Document daryY2Bdz8G0KwReQJyK81GyQ

gas fired boilers hot water or steam new G>40 gas boiler--reduces costs and installation time The new G-40 gas boiler by American-Standard is suit able for installation in larger residences and small apart ment and commercial buildings. Designed for both hot water and steam installations, It can be furnished with a tankless type, internal, domestic water heater for either application. An attractive two-tone boiler jacket gives the G-40 a clean, streamlined appearance. Ruggedly constructed of durable cast iron, the new G-40 is available in 3 to 10 section sizes with A.GJI design certified outputs from 120,000 to 540,000 btu.'hr. All sections are tested for 50 psi water working pressure. On-site assembling time can be decreased by ordering up tolOsections pre-essembled. With or without factoryinstalled tankless heater. An exclusive built-in air diminator-the EUMINAIRE-Is furnished on all boilers, specifically for hot water installations, saving the addi tional expense of an external device. The G-40 is provided with two 3* top flow tappings and two 2Vi" return flow tappings to allow flexibility in de signing system piping when the G-40 is installed in con fined areas. Ear further convenience, complete manifold and all controls are shipped factory assembled. Selfenergizing controls and electronic controls are available as options. 1-Eliminate *-is a patented cost-saving feature of the G-40. This unique built-in air eliminator is integrally cast into the left hand end section. Furnished in all boilers specifically for hot water installations, the ELIMINAIRE baffle diverts rising air bub bles into a tapping for connection to the expansion tank. No external device is required to separate air and water-thus reducing both costs and installation time.. 2-controls-mounted on front and -left side of boiler for easy adjustment and mainte nance. Optional electronic controls and selfenergizing controls available. 3-wster heater-targe, finned copper coil tankless type available for steam or water installations. Inserted where hottest water is in contact with heater coil. 4-tappings-two 3* supply (top) and two 2V4' return tappings (side) simplify piping hook-up. 5-jacket-sturdy steel with smart beige and brown finish, modem radius corners. Inner surfaces protected with heavy glass fiber insuletion-prevents wasteful heat loss, keeps jacket cool. t-built-ir, draft hood--completely enclosed in jacket; eliminates unsightly protrusion in rear of boiler. 7-east iron sections-multiple pin-like pro jections for maximum heat extraction. Tested fsr 59 psi water working pressure. End sestions designed with extended legs to elim inate need for separate base. I--burners-precition made and factory tested to essure quiet, efficient operation with all gases. Cast iron, drilled port burners supplied for natural and mixed gases. Cleanable ribbon burners standard for LP gas. 9-faetery assembled manifold and controls -only requires attachment to boiler. Com pletely enclosed by jacket. CLIMirMlRC* It t trademark of AMERICAN STANDARD Inc. G-40 ratings (natural, mixed and LP gases) ( ior installations from ssa leva! to 2000 ft a beiltr number ns. if stetiens ne. if burners A.6.A. ratings Input (Btu/hr> aulput (tu/hr) net Islzl ratingi a water (Btu/hr) stsam (*q-tU steam (8 tu/hr) chinin*y diameter (inches) height (feet) G-403 0-404 G-403 fi-406 G-407 G-40* G-409 G-4010 32 43 54 6S 76 a7 9a 10 | 9 130,000 323,000 300.000 373,000 430,000 323,000 600,000 673,000 120,000 180,000 240,000 300,000 360,000 420,000 480,000 540,000 104,300 156,300 208,700 260,900 313,000 365,200 417,400 469,600 373 563 750 938 1123 1313 1500 1688 90,000 133,000 180.000 225,100 270,100 315,100 360,100 405.100 6 7 8 9 10 10 12 12 For altitudes abort 2000 ft., ratino mould bo raducad at tna rata of 4% for tacit 1000 ft. about aaa laral. A Nat laid ratings Mown art bated an a piping and pick up allowance of IJ3S for steam and 1.19 for water. American-Standard tnowld be consulted balora selecting a boiler for installations having unusual piping and pick up requirements. IS 15 IS 15 IS IS 15 IS G-40 tankless heater ratings 100'F rite in ttmptrpturt with 300*F boiler water temperature (gallons per minute) boiler number G-403 G-4S4 G-403 G-406 G-407 Ej*4w8 G-409 G-4010 hsatsr no. 218 water steam 43 4 314 4 3* 4 3 4 314 4 31i 4 314 4 314 water 414 414 414 414 4V4 4Vs 414 steam 4 4 4 4 4 4 4 hseter ns. 228 water stsam __ 6 514 6 614 8 614 6 614 6 614 6 heater no. 232 wetor -- -- -- 714 8 8 8 steam _ __ --u 7 714 714 714 MOTE: Domestic Mol wstsr Connection Sint-h* for hsstsr nos. 211.212. 224. 2X2 and v lor no. 4S. water _ __ -- -- -- 9 9 9 steam _ -- 8V4 814 814 G-40 fas boilers by American-Standard have ratings spproved by the Institute of Boiler and Radiator Manufacturers. The boilers are constructed to the specifications of the American Society of Mechanical Engineers and are design certified by the American Gas Association for all gases. The G-40 bears the l=B=R, A.S.M.E. and A.G-A. symbols. All sizes of the G-40 are available in models for foretd and gravity hot water, and steam systems. sample specification for G-40 Contractor shall furnish snd install, as indicated on plena, --......... gas fired boilerfs), having an input of............ Btuh and a gross output of............ Btuh when fired with............. gas. Boiler(s) shell be constructed of cast iron in accord ance with A.S.M.E. requirements for low pressure heating- boilers and bear the A.M.E. symbol. Boiler(s) shall be ^C-A. design certified end have l=B=R approved ratings. Boilerfs) shall be furnished with an air elimination device integrally cast into the left hand and supply tapping. Boiler(s) shall be composed of cast iron sections with ver tical flues and furnished with one atmospheric drill port or removable ribbon burner per flueway. Boiler(s) shall be supplied by manufacturer with one main automatic dia phragm ga* valve, safety pilot with thermocouple end additional lighting pilots as required, one gas pressure regulator (except (or LP. gas), high limit control, and in tegral canopy and drafthood. Water or steam trim as required. Boilerfs) shall be supplied with internal type tankless heater capable of supplying...............gallons per minute at a 100*F rise in temperature. 3 l minimum piping recommendations hot water steam gas fired boilers bailtr numbr C-03 0-404 C-405 0-406 0-407 riser OnJ raturn htadar equal- tin.) On.) tear On.) 21 IV* 2Vi 1 -- lVi 2V* 1 -- IV* 3 IV* -- IV* 3 iv* -- IV* boiltr number jravity supply riturn (in.) (in.) G-403 C-4C4 0-405 0-406 0-407 G-4C8 C-409 G-4010 2 2 2V* 131-2 (21-2 (21-2 (2V2Vi (2)-2Vi 2 and 2V* (2J-2 (21-2 (21-2 (2!-2V* (2i-2V tsread aupply rtlurn (in.) On.) IV* IV* IV* IV. IV* IV* 22 22 22 2V* 2V* 2V* 2V* NOTE: Left hand supply connection featuring the ELIMINATE* it used on water boilers. Limit control snow'd also Do pieced in the left nand sect,on. Whore Doth outlets end return or* used en gravity systems, make respective supply end return connection at opposite ends of lha boiler. gas control and connection sizes; pertinent data boiler number G-CC3 0-404 G-405 0-406 G-407 0-408 G-409 G-4010 atar eantanl (paunda) aratar 220.8 281.0 341.2 401.4 461.6 521.1 S82.0 642.2 ataam 164.4 209.9 255.4 300.9 346.4 391.9 437.4 482.9 appra*. wai(M (paunda) 858 1027 1195 1370 1544 1713 1880 2050 aixa af manilald Onchtal ntL.mid.l LPfaata IV* IV* IV* IV* IV* IV* IV* IV* praaaura npulatara Onchtal Mt V* 4* 4* 1 1 1 1 IV*' mad. 4* 4* 1 I IV* IV* IV* IV* Pressure regulator not furnished for LP gates. autamatic gaa valva, |ia cannactiana and manual ahutaff valta alaaa (inchaa) Mt mid. LP V* 4* 4* 1 1 1 1 IV* 4* 4* 1 1 IV* IV* IV* IV* V* V* V* V* 4* 4* 4* 44 AMERICAN STANDARD nuMUNr A Hf ATiwr nivumw dimensions for drafthood outlets dimensions for inlets and outlets boilor tiumbor A inlots--outlits dimensions (inches) 8C0C F G-403 avi 7H 6% 9% 2% 6-404 10*. 10% 6% 14 3% 6-405 12V4 12% 6V4 18% 3% 6-406 IS 154* 6% 23 4% 6-407 17Vi 17% 544 27% 4% 6-408 19% 20% 544 32 4% G-409 21V* 22H 6V4 36% 4% G-4010 24 24% 6V4 41 4% 6 7 8 9 -- -- -- -- L 15% 20% 2S% 30% 35% 39% 44% 48% gas fired boilers ftoiltr number droftfiood outlots dimension* (Inches) e M dl. i K G-403 G-404 6-405 G-406 6-407 6-408 6-409 6-4010 644 644 6% 6% 544 544 CM 5% 6% TK 8% -- -- -- -- -- ---- ---- ---- a HVi 8 im 9 14H 9 14% flu* pipe dltmofor (Inches) 5 7 8 9 10 10 12 12 rtK Mw Itftsfelvttw orifice drill sizes--main burner spuds (at sea level) Input natural ond mixed gooes ($tt LF pee* por specific 800 too 1000 1100 1200 (00 (SO 700 750 800 2S00 3300 humor gravity atu tat tv tu Btu tu Btu Btu Btu tu tu Btu (8tub) of (00 eg. ft tiea eu. ft. M.H. it. a u.a u.a a. a eu.ft. cu.fl u.a u.a 75.000 0.60 X. IS 19 21 24 75,000 0.65 11 15 18 20 -- -- _ -- 75,000 0.70 10 14 17 19 21 A 2 3 4 75,000 0.80 -- -- -- -- -- C 1 2 3 75.000 0.90 D81 2 75,000 75,000 2.00 __ 7 4 3 --. 39 43 NGTfc See level rating* nlobt used tor elevations between 0 end IM ft. For altitudes above 2.BOO ft. see level ratings should bo roducod tt tho rate of 4% for toch 1400 ft above soo ItnL manifold pressure table man ifeld p heating value* prtsturt On. HaO) net A mxd 00-1200 .3.5 l> 2500 4 3300 11.0 UW|{| pi 800-800 . 3.0 heeling value 0* gas at ees level (M*F and 30 In. Hg.) AMERICAN STANDARD 5 FlUMBINC* MEATINC DIVISION gas fired boilers f assemblage of sections | control tappings J ssaemblagt el aactiena bailer number na. af atciieni dimtnzienz (tnchaa) LK G-403 3 13 9VS S-404 4 17Vb 14 C-405 5 22 ISIS G-406 6 26Vi 23 G-407 7 31 27VS 0408 G-409 G-4010 8 9 10 35Vb 40 44 VS 32 36Vb 41 r iacalian A cantrst tapping! (iltam) aiza ef tapping! (in.) csnlral uaed VS pressure pu|i B 1VS blow-off a C 44 tanklaaa haatar control D1 aaftty valve VS (tufa glaee and low watar cut-off when reewi d.suailisry limit ce ntrol is to be installed fciOO'Off (tipml. lecation f 6 H j control lappinti (hat water) aixe af tapping! Gn.) central uaad VS temperature and altitude flute VS auxiliary limit control combination operating, high limit and low voltage relay immeraion control (for inatallotion with *4 tanklces water heater) limit control - (for installation without tank leas watar haatar) 1 praaaura relief valve AMERICAN STANDARD plumbing & HEATING DIVISION <0 WfST 40TH STREFT NW YORK, N.Y. 10018