Document daD2ZYb9D2ZdvNa0xvkE7pMxb

$T0U96065 9 HE DOWTHERM SYSTEM DOWTHERM systems are very si; > .^r to ste<m> systems and are operated in much the same way. The reason for usdng E&WTtfE'RM instead of steam is that DOWTHERM boils at a much higher temperature (500F) ttyan* water (212F) and much higher temperatures can be at tained with lower system pressures than can be attained using water. Looking at the sketch "DOWTHERM A SYSTEM", the heat input to the system is accomplished in the vaporizer (DTU-3Q1)- Natural gas is burned in DTU-301 as DOWTHERM liquid is circulated through DTU-301 by pumps P-319A/B and back to D--3T9 "Flash Tank". In the flash tank, the superheated DOWTHERM vaporizes and that which does not, is recirculated through the vaporizer again. The vapor generated by the vaporizer is piped away from D-319 in vapor headers where it is controlled into various plant heaters and reboilers. Here the vapor is condensed back into liquid after giving up its heat and flows out of the heater or reboiler into a float trap. The float trap on the heat_ exchangers only allows the liquid DOWTHERM to return back into condensate headers and then into D--19 condensate tank. The liquid is collected in D-19 and pumped back into D-19C. A control valve on the inlet of D-19C controls the level of D-19 and the control valve on the outlet of D-19C controls D-3^9's level. This mak s D-19C a "floating" level tank and any changes in DOWTHERM inventory will show up ere. Controls: 7fw System Vapor prCSSOfe is controlled by s amount of heat added to the vaporizer - the gas Control valVe at DTU-301 . The pr ssure is backed up on the other end of the vapor system condensate trdpS, wh.ch only allow liquid through. con D-19 level is controlled by tffrottlin the level inlet tr >igC. 1/26/78 rw ST0496065 $70^96066 ST0496066