Document dbjaND22DXZa257gEzyDznZQ
TISSUE RESIDUES FROM SUBACUTE ORAL FEEDING OF POLY CHLORINATED BIPHENYL DIELECTRIC FLUIDS
Robert G. Kaley, II, Orville Hicks, William M. Mees, E. Scott Tucker, Frederick R. Johannsen, and James
P. Mieure
Monsanto Company 800 N. Lindbergh Boulevard St. Louis, Mo. 63166
DSW3"S8i7
STLCOPCB4084280
Since the identification of polychlorinated bi phenyl (PCB) residues as environmental contaminants, numerous studies have investigated the uptake, distri bution, and depuration of PCB's in various organisms (HUTZINGER et al. 1974). It has been established that Idle lower chlorinated PCB's are readily biodegraded and that the more highly chlorinated homologs are increas ingly resistant to biodegradation (BAXTER et al. 1975, METCALF et al. 1974, TUCKER et al. 1975). Monsanto 'Company, the)| sol-o United Ctatesjjproducer of PCB fluids, marketed as Aroclor* products, has restricted sales to use in closed systems. Additionally a new product, Aroclor 1016, has been introduced. Aroclor 1016 con tains only about one tenth the level of the more resis tant penta- and hexachlorobiphenyls as the functionally similar product Aroclor 1242.
The purpose of the present study was to assess the tissue residue accumulation and depuration of Aroclor 1242 and Aroclor 1016 during a 30-day oral subacute ex posure to albino rats. Monochlorobiphenyl (MCBP) and a 30%-chlorinated product, MCS 1043, were included in this feeding study.
During the course of this study, other workers (BURSE et al. 1974) reported that Aroclor 1242 accumu lated to a lesser extent than Aroclor 1016 in rat tis sues. This result was somewhat unexpected since, as mentioned above, the only difference in the products is the level of the more resistant, more highly chlorina ted biphenyl homologs, as shown in Table I. It is these more highly chlorinated species which have been consistently reported as environmental residues in wildlife (POLYCHLORINATED BIPHENYLS AND THE ENVIRONMENT 1972). The feed levels in our study, 5 and 25 ppm, were chosen to be high enough to permit precise and accurate determination of residue levels but low enough to have minimal effect on the health of the rats* Burse et al. did report some morphological effect on the rats at the 100 ppm exposure level used in their study.
* Registered Trademark of Monsanto Company
OSW 345818
STLCOPCB4084281
TABLE I TYPICAL % COMPOSITION OF POLYCHLORINATED BIPHENYL PRODUCTS
HOMOLOG
MCBP
C1/BIPHENYL
0 ND
1 100
2 ND
3 ND
4 ND
5 ND
6 ND
7 ND
8 ND PER CENT (W/W) BY GC/MS
BY HOMOLOG RESPONSE
MCS
AROCLOR
AROCLOR
1043
1016 ,
1242
0.1
<0.1
<0.1
22 1
1
72 20
16
6 57
49
ND 21
25
ND 1
8
ND <0.1
1
ND ND
<0.1
ND ND
ND
USING AREA CORRECTION FACTORS
ND == NONE DETECTED, <0.01%
Experimental
Eight batches of feed were prepared by impregna ting Ralston Purina rat chow with the four products at two levels each. The treated chow was fed ad libitum to adult Sprague-Dawley. albino rats for an exposure period of 30 days. At predetermined intervals during the exposure period (days 2, 5, 10, 20, and 30) five rats from each set were sacrificed and fat, liver, and muscle tissues were excised for analysis. Following the 30-day exposure, all remaining rats were placed on the basal laboratory diet. At days 32,35, 45, 75, and 105 of the study (days 2, 5, 15, 45, and 75 of recovery) tissues were sampled in a manner identical to that used during exposure. Samples were composited and quickfrozen in glass containers with aluminum foil-lined caps to minimize risk of contamination. A control com posite of rats fed only the basal laboratory diet was collected at each sampling date to determine possible interferences in the analyses of the exposed animals. During the period that rats were fed PCB-containing rat chow, their food intake and body weight gains were similar to those of rats fed the basal laboratory diet alone.
Feeding, sacrifice, and tissue excision were car ried out at Younger Laboratories, Inc., St. Louis, Mo. The samples were delivered to our laboratories for sample clean-up and analysis.
The PCB residues were isolated from the tissues by solvent extraction. A weighed amount (approximately 10 g) of the composited tissue was placed in art Erlenmeyer flask and homogenized three times with 25 ml of pesticide grade hexanes and anhydrous sodium sulfate
DSW 345819
STLCOPCB4084282
using a Polytron ultrasonic homogenizer (Brinkmann In struments, Westbury, N.Y.). The combined supernatants and washings were filtered through anhydrous sodium sulfate and diluted to 100 ml with pesticide grade hexanes.
A 5 ml aliquot of the hexanes solution was pipet ted onto an alumina column (TUCKER et al. 1975) and the PCB's were eluted with 125 ml of pesticide grade hex anes. The column eluent was collected in a KudernaDanish evaporative concentrator, a 3-ball Snyder con denser was attached, and the solution was concentrated for electron capture gas chromatographic analysis. The gas chromatographic conditions are listed in Table II.
TABLE II
Instrument:
Column:
Temperatures: Injection Port: Detector: Column:
Carrier Gas: Purge Gas: Pulse Interval:
Hewlett-Packard 5753A Research Gas Chromatograph (Ni-63 Pulsed Electron Capture Detector) 2 m X 1/4" glass column packed with 4% XE-60 on 80/100 mesh Chromosorb W-HP
230 C 300 C 140 C Isothermal for MCBP and
MCS 1043 170 C Isothermal for Aroclor
1016 and Aroclor 1242 Helium, 60 ml/min 10% Methane in Argon, 120 ml/min 50 microsec
A second 5 ml aliquot of the extract solution was pipetted into a tared 50 ml beaker. After evaporation of the solvent under a stream of nitrogen, the beaker and residue were reweighed to obtain the lipid weight of the aliquot. All residue levels are reported as parts per million (ppm) on a lipid weight basis.
Calibration curves for each product were prepared by plotting detector response (total peak area) versus nanograms of material injected. Residue levels were determined by summation of the total area of the'PCB peaks in the sample and use of the appropriate calibra tion curve. The calculations were done as follows:
Residue (ppm)' = (N) (Vp) (Vi) (W)
Where N = amount of PCB from calibration curve (ng)
DSW 345820
STLCOPCB4084283
Vp = volume of final concentrate (ml) Vj = volume injected (ul) W = lipid weight of original sample (g).
Results and Discussion Plots of the data for the PCB lipid residues for the chlorinated biphenyl products are shown in Figure 1. The values plotted represent the levels of each product found in the adipose tissue, calculated on a lipid weight basis.
Ul MONOCHLOROBIPHENYL
(cl AROCLOR 1242
TIME (DAYS! Ul AROCLOR 1016
Figure 1: Adipose Tissue Residue Level Versus Time Plots for Products Investigated
DSW 345821
STLCOPCB4084284
The test error associated with the data points of Figure 1 was evaluated using the logarithms of the data points' for which replicate determinations were per formed. The 95% confidence limits for the determination of Aroclor 1016 and Aroclor 1242 were calculated to be 79% to 126% of the observed value of a data point. In the case of MCBP and MCS 1043 the test error limits were calculated to be 63% to 160% of the observed value.
MCBP was fed at levels of 25 and 100 ppm. Figure la shows that MCBP immediately reached a relatively stable level of about 3 ppm for the low feed level and 9 ppm for the high feed level when feeding began. These levels were maintained throughout the 30-day exposure period. Upon removal of the impregnated feed, the tis sue residue levels dropped to such low levels that no MCBP was detected in fat extracts five days after ces sation of exposure. MCBP thus showed no tendency to accumulate or be retained in the fat tissue.
When fed to rats at the same levels as MCBP, the behavior of MCS 1043 was similar to that of MCBP. It reached a plateau immediately upon initiation of feed ing and maintained that level throughout the exposure period. This behavior is shown in Figure lb. Upon cessation of exposure the level of MCS 1043 in fat rapidly dropped to such an extent that it was not de tected after 15 days of the recovery period.
Figure lc is the plots of the residue levels for the 5 and 25 ppm feed levels for Aroclor 1242. The curves indicate that Aroclor 1242 accumulated in the fat and continued to build up throughout the exposure period. The shape of the build-up curve suggests, however, that a plateau level was being approached. Upon removal of the impregnated feed, the Aroclor 1242 level in the tissues declined rapidly. However, at day 75 of the recovery period, detectable levels of Aroclor 1242 remained in the tissues. The residues in the tis sues sampled after the exposure period consisted of the more highly chlorinated homologs, as discussed below.
The plots of the residue levels for Aroclor 1016 are shown in Figure Id. Aroclor 1016 accumulated more slowly than Aroclor 1242 during exposure and declined rapidly during recovery. Low levels of Aroclor 1016 remained in the tissues through day 75 of the recovery period.
Figure 2 emphasizes the differences in response to the feeding of the products at the same dietary level. The difference in the behavior of MCS 1043 is obvious, since it did not accumulate and rapidly declined to
DSW 345822
STLCOPCB4084285
below the detection limit upon restoration of the basal laboratory diet.
Figure 2: Adipose Tissue Residue Level Versus Time Plots for Aroclor 1242, Aroclor 1016 and MCS 1043 at 25 ppm Feed Level
As shown in Figure 2 the residue levels of Aroclor
1016 were lower than those of Aroclor 1242. A test was
made to see if this difference was statistically signi
ficant based on the estimated precision of the deter
minations. The 95% confidence limits for Aroclor 1242
and Aroclor 1016 (79-126%) were superimposed on theore
tical accumulation and recovery plots (based on multi
ple regression analysis of the actual data) for the
two products. These plots are shown in Figures 3a
and 3b. The difference in residue levels for the two
products is statistically significant at the 95% confi
dence level where the superimposed error limits on the
regression curves do not overlap. As can be seen from
the graphs, at day 17 of the study the difference be
tween the residue levels of Aroclor 1016 and Aroclor
1242 became significant and remained so throughout the
remainder of the exposure period and the entire recov
ery period. Thus, this study shows a significant dif
ference in the tissue residue levels of Aroclor 1016
and Aroclor 1242.
'
dSnN 345823
STLCOPCB4084286
til RECOVERY
Figure 3: Regression Curves for Accumulation and Re covery with Superimposed Error Limits for Aroclor 1242 and Aroclor 1016
Figures 4a and 4b are chromatograms of the extracts of the feed and fat tissue (30-day exposure samples) for Aroclor 1242 and Aroclor 1016, respectively. The chro matograms for Aroclor 1242 show that most of the early peaks in the extract of the feed have disappeared or decreased in relative size, indicating that the corres ponding components were not retained in the tissue. These peaks correspond to PCB homologs with a low de gree of chlorination, i.e., di- and trichlorobiphenyls. Some peaks corresponding to more highly chlorinated homologs increased in relative size, indicating a great er tendency for these homologs to accumulate. However, it should be noted that since relative electron capture detector response increases with increasing chlorine substitution on the biphenyl molecule, a peak corres ponding to a tetra-homolog, for example, results from a much smaller absolute amount of PCB than a peak of equal area corresponding to a di-homolog.
In the chromatograms for the Aroclor 1016 extracts shown in Figure 4b, there is exact correspondence of peaks in the early portions of the feed and fat chro matograms with peaks in the Aroclor 1242 chromatograms. The chromatograms differ markedly, however, in the re gion where the more highly chlorinated homologs elute. Examination of the 30-day exposure chromatogram for Aroclor 1016 shows that there was no accumulation of more highly chlorinated homologs analogous to that noted for Aroclor 1242.
DSW 345824
STLCOPCB4084287
DETECTOR RESPONSE
Figure 4: Chromatograms of Feed and Tissue Extracts of Aroclor 1242 and Aroclor 1016
Since no persistent residues of MCBP or MCS 1043 were detected in fat during this study, no chromato grams for these products are shown.
Liver and muscle tissues from the 30-day high feed ing level of each material were also analyzed. The data for these analyses are shown in Table XXI.
TABLE III 30-DAY EXPOSURE LIVER, MUSCLE, AND FAT
RESIDUE LEVELS (LIPID WEIGHT BASIS)
Product
Feed Level (ppm)
Muscle (ppm)
Liver (ppm)
Fat (ppm)
MCBP MCS 1043 Aroclor 1242 Aroclor 1016
100 100
25 25
7.4 8.4 42.0 31.3
9.1 15.9 60.4 46.3
6.4 11.5 37.3 22.7
DSW 345825
...
STLCOPCB4084288
Summary
The results of this study can be summarized as follows: (1) Monochlorobiphenyl and the 30%-chlorinated biphenyl MCS 1043 did not accumulate in the lipid reservoir of the rats when fed at 25 ppm and 100 ppm in the diet. This result indicates that mono-, di-, and trichlorobiphenyls are readily metabolized and/or excreted under the conditions of this study. (2) Although a fraction of the ingested Aroclor 1242 and Aroclor 1016 was stored in the rats' lipid reser voir, most of this residue was depleted after the rats had been on the basal laboratory diet for several weeks. (3) Residues of Aroclor 1016 accumulated more slowly and to a significantly lesser extent than those of Aroclor 1242. During the recovery period these PCB residues decreased to lower values for Aroclor 1016. This result substantiates the improved environmental compatability for a product containing reduced amounts of the more highly chlorinated PCB's,
Acknowledgment
The authors wish to thank J. D. Hinchen for the statis tical treatment of the data.
References
BAXTER, R. A., et al. , Sci. Total Environ., 4^, 53 (1975).
BURSE, V. W., et al. , Arch. Environ. Health, 29^, 301 (1974).
HUTZINGER, O., SAFE, S., and ZITKO, V. , The Chemistry of PCB's, Cleveland, CRC Press, 1974.
METCALF, R. L., et al., Arch. Environ. Contam. Toxicol,, 3, 151 (1975).
POLYCHLORINATED BIPHENYLS AND THE ENVIRONMENT, National
Technical Information Service, U. S. Department of
Commerce, Springfield, Virginia 22151, (1972).
COM-72-10419.
-
TUCKER, E. S., et al., Bull. Environ. Contam. Toxicol., Accepted for Publication, (1975).
DSW 345826
STLCOPCB4084289