Document dgzVedvDL0jkyaNdavd8YkXe
DCTARTMEKT OT rHYMOLOCY
HARVARD UNIVERSITY
SCHOOL OF PUBLIC HEALTH
aS HUNTINGTON AVENUE ^BOSTON* MASSACHUSETTS 021 IB
Kay 2, 1975
Hr. John P- Koval Superintendent . Norwood Hoofing Plant Bird Son East Walpole, MA- 02032
PLAINTIFF'S EXHIBIT
Dear Mr. Koval:
I enclose the results of the limited dust sampling and the sound level measurements. The values near the shingle cutter are high but no-one seems to work there.. Packaging is also noisy. You may want to consider using some deadening device or padding. The rock driers are noisy but very few men are exposed. It was suggested you might put some sound deadening material on the worker's booth to reduce the noise level even ore. Also you could look into the possibility of a less noisy vibrator in the sifting area which we believe was responsible for the "buzz".
Dust levels
Person
Job
Straus
Machine operator
Coumoyer
Base coating
Stahnke
Surfacing operator
All had less than 1% Silica.
April 9, 1975
Dust level 3
` 0.90mg/M 0.64mg/M3
0.84mg/M^
The threshold limit value (ACG 1H - 1974) is: 10mg/M3
.
--------------------------% Silica +2
- For this dust then TLV would be 5 to 3 mg/M .
The above measurements represent a rather brief time interval 1 to 3 hours and are also rather few in number. They do indicate that the dust exposures were not excessive.
BIRD 015003
15
BIRD 015002