONSTRUCTION OF AROOIOR CAPACITORS Pptr Kraft paper is strongly recommended slnoe it has nearly 6 times the sold neutralising properties of rag tissue. The permittivity of Impregnated paper depends upon the density of the paper as well as the permittivity of the impregnant. This rela tionship Is shown In Pigur* 6 for the 3 grades of Aroclor and for mineral oil, the values being calculated at a temperature of 20'c. Slnoe paper impregnated with Aroclor 1342 has the highest per mittivity, the leaet area of windings Is nooded to obtain a given value of capacitance and the greatest economy is obtained. It is advantageous to use low density paper since It has been shown both theoretically and practloally that such paper gives the least dlelectrlo loss in a oapaoltor. This street arises from the distribution of electrical stress between the cellulose fibres and the Impregnant and Is In addition to, and Independent or, an; losses in the impreg nant Itself. Most manufacturers of oapaoltor tissue are familiar with Aroclor and have developed suitable grades for use with It. Assembly ef oapaeltSf* cannot bo emphasised too strongly that every material that comes Into oontact with Aroclor must be carefully checked for compati bility. Aroclor la a good solvent fur many thermoplastics and elastomers and the resulting solution has a high dielectric loss tangent. Materials which must be considered Inolude the major Insulation, the lead-through Insulators, any means of sealing the oontatner and the residues from the manufacturing process e.g. fluxes left after soldertng. The windings should be sealed with a suitable adhesive such as gum arable or Gloy. Connection tags if of copper should be tinned, other wise stainless steel can be used. 8olderlng should bo kept to a minimum and where possible the special cored solders whloh have boon dovolopod by mnnufaoturore for ueo with Aroolor should bo employed. Opaque bushings must be used because of the slight light seneltlvity of some grades of Aroclor. particularly Aroclor 1242. MGNS 078574 17 Although the production of Aroclor Impregnated capacitors la generally similar to that of oil Impregnated unite, and similar plant may be need, there are several differences In detail and these are described In the following seotlons. If an oil plant te to be ohanged to Aroclor, no epeclat cleaning la necessary, although It Is advisable to rinse the plant firat with Aroolor which la subsequently discarded. It must be noted at this point and always borne in mind that Aroolor has a very considerable detergent effbot. That Is to say that since the density Is nearly twioe that of oil, any dirt existing in the system will be washed out due to the greater doneity offoot of the Aroolor. Earth traatmaat The main difference between Aroclor and oil oapacltor Impregnation plant le the earth treatment sootion. Aroclor, as received in drums, Is suitable for filling into capacitors after vacuum treatment but It le generally advisable to have an earth treating facility available to treat any Aroclor which oould become contaminated during the process cycJo. For example If capaoJtors are flllod by a flooding technique, then Aroclor which Is unused and which Is returned to the system will be found to bo slightly contaminated and earth treatment le advised. For this to be fully appreolaled. It must be realised that the Aroclor liquids are more susceptible to contamina tion than their mineral oil counterpart. Because of their higher solvent action and higher porinlttlvlty, the contamination level which would be aooeptable In mineral oil and which Is commonly encountered In an Impregnation plant win bo unacceptable for Aroclor. The earth treatment can be carried out In two principal ways. In the first place the earth Is contained In a oolumn and the liquid le oiroulated until the contamination Is removed. Alternatively, activated earth Is added to the liquid In a container and It Is stirred to ensure intimate mixing and then the earth Is filtered through a normal paper filler. In both cases either Fullers' Barth or activated alumina may be used and each must bo thoroughly dried. It has been found by experience in laboratory tests that the earth may bo pacified by heating to excessive tomperaturoe. and the optimum treatmont le about 160O for 6 hours. The activated 18 MtNS 078575 * , | j dtauft' v. material Is then added to tbe Aroclor to be treated at a level of ./. - /. by weight. The ueo of freshly activated earth gives a con trolled high quality of materia] from the treatment stage. However, chore still exists the problem of separating the earth and here the column technique has a considerable advantage, since circulation through the column does not necessitate further filtration. This method has the disadvantage that the oolumn gradually beoomes less active during its life and there Is not always the same degree of oonlro] ovor the treatment prooeee. Imprsgsatlea It Is oustomary to store the capacitor liquid In a large tank the else of whloh depends on whether the material la delivered In drumn or tankers. It Is strongly recommended that these storage tanks bo lagged and heated slnoe at low temperatures difficulty would be encountered In pumping the Aroclor 12M and in oertaln extremes of temperature even Aroolor 1212 can become unpumpable. After transfer from the storage tank the liquid Is first earth treated and mixod with any unused liquid drawn back from the capacitor Impregnation tank. If applicable. The treated liquid le then sub> looted to vacuum drying and de-gassing in exactly the same way as with mineral oil and after this prooess it is passed to the final storage vessel where It is held before being passed to the impregna tion seotlon. Aroolor oapaoltors may be vacuum Impregnated by a manifold technique In whloh the liquid Is piped Individually to each capacitor can and this Is perhaps more suitable for the larger power factor correction oapaoltors. Alternatively, they may be filled by a flooding technique whloh is more applicable to the smaller fluores cent lighting capacitors. Here the oapaoltors can be loaded In wire cages and completely immersed In the liquid in the same way as with mineral oil. For the actual Impregnation cycle the following temperatures are recommended; Aroolor 1242 70- 80'C Aroolor 1246/12M 90-lttTC The lower impregnation temperatures are recommended for Aroc)or 1942 slnoe as this prooess Is carried out under vacuum the losses will be greater with a liquid which Is more volatile. After the impregnation cycle has been completed tbe veseel should be oooled to below 60*C before being opened and this is to avoid the unpleasant fumes of Aroclor esoaping Into the work-shop. The oapaoltors should then be sealed ss quickly as possible and degreased before final painting and testing. Toxlolty precautions and the handling of Aroclor is dealt with In a separate section but workers handling the liquid, or capacitors coated with it, are advised to wear rubber gloves or use barrier oream, HONS C785V6 19 PERFORMANCE OF ARQQLQR CAPAOITORt A.O- OSpsefter* at If a oapaoitor la continuously onorgrieod before and whilst subjected law ambient tamparatirM to a low temperature environment It operate* satisfactorily because the heat produced in the dielectric balances the heat lost from the case. A self-compensating prooess exists such that If the tempera ture of the dlelectrlo falls the losses Increase, end more beet le generated to establish a now equilibrium. Tests heve shown that a capacitor Impregnated with Aroclor 1254 oan operate continuously energised in ambient temperatures down to -00'C, end It wee found that such capacitors satisfactorily survived whilst Installed out doors during the winter 1983-3. If, however, a capacitor Is subjected to a low temperature environ ment first and then energised It may be damaged by dischargee ooourrlng in voids formed by the oontrectlon of the dlelectrlo before It hes time to heat up sufficiently. Cases when this might occur are in street lighting oapacltors during winter, or oapacltors Installed in a plant that has been shut down during winter holiday periods. For this reason, the following minimum ambient temperature* are suggested for the 9 grades: Aroclor 1284 - 7*0 Aroclor 1248 -28'C Aroclor 1342 -46'C For operation at still lower temperatures a blend of Aroclor 12M and trichlorobeosene has been used. D.6. ospaoltirs Aroolor le also used In d.c. oapacltors but It has been round that at the high stresses used the service life of the capacitor tends to be reduoed If the working temperature le raised above 40*C. This can be overoome by using stabilisers in the Aroclor to overcome the slight electrochemical degradation whloh tends to take place. Qenerally the effect Is proportional to the quantity of slabUteor used and up to 1 per oent of enthraqulnone, or 1,0 dlchloroanthraqulnonr, and 2 per oent of esoheneene have been used. 20 HONS 078577 TOXICITY AND HANDUN8 DNCCAUIIORf Aroclor mads by Monsanto has beon nssd for over 33 years without causing any toxic effects, but It must be bandied with care. These precautions should be observed: 1 Avoid skin oontaot. Protect the hands, preferably by oil-realRtant gloves. 2 If sktn oontaot should occur, wash off with soap and water. 5 If hot Aroclor must be handled in a closed or oonflned area provide exhaust ventilation or wear an approved respirator. 4 If Aroclor gets in tho eyes, flush with large amount# of water. In the event that Irritation persists refer the patient to a Physician. 6 Infrequent exposure to Aroclor vapour will not cause any 111 effect, but prolonged exposure to a high vapour concentration should be avoided. If these precautions are neglected acne may develop and excessive exposure may cauee liver damage. HONS 078578 LABORATORY MEASUREMENT! lOOlOR TAtMtmaiiU There are many test calls available for measuring tbs electric tielsotrlo test osH properties of liquid dielectrics, but since most of these were de signed for use with mineral oil, Monsanto has designed a test cell especially for use with Aroclor. This design of cell Is uaod in our laboratories and Is available for sale to customers It Is essentially a three terminal oell with cylindrical stainless steel electrodes separated by a 1 mm gap. Figure *1 shows details of the construction of this oell. Tbs preosdsrs fer Great care must be taken to ensure careful cleaning for Aroclor feanlng and RUIng Ike cell measurements with this or any other oell. The Monsanto colt is designed for easy cleaning and accurate assembly. The Monsanto oell is first cleaned by a series of thorough washings as follows: 1 A wash with bensene 2 A thorough washing with detergent and hot tap water 3 Repeated rinsing with hot tap water 4 6 rinses in distilled water 6 2 rinses In analytical grade acetone During the wash with the powder detergent a soft hair brush is used and all parts of the electrodes are thoroughly brushed. The oell it then dried In an air oven at lVC for 30 minutos. Finally it is rinsed twice with the Aroclor to be measured before filling a third time, when the electrical measurements are taken. MssssrimenU The temperature at which the electrical properties are made is measured by a thermometer resting In the central well of the cell. For routine testa a temperature of 100' C Is used, Permittivity and loss tangont are moasured first with a transformer bridge at a stress of I V/|im and at mains frequency of 60 c/s. D.C. resistivity Is then measured with sn electronic megohmolor one minute after tbe application of a stress of 0 6 V/pm. If reposted readings of d.c. resistivity are performed on the same quantity of Aroclor In the oell, a gradual increase Is noted. It Is therefore recommended that if a repost measurement of reelsllvliy Is re quired, the cell be emptied, thoroughly cleaned, and then refilled. 22 SONS 078579 freossi OMtr*l miMsrsmsxte For operating an Impregnation plant, It la convenient to be able to measure the eleotrical properties of tba Aroolor wlthont tha neoea* slty of t*klD( samples, and a oall oan be Incorporated In the system e.g. In a flow Uns. It should be arranged that there la a turbulent flow of Aroolor through the gap between the electrodes except when a measurement Is being taken so that adequate cleaning of the electrode surfaces occurs. To obtain the same sales of d o. reals* tlvlty with a plant oell and with a laboratory oel) It la necessary for the Aroolor to be (1) stationary whilst the measurement le made, (2) subjected to tha electric field for one minute, and O) at the same temperature. OOMMTWUTY TUTfNI METROO PraesAnra if tha malarial la available In a laminar form or la a surfaoe ooatlng. a plaos 36 mm square Is oat from a sheet. Other materials are selected so that the sample taken le present at the same concentration as In the finished article. The sample le put into a glass Jar that has previously been cleaned and dried In the foltowtng sequence: 1 Wash In bensene 2 Wash with hot water and detergent 9 Six rinses with dletllled water 4 Rinse twlos with analytical grade acetone 9 Dry In an oven at 130C for 1 hour To this Jar, and to a similar one without a specimen within It, are added 60 ml of Aroolor. The Jars are then closed with ground glass lids and aged in an oven at 100*0 for 7 days. After ageing, the Jars are removed from tbs ovsn and tha sleotiical properties of the Aroolor In both the specimen Jar and the control Jar are measured at 100*0 according to the method described in Appendix A. The specimens are examined for swelling or other signs of deterioration, and any colour change of the Aroclor le noted. fMlrite The Aroolor In which tha sample has been Immersed must net eiperlenoe a decrease In resistivity below 10 terohm am. Information on materials which havo been tested Is available on request. SONS 078580 TtOtofMl ftmlM The t#pbmc*i service at*>T of Monsanto la always ready to provide additional Informa tion on th use of tho materlale indtoated In tbie report, and to aaalat manufacturers la the solution of particular problems eoeutof from their application. front coper lllutlToiien by courtesy oj Industrie Condeneatorl Applloasionl Elettroslsttronlobe Milano Every effort has been made to ensure that the Information In thla publication le reliable, but ae the conditions under which it may be applied are beyond our control, we cannot accept reaponetbillty for any results of Its use. PuMMwd by MenMato'c&wMeal* Limited rrtawd In CnaianS Vjr Oiler Prma Ltd.. Netusftarn ncnmoAL umtvtca bullbtin om Itorrinted Mnrob IMS TUa MUUoa wnnile " rravtem edition* HONS 0 7 8 5 8 1 078582