Document daryY2Bdz8G0KwReQJyK81GyQ
gas fired boilers hot water or steam
new G>40 gas boiler--reduces costs and installation time
The new G-40 gas boiler by American-Standard is suit able for installation in larger residences and small apart ment and commercial buildings. Designed for both hot water and steam installations, It can be furnished with a tankless type, internal, domestic water heater for either application. An attractive two-tone boiler jacket gives the G-40 a clean, streamlined appearance.
Ruggedly constructed of durable cast iron, the new G-40 is available in 3 to 10 section sizes with A.GJI design certified outputs from 120,000 to 540,000 btu.'hr. All sections are tested for 50 psi water working pressure. On-site assembling time can be decreased by ordering
up tolOsections pre-essembled. With or without factoryinstalled tankless heater. An exclusive built-in air diminator-the EUMINAIRE-Is furnished on all boilers, specifically for hot water installations, saving the addi tional expense of an external device.
The G-40 is provided with two 3* top flow tappings and two 2Vi" return flow tappings to allow flexibility in de signing system piping when the G-40 is installed in con fined areas. Ear further convenience, complete manifold and all controls are shipped factory assembled. Selfenergizing controls and electronic controls are available as options.
1-Eliminate *-is a patented cost-saving feature of the G-40. This unique built-in air eliminator is integrally cast into the left hand end section. Furnished in all boilers specifically for hot water installations, the ELIMINAIRE baffle diverts rising air bub bles into a tapping for connection to the expansion tank. No external device is required to separate air and water-thus reducing both costs and installation time..
2-controls-mounted on front and -left side of boiler for easy adjustment and mainte nance. Optional electronic controls and selfenergizing controls available.
3-wster heater-targe, finned copper coil tankless type available for steam or water installations. Inserted where hottest water is in contact with heater coil.
4-tappings-two 3* supply (top) and two 2V4' return tappings (side) simplify piping hook-up.
5-jacket-sturdy steel with smart beige and brown finish, modem radius corners. Inner surfaces protected with heavy glass fiber insuletion-prevents wasteful heat loss, keeps jacket cool.
t-built-ir, draft hood--completely enclosed in jacket; eliminates unsightly protrusion in rear of boiler.
7-east iron sections-multiple pin-like pro jections for maximum heat extraction. Tested fsr 59 psi water working pressure. End sestions designed with extended legs to elim inate need for separate base.
I--burners-precition made and factory tested to essure quiet, efficient operation with all gases. Cast iron, drilled port burners supplied for natural and mixed gases. Cleanable ribbon burners standard for LP gas.
9-faetery assembled manifold and controls -only requires attachment to boiler. Com pletely enclosed by jacket.
CLIMirMlRC* It t trademark of AMERICAN STANDARD Inc.
G-40 ratings (natural, mixed and LP gases)
( ior installations from ssa leva! to 2000 ft a
beiltr number
ns. if stetiens
ne. if burners
A.6.A. ratings
Input (Btu/hr>
aulput (tu/hr)
net Islzl ratingi a
water (Btu/hr)
stsam (*q-tU
steam (8 tu/hr)
chinin*y
diameter (inches)
height (feet)
G-403 0-404 G-403
fi-406 G-407 G-40*
G-409 G-4010
32
43 54
6S 76
a7 9a
10 | 9
130,000 323,000 300.000 373,000 430,000 323,000 600,000 673,000
120,000 180,000 240,000 300,000 360,000 420,000 480,000 540,000
104,300 156,300 208,700 260,900 313,000 365,200 417,400 469,600
373 563 750 938 1123 1313 1500 1688
90,000 133,000 180.000 225,100 270,100 315,100 360,100 405.100
6 7 8 9 10 10 12 12
For altitudes abort 2000 ft., ratino mould bo raducad at tna rata of 4% for tacit 1000 ft. about aaa laral. A Nat laid ratings Mown art bated an a piping and pick up allowance of IJ3S for steam and 1.19 for water. American-Standard
tnowld be consulted balora selecting a boiler for installations having unusual piping and pick up requirements.
IS 15 IS 15 IS IS 15 IS
G-40 tankless heater ratings
100'F rite in ttmptrpturt with 300*F boiler water temperature (gallons per minute)
boiler number
G-403 G-4S4 G-403 G-406 G-407 Ej*4w8 G-409 G-4010
hsatsr no. 218
water
steam
43 4 314 4 3*
4 3 4 314 4 31i 4 314 4 314
water
414 414 414 414 4V4 4Vs 414
steam
4 4 4 4 4 4 4
hseter ns. 228
water
stsam
__
6 514 6 614 8 614 6 614 6 614 6
heater no. 232
wetor
-- -- -- 714 8 8 8
steam
_
__
--u 7 714 714 714
MOTE: Domestic Mol wstsr Connection Sint-h* for hsstsr nos. 211.212. 224. 2X2 and v lor no. 4S.
water
_
__ -- -- --
9 9 9
steam
_
-- 8V4 814 814
G-40 fas boilers by American-Standard have ratings spproved by the Institute of Boiler and Radiator Manufacturers. The boilers are constructed to the specifications of the American Society of Mechanical Engineers and are design certified by the American Gas Association for all gases. The G-40 bears the l=B=R, A.S.M.E. and A.G-A. symbols. All sizes of the G-40 are available in models for foretd and gravity hot water, and steam systems.
sample specification for G-40
Contractor shall furnish snd install, as indicated on plena, --......... gas fired boilerfs), having an input of............ Btuh and a gross output of............ Btuh when fired with.............
gas. Boiler(s) shell be constructed of cast iron in accord ance with A.S.M.E. requirements for low pressure heating-
boilers and bear the A.M.E. symbol. Boiler(s) shall be ^C-A. design certified end have l=B=R approved ratings. Boilerfs) shall be furnished with an air elimination device integrally cast into the left hand and supply tapping. Boiler(s) shall be composed of cast iron sections with ver tical flues and furnished with one atmospheric drill port
or removable ribbon burner per flueway. Boiler(s) shall be supplied by manufacturer with one main automatic dia phragm ga* valve, safety pilot with thermocouple end
additional lighting pilots as required, one gas pressure regulator (except (or LP. gas), high limit control, and in tegral canopy and drafthood. Water or steam trim as required.
Boilerfs) shall be supplied with internal type tankless heater capable of supplying...............gallons per minute at a 100*F rise in temperature.
3
l minimum piping recommendations
hot water
steam
gas fired boilers
bailtr numbr
C-03 0-404 C-405 0-406 0-407
riser OnJ
raturn htadar equal-
tin.)
On.)
tear On.)
21
IV*
2Vi 1
-- lVi
2V* 1
-- IV*
3 IV* -- IV*
3 iv* -- IV*
boiltr number
jravity
supply riturn (in.) (in.)
G-403 C-4C4 0-405 0-406 0-407 G-4C8 C-409 G-4010
2 2 2V*
131-2 (21-2 (21-2 (2V2Vi
(2)-2Vi
2 and 2V* (2J-2 (21-2 (21-2 (2!-2V* (2i-2V
tsread
aupply rtlurn (in.) On.)
IV* IV* IV* IV. IV* IV* 22 22 22 2V* 2V* 2V* 2V*
NOTE: Left hand supply connection featuring the ELIMINATE* it used on water boilers. Limit control snow'd also Do pieced in the left nand sect,on. Whore Doth outlets end return or* used
en gravity systems, make respective supply end return connection at opposite ends of lha boiler.
gas control and connection sizes; pertinent data
boiler number
G-CC3 0-404 G-405 0-406 G-407 0-408 G-409 G-4010
atar eantanl (paunda)
aratar
220.8 281.0 341.2 401.4 461.6 521.1 S82.0 642.2
ataam
164.4 209.9 255.4 300.9 346.4 391.9 437.4 482.9
appra*. wai(M (paunda)
858 1027 1195 1370 1544 1713 1880 2050
aixa af manilald Onchtal
ntL.mid.l LPfaata
IV* IV* IV* IV* IV* IV* IV* IV*
praaaura npulatara Onchtal
Mt
V* 4* 4* 1 1 1 1 IV*'
mad.
4* 4* 1 I IV* IV* IV* IV*
Pressure regulator not furnished for LP gates.
autamatic gaa valva, |ia cannactiana and manual ahutaff valta alaaa (inchaa)
Mt mid. LP
V* 4* 4* 1 1 1 1 IV*
4* 4* 1 1 IV* IV* IV* IV*
V* V* V* V* 4* 4* 4* 44
AMERICAN STANDARD
nuMUNr A Hf ATiwr nivumw
dimensions for drafthood outlets
dimensions for inlets and outlets
boilor tiumbor
A
inlots--outlits dimensions (inches)
8C0C F
G-403
avi 7H 6%
9% 2%
6-404 10*. 10% 6% 14
3%
6-405 12V4 12% 6V4 18% 3%
6-406 IS 154* 6% 23
4%
6-407 17Vi 17% 544 27% 4%
6-408 19% 20% 544 32
4%
G-409 21V* 22H 6V4 36% 4%
G-4010 24
24% 6V4 41
4%
6 7 8 9
--
--
--
--
L
15% 20% 2S% 30% 35% 39% 44% 48%
gas fired boilers
ftoiltr number
droftfiood outlots dimension* (Inches)
e
M dl.
i
K
G-403 G-404 6-405
G-406 6-407 6-408 6-409 6-4010
644 644 6% 6% 544 544
CM
5% 6% TK 8% -- --
--
--
--
----
----
----
a HVi 8 im 9 14H 9 14%
flu* pipe dltmofor (Inches)
5 7 8 9 10 10 12 12
rtK Mw
Itftsfelvttw
orifice drill sizes--main burner spuds (at sea level)
Input
natural ond mixed gooes
($tt
LF pee*
por specific 800 too 1000 1100 1200 (00 (SO 700 750 800 2S00 3300
humor gravity atu tat tv tu Btu tu Btu Btu Btu tu tu Btu (8tub) of (00 eg. ft tiea eu. ft. M.H. it. a u.a u.a a. a eu.ft. cu.fl u.a u.a
75.000 0.60 X. IS 19 21 24
75,000 0.65 11 15 18 20 -- -- _ --
75,000 0.70 10 14 17 19 21 A 2 3 4
75,000 0.80 -- -- -- -- -- C 1 2 3
75.000 0.90
D81 2
75,000
75,000 2.00
__
7 4 3 --.
39 43
NGTfc See level rating* nlobt used tor elevations between 0 end IM ft. For altitudes above 2.BOO ft. see level ratings should bo roducod tt tho rate of 4% for toch 1400 ft above soo ItnL
manifold pressure table
man ifeld
p
heating value*
prtsturt On. HaO)
net A mxd 00-1200 .3.5
l> 2500 4 3300 11.0 UW|{| pi 800-800 . 3.0
heeling value 0* gas at ees level
(M*F and 30 In. Hg.)
AMERICAN STANDARD 5
FlUMBINC* MEATINC DIVISION
gas fired boilers
f assemblage of sections | control tappings
J ssaemblagt el aactiena
bailer number
na. af atciieni
dimtnzienz (tnchaa) LK
G-403
3 13 9VS
S-404
4
17Vb
14
C-405
5 22 ISIS
G-406
6
26Vi
23
G-407
7 31 27VS
0408 G-409 G-4010
8 9 10
35Vb 40 44 VS
32
36Vb 41
r
iacalian A
cantrst tapping! (iltam)
aiza ef tapping! (in.)
csnlral uaed
VS pressure pu|i
B 1VS
blow-off a
C 44 tanklaaa haatar control
D1
aaftty valve
VS
(tufa glaee and low watar cut-off
when reewi d.suailisry limit ce ntrol is to be installed fciOO'Off (tipml.
lecation f 6
H
j
control lappinti (hat water)
aixe af tapping! Gn.)
central uaad
VS
temperature and altitude flute
VS auxiliary limit control
combination operating, high limit and low voltage relay immeraion
control (for inatallotion with *4 tanklces water heater)
limit control - (for installation without tank leas watar haatar)
1 praaaura relief valve
AMERICAN STANDARD plumbing & HEATING DIVISION
<0 WfST 40TH STREFT NW YORK, N.Y. 10018