Document dmjqmvjj5660v1Qnyk9DDRjG
702
CHAPTER 36
1949 Guide
MODIFICATIONS OF REMOTE UNITS
Features, of various modifications of remote air conditioners are given in the following paragraphs.
Spray Type Unit
Fig. 4 shows a spray type unit used by designers who prefer air washing and coil wetting features. These units are equipped with a pump that sprays water or brine over the coils. Due to the direct mixing of the condensate and the spray, provision must be made for overflow in summer and replacement of water evaporated in winter.
; Dehumidifying Units
In a further modification of spray type units, absorbent brine solutions such as lithium chloride are used to remove moisture-from the air. As explained in Chapter 38, the latent heat of the moisture removed is changed to sensible heat, so that coils must be used as after-coolers to obtain the right dry-bulb temperatures. Factory produced units are also available for use with solid adsorbents such as silica gel.
Remote Room Units
For individual rooms, with cooling load requirements of J to 1| tons, remote units are available in attractive casings for installation within the room: A suspended type is shown in Fig. 3 and a floor type, such as is usually installed in place of an existing radiator, is shown in , Fig. 5. Furnished with chilled water from a central plant, these units offer a satisfactory method of conditioning existing offices, hotel, and apartment rooms. These units may be obtained with filters and outside air con nections, but for most satisfactory application are used as supplements to central systems that supply properly conditioned and filtered air to:the areas served.
Induction, type units, using primary conditioned air under pressure to induce local circulation, are. described in Chapter 43.
Self-Contained Units
' A typical large self-contained unit is shown in Fig: 6. It' is essentially
a remote vertical type conditioner mounted on top of a sound insulated
enclosure containing the condensing unit'. Air distribution is obtained by
means'of grilles mounted in the discharge plenum when the unit is located
in the conditioned area. Duct distribution of conditioned air can be
obtained by removing the plenum connecting directly to the blower dis
charge, and safing the top of the unit. '
The heat generated by the compression of refrigerant gases and that
given off by the electric motor is removed from the compressor compart
ment in four ways: by the use of a water coil in the compressor compart
ment ; by utilizing the cold suction gases; by drawing part of the return air
through the compressor compartment, and finally by circulating room air'
through the compressor compartment by means of a fan attached to the
motor shaft.
'
The. 7^, 10, and 15 ton self-contained units usually have, horizontal
type conditioners. The condensing unit enclosures are'not completely sound insulated, since they are not usually installed in the conditioned
area. Most units can be divided into two or three sections for ease of
Unit Air: Conditioners, Unit Air Coolers
703
handling and installation., Although most large self-contained units have water-cooled condensers, the 7, 10, and 15 ton units, can be obtained.for operation with evaporative condensers.
Self-Contained Room Cooling Units
Small self-contained units can be obtained with water-cooled conden sers but they are generally air cooled.
The air-cooled types are small in capacity, ranging from to 1 hp. Their principal application is for conditioning such spaces as hotel rooms, offices and residential living quarters. A duct connection between the unit and an outside window or ventilated air shaft is required to permit
\ ~7
Fig. 6. Self-Contained Water-Cooled Air Conditioner
disposal of the_ heat extracted from the conditioned area. The unit may
stand in front .of the window, or be mounted on the window sill. Various
styles and types, of windows are encountered which increase the difficulty
of making the window connections. The evaporation of condensate on
the condenser coils, as a means of disposing of this moisture, tends to
increase the condensing capacity and reduce the operating head pressure.
Some units , add supplementary water so that increased capacity , may be
obtained from constantly wetted condenser coil surface. , Connections to
an electrical outlet may be by means of a conventional cord and plug or a'
permanent electrical connection, depending on -local code rulings per
taining to the installation of small motors. The exterior finish of the unit
in metal, wood or fabric is decorated to harmonize with office or bedroom
furnishings.
`
A unit of the air-cooled condenser type for floor-mounting is shown in Fig. 7. Of the;two fans shown, the lower one acts as condenser air'fan, and in some units this fan is arranged with slingers for discharging con densate' on-the~ condenser coil while the upper fan discharges'air into the conditioned area. A feature of the design shown in Fig. 7 is that the