Responses to Field Audit Comments for Multi-City Study
The attachment to this letter provides the responsesto specific commentsraised in the field audit conducted in Columbus, GA by Mr. Jess Eldridge on July 26 and 27,1999. Each comment is listed there with the response.
Please feel free to call me at (614) 424-4964 or Rosanna Buhl, the project QA Officer, at (781) 952-5309 with further questions or comments.
Sincerely,
A
Marcia G. Nishioka
Senior Research Scientist
Atmospheric Science and
Applied Technology
MGN/RLB:llg
Attachment
Rosanna L. Buhl
Project QA Officer
d
BACK TO MAIN
RESPONSES TO MULTI-CITY STUDY FIELD AUDIT COMMENTS
Comment l a (Air Sampling):Method TO-13 "Determination of Benzopyrene and Other Polynuclear Aromatic Hydrocarbons (PAH) in Ambient air Using GC/HPLC" was cited in the QAPP as the method followed to perform the ambient air sampling. It may be more accurate to state that a modified Method TO-13 was followed in that the compounds of interest for this study are FCs and not PAHs. The analytical portion of TO-13 is detailed and the techniques used to analyze the particulate and PUF filters should be audited. An audit should also include a review of cleaning procedures used to prepare filters for use. TO-13 is part of the EPA's compendium of Methods for the Determination of Toxic Organic Compounds in Ambient Air. This version was published in 1989. For future reference a new version, TO-13A was published in January 1997 and should be considered as a replacement for TO-13.
Response: Battelle 's application of Method TO-I 3 is restricted to the sections that describe the use of the PS-I air samplerfor collection of semi-volatile organic compounds (SVOC). The analytical methods described in TO-13 are not being applied to the analyses of the FCs of this study. Battelle will clari,rL thispoint infuture references.
The cleaningproceduresfor the PUF,Jilter, and holders are similar to methods usedfor other SVOC, and included Soxhlet extraction of PUF, solvent rinses ofjilters, and heat cleaning at 450Cfor holders. Field blanh and spikes of both theJilter and PUF media were used at each
site, so that individual site sample data may be evaluated in the context of these QC samples.
Comment l b (Air Sampling): Several specific sample set-up requirements were not followed (section 11.3 in TO-13). The sampler was not set up at least 2 meters from any obstacle (11.3.2). The sampler was placed approximately one foot away from a wall that could cause a flow obstruction. The sampler was not equipped with an exhaust hose to prevent recycling of air into the sampler head (11.3.2). A single point flow check was not performed as described in Section 11.2.3 of TO-13. Flow rates were varied from 55, 50,40,30and 20 inches of water using the voltage variator during set-up which is incorrect. It appeared that the five point flow variator adjustments were somehow thought to be the calibration procedure described in section 11.2of
TO-13. A thorough review of TO-13.TO-13Aare recommendedprior to conducting any further
ambient air testing relative to this study.
Response: Field crews were instructed to be discrete in theplacement of the air sampling equipment such that the sampler would be out of line-ofsight ofpassers-by and would not interfere with on-site operations. An additional consideration includedproximity to thepower source. In some cases these requirements resulted in the air sampler beingplaced less than 2 m
from a building. EachJield report includes information aboutproximity of the air sampler to a
building. Any air data will be evaluated in light of availableplacement information, with assessment ofpossible impacts.
An exhaust hose should have been used. This omission would be expected to result in slightly lower air concentrations than actual. A thorough review of$eld crew instructions, SOPS and equipment showed that multi-point checb wereperformed byfield stagas instructed in the project specijk SOPfor air sampling, which is based on TO-13. This approach is slightly
BACK TO MAIN
different@orn the TO-13 method because on thisprogram only one sample was being collected at each site (city), and the sampler was shipped, or driven, long distances between sampling sites. The initial sampler calibration (11.2.2 of TO-13) with the oriJce transfer standard was carried out at Battelle Duxbury prior to shipping the samplerfor each sampling trip. Then, at each site, a multi-point check was carried out, rather than a single point check. After a sampling trip, thefield-measured values determined in the multi-point check were compared against the initial calibration to verifi that thepercent difference between the readings was within range (<8% diference). This approach is actually a little more rigorous than TO-13, and was chosen because of the diference between this sampling regimen and the standardfixed-location sampling where multiple samples are collected over a longperiod of time.
The TO-13 instructionsfor carrying out a multi-point calibration, or check, indicate that the sampler 'ssflowcontrol valve and the voltage variator are both adjusted to give 5-6 diflerent
Magnehelic readings. Both devices, or either device, can be used to adjust theflow. The PS-1
samplers used in this study are equipped with an odofftype valve (1/4 turnfrom o#to on) and cannot be adjusted incrementally. Therefore, Battelle staff adjusted only the voltage variator to obtain the multi-point calibration or check.
Comment 2 (Air Sampling): There is concern that not enough methanol was used to rinse such that liquid methanol dripped off the sampler parts thus rinsing away potential contaminants. The methanol was evaporating nearly as fast as it was being applied. This would only redistribute potential contaminants rather than rinse them away. There is question as to why the air sampler was placed on the ground near the wall of the building.
Response: Battellefield staff have been notified of this concern and agreed to ensure that signijicant solvent run-off existed during all rinsing operations. The issue of sampler placement is discussed above. Note that this was, by design, an opportunistic sample, and would not necessarily conform to the siting criteria applied to locations usedfor long-term monitoring programs.
Comment 3 (Water Treatment plant): There is concern about possible residual accumulation
of FCs onto the surface of the flexible tubing. Some discussions regarding this concern are
warranted. For future reference, it may be advisable to remove any such tubing before sampling.
Response: Any material that was part of the site plumbing should be in equilibrium with the water with which it is in contact, and thus removal would not be necessary.
Comment 4 (Surface Water): The surface water and sediment samples were collected by wading into the shallows near shore. The process of wading stirred sediment from the bottom while water samples were being collected. The suggestion was made that Chris remain still and Kelly hand the bottles to him while he collected the water samples. This technique was used to collect the samples thereafter.
Response:Battellefield personnel are trained to sample "upstrearn"fiomsediment
perturbations caused by wading or shipboard activities wheneverpossible. Based on this
BACK TO MAIN
comment, thefield crew will sample surface water in thefuture with heightened awareness to sediment resuspension issues.
Comment 5 (POTW Sample): There is concern about possible residual accumulation of FCs onto the surface of the bucket (used for sampling at this site). Some discussions regarding this concern are warranted. For future reference it may be advisable for the sampling crew to provide a remote sampling apparatus such as a telescoping handle.
Response: Battelle has added a telescoping handle to itsfield gear to aid in the collection of samplesfrom confined and/or hard-to-reach areas, such as this POTW efluent collectionpoint. With regard to collection of the POTWsamples with an on-site bucket, conversations with the POlWstaff indicated that the bucket was permanently set up therefor sample collection, and thus it represented a passivated surface.
Comment 6 (Field Spiking): The addition of the empty vial to the sample raises concern. This procedure follows the QAPP but poses a potential contamination source, that being the outside of the vial. The QAPP specifies the vial be methanol rinsed and wiped dry with a Chem Wipe. What are the precautions that the external surfaces are kept from potential contamination?
Response: The outside of each vial was rinsed with methanol after the vial waspame-sealed in the laboratory. The loaded, sealed and cleaned vials were thenplaced in labelledpolyethylene zip-seal bagsfor transport to thefield. The vials were maintained in thepolyethylene bags until use. As an addedprecaution, the vials were solvent-rinsed before use. In the absence of extensivepre-testing of allfield protocols, thisprocedure was adopted as a reasonable and cautionary approach topreventing contamination. The "vialaddition" strategyfor spike addition to a liquid sample is a rapid and accurate way to add a spike in thefield. It provides a quick visual indication and confirmation that the spike solution has, indeed, been added. The addition of the vial assures that all material in the vial is added to the sample. The "vial addition ''strategy eliminates the use of syringes in thefield. This technique also eliminates the possibility of solvent evaporation and concentration changes that occur when a spike solution
vial is opened several times in the$eld.