Document dYqk1agrXLJn3nM2YGxmD92EQ
TSTftA ETHYL LEAD PLANT
June 9, I931
DR. W. . DEUEL:
A series of air samples recently taken in B Plant shows that the lead exposure encountered, remains about the same as determined by the previous test. There is but little exposure on the first floor; there is somewhat more on the fourth and fifth floors; and the still floor, as usual, constitutes the greatest hazard in the Main Building. A very little tetra ethyl lead diffuses into the smelter by the sludge pit door. The Alloy Building shows no particular change from last month.
The high results obtained at the Grinder Pan in the Alloy were caused by an unusual condition which has been obviated. A number of boles had been bored in the grinder stank in order to obtain samples of grinder exhaust gases. These holes were ade quately blocked with rubber stoppers at the termination of the tests on the mill, but in time they became unplugged, allowing a large amount of alloy dust to fly into the room during grinding. At Dr. Kehoe* s request, the air samples were taken at several levels near the stack which is beside the grinder pan. Unfortunate ly, the sampling apparatus was placed close to these holes and the very high results noted were obtained. The samplingdevice was re moved before the results were calculated and consequently investigated so that a series of check samples with the holes securely plugged could not be taken this month without undue effort and loss of time. However, the request of Br. Kehoe will be borne in mind, and the next samples taken at the grinder pan will be at different levels.
swc/icn*
J. L. STECHER, SUPT.
N9515
ANALYTICAL DATA
PlaceHeight from FloorTime of Hun
Smelter
Sludge pit door
5 ft.
24 hrs.
Alloy First floor
w? grinder
HH
Second Floor
#11 ?ot room
#12
#1'3 *
*
#11 "
11
*12
f 13 *
"
#3 grinder pan
Cooler
5"
5*
5*
^
5 * in. 6H 6* 1 ft. 3H
4
i5 "
6 in.
24 & i
24 24 it 24 it 24 Si 24 ii 24 i! 24 II 24 li 24 il 24 it 24 24 It
B Building First Floor
Air duct (by elevator) (Opposite 11)
* * (Lewis Pump)
6 In. 6 tt 6
H 11 (Opposite Lewis
Pumps)
6 (1
Lewis Pump #2 (top)
6 if
Centrifugal pump
6 tt
24 it 24 tt 24 24 it 24 tt 24 t
Third Floor Air duct (bet. 1-3)
" ( 5-7)
n ( 2-4)
( 6-S)
Fourth Floor
#7 front ;fg
$9 " #10
Fifth Floor
Air Duct (bet.1-3)
"" B
( H 3-5) ( . 5-7)
6H 6 tt 6 tt 6 '*
6 6 tt 6 tt 6 tt
6 ff 6 It 6K
24 tt 24 tt 24 tt 24 it
24 tt 24 if 24 tt 24 tt
24 tt 24 tt
24*
Pb as Mg/eu.ft.
.0059
.0059 Kg
.0019 Bg .0059
m
.0019 .0004 .09S .250 .0059
Kg
.0019
Kg , .0004
Kg tt
.0019 Mg
Met .0040 .0059 .0059
.0019 .0019
Ng n
____ .OUU*f .0019 Kg !
ftAI i
N9515.01