Document da9EkgybyBmOyv8N24ryOOo55

American Society of Heating and Ventilating Engineers Guide, 1929 connections and main risers except that the main riser will have its greatest diameter at the top. It will be seen that 35 ft. elevation will give the necessary 15 lb. pressure at the highest fixture and that the pressure drop may be made equal to the static head from the top fixtures down, or 40 lb. per 100. FRICTION IN ELBOWS Friction caused by elbows should be added to straight pipe friction. Each elbow in a line will add friction equal to a length of straight pipe forty times the diameter of the pipe: Pipe Size......... .................... H 1 Equivalent length of straight pipe in feet___. 2.5 3.3 1H 1H 2 4.1 5 6.7 8.3 3 3H 4 10 11.7 13..3 The water supply formula herewith makes it possible to accurately compute the flow of water in gallons through any pipe with any friction head and also gives formula for the additional head due to water entering the main, which, if extremely accurate calculations are necessary, should be added to the head required for friction; generally, however, this can be neglected as it is comparatively small. WATER SUPPLY FORMULA CF = cubic feet per minute discharged. G = gallons per minute discharged. H = friction head of water in feet = pressure X 2.31; if water is raised vertically, deduct number of feet raised, from head due to pressure. L = length of pipe in feet--including horizontal and vertical runs. CF - 0.16 Y X3 H L (1) v^ , o .I(3d)5 X 3 H l (2) (CF)* X L .0768 (3d)` n (G)*XL (3) 4.32 (3d)5 (4) The above formula neglects the head due to entry, which need not be computed except when L is very short. Hi = head due to entry in feet. (H, ( 0.83 G V or Hi \d* X 13/ 6.25 CF\* d* X 13/ Example.--Required the discharge of a 2 in. main with pressure 30 lb. 100 ft. hori zontal run and 30 ft. vertical run. H = 30 X 2.31 - 30 = 39.3. Formula (2) G = 1.2 J(3 *..2)` * 3 X 39 3 = 100.8 V 100 + 30 In the above case the head due to entry would be Hi /0.83 X 100.8y V2 X 2 X 13/ 2.56 ft. Usually this can be neglected except for very close calculations. 340 Chapter XX--Water Supply Systems and Piping for Buildings HOT WATER SUPPLY , Tables 7, 8, 9, 10 and 11 give the hot-water requirements for several kinds of buildings in terms of gallons per maximum hour and per day. Pipe sizes for hot-water systems may be calculated from the foregoing data on cold-water systems; using the same quantities for the gallons of hot water required per minute as is given for the cold water. It may be borne in mind that a column of hot water is lighter than one of cold water amounting to about V/% ft. per 100 ft. in the height of columns of equal weight. In cas'e the cold water must first be fed down from roof tanks to heaters in the basement and then back up to the top floor fixtures, the extra length of run must be taken into consideration. As a check on the total quantity of hot and cold water required per day it is well to know that this generally runs from 2 to 3 times the amount of hot water re quired and from 80 to 100 gal. per occupant of the building. Table 7. Hot Water Requirements for Apartment Buildings Class Lavatories Hot-Wateb Futures per Apartment Bath Tubs Showers Over Tubs Kitchen Sinks Laundry Trays Separate Showers Gallons Hot Water per Apartment per Maximum Hour Ai i i i 2 0 . 25 A2 2 i i 2 0 30 A 2 2' 2 i 2 0 35 A2 1 1 i 2 1 55 B1 .1 0 i 2 0 20 C1 1 0 i 1 0 15 Note.--The quantity of hot water required per day is usually about 10 times the maximum hour requirement. Table 8. Hot Water Requirements for Hotels Class Gallons Add fob Kitchens per Meal Capacity Add for Laundry Hot Water PerH. W. perH. W. Fixture per Fixture-per Day " Hour Per Day Per Maximum Hour Per Washer Per Piece Per Washer per per Day per Day Maximum Hour High-class transient...... Medium-class transient___ Apartment hotels__ ______ 85 70 50 6.8: 6.5 5.0 3.0 2.5 2.0 1.0 0.80 0.60 1.0 1.0 1.0 1200 1000 1000 250 200 200 Note.--Instantaneous demand rate for laundry washers from 25 to 60 gal. per minute. Table 9. Hot Water Requirements for Office Buildings Class Hot Water per Hot-Water Fixture Per Day Per Maximum Hour Having hot water in public toilets only.......... ...................... Having hot water in private offices as well as in public For self-closing hot-water fixtures deduct.--......................... 50 30 40% 5.0 3.0 25% 341