< Mason Leven-and-Weight P. R. V. No. 236-A
Application-- Mason No. 236-A Pressure Reducing Valve is widely employed in heating sys tems requiring accurate regulation at low pressures.
Initial pressures may be as high as 150 lbs. .
A special molded rubber dia phragm is. provided for the
All castings are heat treated to prevent distortion.
Stuffing box and valve stem are designed for minimum friction.
Lever bearing is stainless steel, pre venting corrosion and sluggish action.
Diaphragm is heavy molded rubber.
Every Mason P. R. V. No. 236-A, like all other Mason valves, is given a thorough test over its entire opera ting range before leaving the factory.
reduced pressure range of 2 to 15 lbs. A large diaphragm can be pro vided for the very delicate regulation, in ounces, of reduced pressures below 3 lbs.
Operation--
Mason P. R: V.'No. 236-A is particularly adapted for low pressure systems in which the initial pressure may at times fall below the set reduced pressure. The valve is normally open; it closes only when the reduced-pressure rises to the set limit and, working against the diaphragm, balances the weight-and-lever system.
Construction--
Main valve, valve seats, and valve body made of hard steam bronze, .machined to extremely close limits to assure permanent alignment and fit. Positive clearance.
Sizes
Sizes and Prices
736 In. Diaphragm 11 In. Diaphragm (or Reduced Pres for Reduced Pres sures 2 to 15 Lbs. sures 0 to 3 Lbs.
'h' w 1* 'w
1 'hV to 6'
>28.50 31.00 35.50 39.50 44.00 On Application
>35.50 38.00 42.50 46.50 51.00 On Application
Send for Catalogs--
For complete descriptions of Mason P. R. V. No. 236-A and other Mason re ducing and vacuum regulating valves, address the factory, or your Mason dis tributor.
810
SpecialtiesHeating
jAs. p. MARSH & COMPANY
FOUNDED IN 1865
. 2073 Southport Avenue, Chicago, 111.
551 Fifth Avenue New York. N. Y.
Branches
Bendix* Building Los Angeles, Cal.
2539 Pennsylvania Ave. Washington. D. C.
In Canada: The Jas. Morrison Brass Mfg. Co., Ltd., Toronto. Ont.
Sales Offices in Principal Cities
[> f I
4l i
i
The Company
Jas. P. Marsh & Company have been manufacturers of heating equipment and precision instruments for 66 years. These pages include brief descriptions of the Marsh System Units for installation on the heating systems noted on this page; me dium pressure specialties, gauges and in strument panels.
employed to create circulation and to withdraw air and condensate.
The Marsh Compensating Supply Con trol is placed in the supply mains. This control governs the pressure (or vacuum) and regulates the amount and temperature of the steam distributed throughout the system.
Each radiator is controlled by a Marsh .Compensating Radiator Trap. This trap
The Marsh Weather pensating System
Com-
operates to pass all water of condensate and to retain within the radiator, steam at all temperatures and pressures and to con
The Marsh
trollably limit the portion of the radiator
Weather Com pensating System of Heating is based upon well known principles. Modern
MarslL Weather Compensating System
________ ofHeating
apparatus and ap
plication of-these'principles comprise the
available-for steam by entraining the air and non-condensable gases in quantities which are varied by the pressures (vacuum) within the radiator.
The Marsh Standard Vacuum System of Heating
means of effecting absolute control of heat
The Marsh Standard Vacuum System of
output as required. (1) Temperature at Heating is a two-pipe system especially
which water boils depends entirely on-the adaptable to larger buildings. It circulates
pressure exerted uppn it. Likewise, - steam at low pressures from a boiler, central
volume of steam depends upon pressure, station or by utilizing exhaust steam.
whether from an outside source or its own generation. The amount of heat required .
Rapid circulation is secured by a mechani cally created vacuum in the return. Large
to generate steam and the consequent heat or small condensing units may be used
output of a given volume of steam varies with appropriate Marsh System Units.
with the pressure (or vacuum). (2) A-
radiator or other condensing unit can as sume steam only as the air and non condensable gases, which accumulate are purged. By controllably limiting the flow of these gases from the radiator the amount of steam entering the radiator is varied in proportion to the increase or decrease of pressure (or vacuum) in the system. The Marsh Weather Compensating System has such flexible features that the volume and
The Marsh Vapor System
The Marsh Vapor.System of Heating is a two-pipe system which rapidly circulates vapors at low pressures. In mild weather steam at a few ounces of pressure or under vacuum is sufficient to care for heat re quirements. Circulation is maintained by the Marsh System Unit Equalizer and Boiler Return Trap.
temperature of steam, delivered to the radiators are directly proportioned to cor respond with the heat demand required for prevailing weather conditions. In its construction aspects, it is similar to the two-pipe vacuum system. Steam is sup
The Marsh One-Pipe System
The Marsh System Unit Radiator Valve, together with the Marsh Air and Vacuum Valve, make the Marsh One-Pipe System ideal for small installations, eliminating
plied either by means .of a boiler or from many weaknesses heretofore inherent in
an outside source. A vacuum pump is one-pipe systems.
811