Document da0qyeLnknwVjRxYJGDb78aE0

INDUSTRIAL HYGIENE STAFF 1982 PROGRAMS PRESENTATION February 12, 1982 I.INTRODUCTION II. NOISE CONTROL PROGRAM III. VINYL CHLORIDE PROGRAM IV. INSULSPRAY V. FORMALDEHYDE MONITORING PROGRAM Norman Brusk Rick Hackman Mark Gruenwald William Hoychuk Norman Brusk BOR 005336 INTRODUCTION Borden Industrial Hygiene Evolving: A. From Fire Fighting 1. React 2. At Plant Location B. To Program Approach 1. Act 2. Systematic 3. Preventative C. Goal 1. Reduce Risk 2. Eliminate Hazards Major Programs Targeted for 1982 A. Noise Rick Hackman B. Vinyl Chloride Mark Gruenwald C. Insulspray William Hoychuk D. Formaldehyde Norm Brusk BOR 005337 III. Other Programs and Activities A. Lead B. Confined Space C. Solvents D. Ammonia E. Carbon Monoxide F. "Right to Know" G. Dermatitis/Sensitization H. Respiratory Protection I. Training J. Dichlorobenzidine K. Polyvinyl Chloride Dust BOR 005338 SECTION I NOISE CONTROL PROGRAM 1. Initial Survey 2. Hearing Protection 3. Engineering Controls Goal: Reduction of work related, premature hearing loss. SECTION II THE NEW OSHA HEARING CONSERVATION AMENDMENT requires: 1. Workplace Monitoring (by Feb. 22, 19821. 2. Provide annual audiometric testing for all employees exposed to 85 dBA (or greater) for an 8-hour average (by August 22, 1982). 3. Provide Hearing Protection for all Employees exposed to 85 dBA (or greater) for an 8-hour average. (Mandatory hearing protector use for exposures over 90 dBA for 8-hours). 4. Provide Training. BOR 005339 SECTION III BORDEN PLANTS AFFECTED Consumer Products FFOoCod Division: Division <DHaa1iry Division: 41 Plants (39 surveyed) 53 Plants (36 surveyed) Chemical Division------------------ 47 Plants (24 surveyed) International-------------------------- - 5 Plants (5 surveyed) SECTION IV THE PLAN PHASE I: 1. Information letter & questionnaire sent to plants. 2. Telephone/mail follow-up. PHASE II: 1. Review existing noise/I.H. surveys for applicable data. PHASE III :1. Evaluate and select firm(s) to provide audiometric testing. PHASE IV: 1. 2. Have audiometric testing performed. Review results. PHASE V: 1. Review of program status. 2. Follow-up surveys. 3. Follow-up audiometric testing. 4. Training BOR 005340 Sources (Measured At p*ntor/ listener distance from source) Shotgun bloat Jot plane at take-off Firecrackers, exploding Rock Music (amplified) Hockey game crowd Thunder, severe Pneumatic jackhammer Powered lawn mower Tractor, farm type Subway train (Interior) Motorcycle Snowmobile Cocktail party (100 guests) Window air-conditioner Crowded restaurant Diesel-powered truck^ractor Singing birds Normal conversation Rustle of leaves Faucet, dripping Lighl rainfall ffiSfifiM rf Haanf|a Aural Effect Human ear Pain Threshold Uncomfortably Loud Extremely Loud Moderately Loud Quiet Very Ouiet Just Audible --T wit of tome familiar sounds. Sound Level In Decibels 140 120 100 10 SO 40 10 ________O_____ BOR 005341 VINYL CHLORIDE PROGRAM INTRODUCTION A. Objective of VCM Program. B. Challenge to Industrial Hygiene Staff to insure program effectiveness. Planned activities n 1982 for VCM Program. A. Audit of Thermoplastic VCM Programs. 1. Illiopolis, IL 2. Leominster, MA B. Quantitative Fit Testing of Negative Pressure VCM Cannister Respirators. VCM Compliance Program Requirements. A. VCM Monitoring & Control B. Annual Training C. Medical Surveillance D. Signs & Labels E. Recordkeeping F. Written Compliance Program VCM Monitoring & Control System A. Objective of System - Worker Protection B. Basic Concept/Elements of System - Leak Detection and Prevention C. Mechanics of System 1. Fixed Area Monitoring & Alarm System a. Worker Responsibilities b. Support (Safety Technician) Responsibilities c. Supervisory Responsibilities BOR 005342 .2 Plant Monitoring Tours of Regulated Areas 3. Personnel Monitoring 4. Data Analysis a. Operational Errors - Work Practices b. Mechanical Errors - Engineering Controls D. System Evaluation 1. Review of Data & Records For Consistency 2. Observation of Plant Personnel In Complying With Requirements of Program 3. Determination of Frequency & Duration of Excursions and Reportable Incidents E. Summary Report To Management QUANTITATIVE FIT TESTING AT THERMOPLASTIC PLANTS A. Objective of Fit Testing VCM Cannister Respirators B. Development of Acceptable Method 1. Adaptation of High Efficiency Filter to Cannister 2. Performance Testing in Lab BOR 005343 VINYL CHLORIDE STANDARD 1910.1017 OSHA COMPLIANCE REQUIREMENTS VCM MONITORING & CONTROL PROGRAM ANNUAL TRAINING MEDICAL SURVEILLANCE SIGNS & LABELS RECORDKEEPING WRITTEN COMPLIANCE PROGRAM BOR 005344 MVC LEAK SHEET 9359 MVC LEAK LISTED BELOW WAS IMINED TO BE THE CAUSE OF HIGH S OF MVC IN THE WORKING ENVIRON' YOUR IMMEDIATE ATTENTION TO THE LEM IS REQUIRED. PPM/LOCATION DATE SHIFT TIME JMENT USED:CENTURYHNU MATE TEMPORARY REMEDY___________________________________________________ __________ ______________ ANENT REMEDY______ COMPLETEDCHECKED BY SAFETY TECH IY TECHNICIAN_____________ __________ ___ ____________ _ r FOREMAN OR GROUP LEADER ON FOR LEAK CHECK:_________ * SUPERINTENDENT _________ BOR 005345 ENGINEERING CONTROLS t MECHANICAL ERRORS RETRAINING ON WORK PRACTICES t OPERATIONAL ERRORS CORRECTIVE ACTION A PLANT MONITORING TOURS MVC LEAK SHEET tta O W o SAFETY TECH <- RESPONSE FIXED AREA MONITORING SYSTEM 1 EXCURSIONS ABOVE 1 PPM i ALARM MONITORING AFFECTED > EMPLOYEE RESPONSE PROTECTION FORMALDEHYDE TESTING INSUL5PRAY HOMES INTRODUCTION A. Objective of Presentation B. Consumer Requests for Air Testing C. Objective of Conducting Air Testing in the Home PRE-VISIT PREPARATIONS A. Homeowner Contract B. Preparation of Sampling Equipment SAMPLING PROCEDURES IN THE HOME A. Calibration B. Sample Placement C. Sampling parameters D. Collection of other Data E. Sampling Completion SAMPLE ANALYSIS A. NIOSH Chromotropic Acid Method REPORT AND RECORDKEEPING FORMAT A. Standard Report to Legal 1. Cover Letter 2. Completed Data Sheet 3. Additional Data Attachment B. Recordkeeping BOR 005347 FORMALDEHYDE MONITORING PROGRAM Background A. Statement of Policy: r 1/2 ppm Employee Exposures B. Formaldehyde Monitoring Program developed as result of several factors: 1. 1976 NIOSH Recommendations for Workplace Exposures to formaldehyde 2. Possible future Regulatory actions 3. Media attention C. The Program was established in order to: 1. Avoid "knee-jerk" reactions to any promulgation of standards. 2. Demonstrate to Borden customers that formaldehyde con trol is obtainable even under "worst-case" conditions. 3. Reduce Labor Relations effects. D. Review of the Formaldehyde Limits: 1. NIOSH 2. ACGIH 3. OSHA 4. NIOSH Recommended Standard a) More stringent then OSHA b) Provides protection against irritative effects c) Provides protection against safety hazards. E. Program Aspects: a. Exposure Limits b. Medical c. Labels & Signs d. Protective equipment e. Worker Training f. Work practices & engineering controls g. Sanitation h. Monitoring and records BOR 005348 F. A joint effort to meet the Program Requirement: 1. Plant Management 2. Chemical Division Management 3. Industrial Health Department Monitoring Program A. Premeasurement Review 1. Status Survey a. Item by Item b. Determine remaining requirements c. Schedule actions d. Follow-up 2. Sampling Locations Determinations a. Floor plan b. Where formaldehyde stored and used c. Source point d. Additionally, other areas for documentation purposes 3. Type of Monitoring Determination a. Source b. Area c. Personal Based on exposures & representative levels, area samples determined appropriate. 4. Frequence of Sampling/Sampling Times a. Purposes - trends and shifts b. Concentration c. Equipment and analytical method d. Fluctuations B. Monitoring 1. Plant Personnel are trained to: a. Set up sampling equipment b. Calibrate sampling pumps c. Correctly place the samples d. Properly handle the collected samples BOR 005349 2. Analytical Training a. Reagent preparation b. Analytical procedure c. Sample handling d. Instrumentation Calibrator e. Calculation of results 3. Sample results with raw data are sent to the Industrial Health Department for review of: a. Math errors b. Calculations c. Sample times, etc. d. Trends Plant Management and Chemical Division Managements also review the results to take corrective actions where necessary. 4. Evaluation of the program. Monitoring Results are not necessarily indicative of the effectiveness of the program. Evaluation requires "performance" criteria. a. Employee Complaints b. Health Problems c. NIOSH/OSHA Studies or Investigations 1982 Goals and Activities A. To ensure that the formaldehyde program is functioning properly and to provide renewed interest and attention to the program, annual audits are conducted at each of the plant locations. B. These locations are: Demopolis, A1 Louisville, KY Fayetteville, NC Diboll, TX Sheboygan, WI Kent, WA Fremont, CA Geismar, LA LaGrande, OR Springfield, OR Missoula, MT C. Components of the Audit: 1. Collection of air samples with those run by plant 2. Submission of prepared known samples 3. Evaluation of plant air sampling and analysis 4. Review of sampling sites Report BOR 005350