HEATING VENTILATING AIR CONDITIONING CUIDE 1942
The factors in Table 4, as corrected if necessary, are satisfactory for regions having 3500 to 6500 degree-days per heating season. In regions with less than 3500 degree-days the unit gas consumption is higher than given; where over 6500, the unit is less than given. Ten per cent addition or deduction in these cases is recommended by AGA publications.
For gas heating values other than those given in Table 4, simply inter polate or extrapolate. It will also be noted that Table 4 applies only to small installations. In general the larger the installation the smaller the unit gas consumption becomes and the values in the table should be used with care, if at all, in large gas-burning installations.
Example 7. Make an estimate of the gas required to heat a building located in Chicago, 111., assuming that the calculated heating surface requirements are 1000 sq ft of hot water radiation based on design temperature of 0 F and 70 F. Chicago has 800 Btu muted gas, and 6027 degree-days.
Solution. Using Equation 3 and Table 4, the fuel consumption for a design tem perature of 0 F with 800 Btu gas is found to be 0.085 cu ft of gas per degree-day per square foot of hot water radiation.
0.085 X 1000 X 6027. = 512,295 cu ft.
Estimating Oil Consumption Unit fuel consumption factors for oil, similar to those for gas in Table 4
are given in Table 6. The factors in Table 6 apply only to an inside design
Table 4. Factors for Estimating Gas Consumption3
Hot Water
Steam
Warm AIB
Btu Value of Gas
pbb Cu Ft
Cu Ft Gas per Degree-Day per Sq Ft Radiator
Up to 500
Sq Ft
500 to 1200
Sq Ft
Over 1200
Sq Ft
Cu Ft Gaa per Degree-Day per Sq Ft Radiator
Up to
500 Sq Ft
300 to 700 Sq Ft
Over 700
Sq Ft
Cu Ft Gaa per Degree-Day per 1000 Btu Hourly Design Heat Loss
Gravity Fan Systems
500 535 800 1000
0.142 0.132 0.089 0.071
0.135 0.126 0.085 0.068
0.128 0.120
0.081 0.065
0.242
0.226
0.151 0.121
0.231 0.215 0.144 0.115
0.220 0.2060.137 0.110
0.855 0.800 0.534 0.428
0.820 0.766 0.513 0.410
1 Therm
100,000 Btu
Gas Consumption in Therms per Degree-Day 0.000708 0.000675 0.000642 0.00121 0.00115 0.00110 0.00428
0.00409
Abstracted from Comfort Heating, American Gas Association, 1938.
Table 5. Correction Factors for Outside Design Temperatures
FOutside Desiqn Temp. Deo
FInside Design Temp, Deo
Mui/rm/r Values in Tables 4, 6 and 7 bt
-20 -10
0 +10 +20
70
70 70 70
70
0.778
0.875 0.000 1.167 1.400
230
CHAPTER 11. HEAT AND FUEL UTILIZATION
temperature of 70 F and an outside design temperature of OF. For other outside design temperatures, the constants in Table 6 must be multiplied by the values in Table 5 as explained under Estimating Gas Consumption.
Table 6 assumes the use of oil with a heating value of 140,000 Btu per gallon. For other heating values, multiply the values in Table 6 by the ratio of 140,000 divided by the heating value per gallon of fuel being used.
Example 8. What would be the estimated seasonal oil consumption of a boilerburner unit in Minneapolis of a building having a calculated heat loss of 192,000 Btu per hour, burning 144,000 Btu per gallon oil and operating at a seasonal efficiency of 60 per cent, if the outside design temperature for Minneapolis is --20 F, and the inside design temperature is 70 F?
Solution. From Table 6, under 60 per cent efficiency and opposite the bottom column, find the uncorrected U to be 0.00476 gal per 1000 Btu hourly heat loss.
From Table 5, the correction multiplier for --20 F outside design temperature is 0.778. Solving, 0.778 X 0.00476 = 0.00370. Making a further correction for the heating value:
0.0037 X I44 qqq = 0.0036 gal per 1000 Btu per hour calculated heat loss per degree-
day. From Table 3, the average degree-days for Minneapolis number 7883, and from the
problem N = 192. Substituting in Equation 3:
F = 0.0036 X 7883 X 192 = 5449 gal.
Table 6. Unit Fuel Consumption3 Constants for OiLb
Unit
40
Gal Oil per Sq Ft Steam Radiator.. 0.00172
Gal Oil per Sq Ft Hot Water Radiator..........
0.00108
Gal Oil per 1000 Btu per Hour Heat Loss;_________ ___ _________ 0.00715
Efficiency in Peb Cent
50
0.00137
60
0.00114
70
0.00098
0.00086 0.00072 0.00062
0^00571 0.00476 0.00409
80
0.00086 0.00054
0.00358
Based on a heating value of 140,000 Btu per gallon. Abstracted by permission from Detree-Day Handbook (Second Edition, 1937), by C. Strock and C. H, B. Hotchkiss.
Table 7. Unit Fuel Consumption3 Constants for CoALb
Unit
40
Lb Coal per Sq Ft Steam Radiator.. 0.0200
Lb Coal per Sq Ft Hot Water
Radiator
0.0125
Lb Coal per 1000 Btu per Hour Heat Loss.... .................................... 0.0825
Efficiency in Pbb Cent
50 0.0160
60 0.0133
70 0.0114
0.0100 0.0084 0.0072
0.0666 0.0550 0.0471
80
0.0100
0.0063
0.0412
Based on a heating value of 12,000 Btu per pound. ^Abstracted by permission from Detree-Day Handbook. (Second Edition, 1937). by C. Strock and C. H. B. Hotchkiss.