Document dYrqOq2MozEq7B47N0KJq9BpG
Monsanto Chemical Company
Anniston Method No. 14-48--13
.
flUBJECT: The Testing of Aroelors for Inorganic Chlorides
MKTHOD:
"Solutions Required
standard Chloride Solution: Dissolve 0.660 prams of pure sodium chloride in sufficient water to measure erectly 500 ml.; 1 ml. then contains 800 micrograms Cl. Pipette'25 ml. of this solution to a 500 ml. flask and make to the mark to give a 0.00115 M NaCl solution, 1 ml. of which con tains 40 raicrograms of Cl. Preserve ic a Pyrex bottie. Caution: The miter used in preparation must be chloride free by the Tyndall Beam test; the 0.00113 M solution should not be kerft over 1 month.
Silver Nitrate Solution 100: Dissolve 5 prams of silver nitrate crystals in 40 ml. of water and add 10 ml. of concentrated nitric acid.
Chloride free distilled "ater.
Apparatus Required
LaJSbtte 10 ml. color tubes (13 mm. X 100 mm).
Test tube rack with a black surface at the base for uniform comparison (Note: we are using black gasket rubber over the entire board that sup-' ports the base of test tubes during comparison.)
Box. About 7" long and 4" wide. This box contains hole3 in top and notches in the bottom to hold Lamotte color tubes. It is just high enough to allow 1/4" of test tube to extend through the holes in the top. The box should be painted a flat black on the inside and on top and should contain enough holes to accomodate at least seven tubes.
Method
Clean all flasks, tubes, and pipettes to be used. Then rinse with dilute nitric acid then with chloride free distilled water.
Add 50 ml. chloride free tvater to a 250 ml. Erlenmeyer flask, heat to boiling, add 200 gram of the Aroclor to be tested, which has been heated to 100*6, shake vigorously for 1 minute, cool in cooling pan. Carefully decant some of the water extract to a separatory funnel, flash with pure ethyl ether (chloride free).
Transfer 10 ml. of the ether washed extract to a 10 ml. Lalfotte color tube after rinsing tube with portion of extract. Prepare standards by diluting exactly 5 ml. of the 0.00133 M NaCl solution to 100 ml. in a
DSW 330886
STLCOPCB4077530
The Testing of Aroclors for Inorganic Chlorides - 2 -
volumetric flask. One ml. then contains 2 micrograras of Cl. Transfer 1, 2, and 3 ml. portions to 10 ml. tubes. lake to the 10 ml. mark with Cl free H-,0. Place standards and sample in light free box from which only the top of tubes are exposed add 0.5 ml. of the silver nitrate to each tube compare in a specially preoared test tube rack.
The comparison is to be made quickly and from a constant source of light,
preferably day light from a window away from the sunlight. Comparison
is easier when other sources of light are shielded from the comparison
rack. Look directly into the top of the tubes and compare. Note the
known solution which most nearly matches the 'ter extract estimating to
the nearest whole microgram. The extract blank and the distilled water
should show no turbidity.
.
Calculation
Divide the chloride content in micrograns of the known solution which matches the extract by the'weight of the Aroclor represented by the extract to obtain the chloride content of thg Aroclor in p.p.m.
In the procedure described, the 10 ml. extreet represents 40 grams of Aroclor (1/5 of 200 g. taken). The three knowns contain 2, 4, and 6 micrograms of Cl, thus representing 0.05, 0.10, and 0.15 p.p.m. respec tively. Values should be reported to the nearest 0.025 ppm.
Preoaut ions
Because of the sensitivity of this test, serious errors may result through very slight contamination or inattention to details. All equip ment must be scrupulously cleansed, the distilled water absolutely chloride free and testing done a\?ay from fumes of HC1 or chlorine fumes.
rs 4/27/48
DSW 330887 STLCOPCB4077531