Document dmRGr8pEyqO9MBpjKDzRMN7R

Ethanolamines/GIycol Ethers Tier 3 Procedure Section Number: Issue Number: Original Date: Revision Date: Title: References: 24 1.0 06-08-95 06-08-95 Honeywell Nest Smart Tool Operation & Instrument Program PM Series Startup EB Mode Startup 24. Honeywell Nest Smart Tool Operation & Utility Program 1.0 Objective: 1.1 To operate the Honeywell Nest Smart Tool properly. 2.0 Responsibility: 2.1 It is the responsibility of the operations supervisor and the senior operations specialist to ensure that this procedure is fully complied with. 2.2 It is the responsibility of the senior operations specialist, the operations specialist and the instrument technician to ensure that this procedure is executed in a safe and efficient manner. 3.0 Safety Notations: 3.1 Improper use of the instrument could cause a plant trip. 4.0 Honeywell Nest Smart Tool Operation Procedure: 4.1 The following is an example of the use of the tool. FT-1287PM T-130 overheads Nest position 4,1,3,2 Max flow is 15102 with a linear signal Honeywell smart cell 0-100 Meter constant 15102 Print date: 4/19/98 Page 1 of 3 Paper Copies Of This Document Are Uncontrolled & Not Subject To UpDate. The Controlled Document Resides in File: Honeywel.doc DO A 059012 CONFIDENTIAL 4.2 _______ Proceed with the following to check and/or change the spans. T-130 overheads (FT-1287) nest position = 4,1,3,2 4.2.1 _______Hook the black lead from the instrument to the white (-) wire going to FT-1287. 4.2.2 _______ Attach the red lead from the instrument to the black (+) wire going to FT-1287. Turn machine on. 4.2.3 _______Press ID. FT-1287PM should be displayed on the screen, if it is not displayed re-renter the correct tag number. 4.2.4 _______Press URV. This should read 100. If it does not, enter the correct number. Then press enter, shift, and enter. 4.2.5 _______The screen should display "Date Nonvol" 4.2.6 _______Go back to part 4.5 and recheck. 4.2.7 _______When finished, turn machine off and disconnect wires. 5.0 PDP-11 Instrument Utility Program 5.1 Type the following from a PDP-11 terminal: 5.2 UTL MF 5.3 CHG 5.4 MF 1287PM 5.5 DIS 5.6 Check the constant. It should be 15,102. If it is incorrect, type "CON" by the prompt "change what". 5.7 Enter the correct constant. 5.8 After you have finished, type "DIS" to recheck the constant 5.9 Type "BCK" by the prompt "Change What". 5.10 Type "EX" to exit the program. Print date: 4/19/98 Page 2 of 3 Paper Copies Of This Document Are Uncontrolled & Not Subject To UpDate. The Controlled Document Resides in File: Honeywel.doc DO A 059013 CONFIDENTIAL