Document dYm3VVjqVbOw141JK19Kg5rEe

HONS 0 7 1 5 4 1 7V S T 10 SNOW | | | : i \ 1 j j ' *. ' , *** .......................... has been used successfully since 1941 as a liquid phase heat transfer medium at atmospheric pressure and temperatures up to 600F. The compound, essentially tetrachlorobiphenyl, is a fire-resistant and noncorrosive liquid, which does not crystallize at low temperatures. Handled properly, in well-designed forced circulation heat exchangers which avoid localized over heating damage, the fluid gives satisfactory continuous service for many years without replacement. Most significant, Aroclor 1248 is practically non-flammable. In one installation of record, arupturedpipe spewed thehot fluid into gas flames: the fluid failed to ignite! For general heat transfer, Aroclor 1248 has several other important qualities: it is highly mobile and can be readily pumped at temperatures as low as 50*F. If cooling is necessary, the heat transfer fluid can be put through a water cooler to be used as a coolant.. . using this single fluid for both heating and cooling. Aroclor 1248 transfers heat (up to 600'F.) as a liquid. This liquid phase heat transfer makes it unnecessary to use the expensive pressurized equipment required by a heat transfer medium that operates as a vapor. Aroclor 1248 operates safely and efficiently with gas-fired, oil-fired, or electrical heat sources. It is used successfully in the following types of applications .... l i i i 1 i - 4i Chemical Processing Equipment, particularly for reacting flammable materials Cooking of Alkyd resins, varnishes, waxes Plastics molding, extruding, calendering Rubber processing Heating asphalt J Food Processing, including potato chip and doughnut frying in vegetable oils \ \ Processing titanium,' magnesium, other non*ferrous metals \ Fabrication of magnesium and aluminum honey*comb structures for aircraft Indirect heating in dyestuff manufacture Heating of corrugating rolls 1 Indirect heating of distillation equipment j Saponification of hits SNOW Calcining Ovens Impregnation and lamination of fibrous materials TABLE Appearance Absolute density, g./ml. Absolute viscosity, centipoises Thermal Conductivity, Btu./hr./sq. ft/*F./ft Spec. Volume, ml./g. Practically colorless mobile liquid. Temperature "Centigrade "Fahrenheit 1.44 30 86 1.41 60 140 1.37 100 212 1.27 200 392 1.17 300 . 572 112.0 30 86 17.5 60 140 4.2 100 212 0.99 200 392 0.47 300 572 0.0571 30 0.0564 60 0.0555 100 0.0534* 200 0.0512* 300 'Extrapolated Data 86 140 212 392 572 0.696 0.709 0.728 0.787 0.860 30 60 100 200 300 86 140 212 392 572 reVSTEO SNOW CONTINUED HONS 0 7 1 5 4 5 (Tibit 1, cont.) Spec. Heat, cal./g./C. Vapor Pressure, mm. Hg. Distillation Range, ASTM D-20 Rash Pt., Cleveland Open Cup, ASTM D 92-45 Fire Pt., Cleveland Open Cup, ASTM, D 92 45 Pour Pt, ASTM, D-97 Average Coefficient of Expansion cc./cc./F. 0.283 0.297 0.326 0.355 0.00037 0.16 2.9 18.0 350.0 `Centigrade 50 100 200 300 `Fahrenheit 122 212 392 572 37.8 100 150 200 300 100 212 302 392 572 345-385 652-725 193-196 379-384 None 0.00037 0.00038 0.00041 000044 000047 0.00052 -7 -17.8 to 37.8 37.8 to 93.3 93.3 to 149 149 to 204 204 to 260 260 to 316 19.4 OtolOO 100 to 200 200 Id 300 300 to 400 400 to 500 500 Id 600 PHYSICAL CHARACTERISTICS of AROCLOR 1248 A complete knowledge of the physical characteristics of heat transfer media is highly essential to their satisfactory application in a heat exchanger. These physical constants have a major hearing on the equipment design, its mainte nance, and its operation. The following figures and charts give basic physical data on Aroclor 1248. DENSITY OF AROCLOR 1248 (Tp an, b7c. ft; fcnH-- xk, gmJmL) 92 90 SI 16 DCNSITY IK/ol ft. 84 82 B 78 78 74 72 VISCOSITT OF AROCLOR 1248 Figun t e MGNS 0 7 1 5 4 7 VISCOSITY OF AROCLOR 1248 (Scybelt Um*omI Seconds) VISCOSITY, SAYBOIT UNIVERSAL SECONDS HONS 0 7 1 5 4 8 Fifwo 3 TEMraUTlWC. 0C6KCS fAHKHNCIT 7 HEAT CAPACITY and Its Relationship to Density Systematic errors exist in the various accepted pro cedures for making specific heat determinations. Consequently values may vary depending upon the procedure used. In practical operation, it frequently appears that the values for Aroclor 1248 shown in Figure 4 are somewhat low. Consequently, although these values have been accurately determined, they may be regarded as conservative. When comparing the specific heat values of Aroclor 1248 with corresponding values for other heat transfer fluids, it is important to note that the density of Aroclor 1248 is much higher, relatively, than the deasity of other liquids used for heat transfer. Accord ingly, when comparison of heat capacity is made on a volume basis (which is most pertinent in equipment design and efficient operation) the heat capacity of Aroclor 1248 shows itself to better advantage than by direct comparison of specific heat values. Although specific heat values are important, they represent only one of several important constants that enter into the equations for calculating over-all heat transfer efficiency. Through the use of these conservative heat capacity values, it is possible that equipment engi neered from such data might l>e slightly "over designed.* This may he one of the factors that accounts for the exceptionally good operating performance of a number of highly successful commercial applications. SPECIFIC HEAT OF AROCLOR 1248 (Bto. per lb. per 6epee F.) T! TEMPERATURE * f . X o z C/> oo ui o Figure 4 SPECIFIC MEAT 9 Temperature C. #F. 0 32 10 50 38 100 66 150 93 200 121 250 149 300 177 350 204 400 232 450 260 500 288 550 316 600 TABLE II HEAT CONTENT of Aroclor 1248 Specific Heat , Btu./lb./'F, .269 .272 .280 :" .288 .295 .303 Jll .319 .327 .335 .343 .351 .359 Heat Content Btu./lb. 0.0 4.85 18.65 32.85 47.43 62.38 77.58 93.48 109.66 ' 126.21 143.17 160.52 178.27 TSST*0 10 THERMAL CONDUCTIVITY and VISCOSITY The thermal conductivity values of Aroclor 1248 are shown in Figure 5. The curve shows this value over the operating temperature range, from 5fTF. tofiOCFF., of Aroclwr 1248. As freshly charged into a heat exchanger, Aroclor 1248 has an initial viscosity of 74 (S.U.S.) at 1303F. which corresponds to a viscosity of approxi mately 5000 (S.U.S.) at 50F. -- which temperature is assumed for practical purposes to be about the limit at which Aroclor 1248 can he conveniently pumped with a centrifugal pump. The following table shows a comparison of the initial viscosity and the viscosity after a years con tinuous service at 600F. in a LaMont forced circu lation heater: TABLE HI Mpenoci SfMbfic Gravity, 65* C. Viscosity. S. U. at HOf. OrifiMl Cotartsss liquid 1.410 74.0 After on* Year of service at ttO*F. Oark Brow* liquid 1.411 0.5 Although Aroclor 1248 tends to darken in rise, this darkening is not harmful and does not indicate decomposition. In actual use at Monsanto, it has not been found necessary to replace the fluid after seven years of continuous use; additional fluid is only added as necessary to make up spill$ or leaks. In Figure 6, the horizontal line indicating vis cosity limit of pumpability at 50F. shows that the rate of viscosity increase based on a year's continuous service should permit Aroclor 1248 to serve approxi mately four years before increased viscosity may inter fere with its pumpability when cold. In practice, Aroclor 1248 has given satisfactory pumpability for much longer periods. A simple S.U.S. viscosity deter mination by the ASTM-D-88 method can be used for periodic checks on the fluid. THERMAL CONDUCTIVITY OF AROCLOR 1248 (Dotted titmiiio ndiotts utinwlrtnl data) EXPECTED MINIMUM SERVICE LIFE IN A FORCED CIRCULATION HEATER VISCOSITY, SAYBOIT SECONDS, at 1 3 0 T HONS 0 7 1 5 5 ^ Fipnw YlMSOMBCATttrr. 13 STABILITY Avoclor 1248 is an extremely stable chemical com pound. Tests over long periods of time have shown that 600F. is a safe maximum temperature for continuous operation in heaters that are properly designed and operated to eliminate intense, localized overheating. At this temperature the fluid is 52F. below the initial temperature of its boiling range, and consequently re mains a liquid. Near its boiling point Aroclor 1248 tends to dehydrohalogenate to a very slight but measurable degree. If this occurs as a result of accidental over heating. the small amount of HC1 gas evolved tends to pass through the vent tank without harm to the equipment provided that the system is dry. Experimental observations using ideally-suited heat exchangers operating at a temperature of 650F. with imposed nitrogen pressures of 30 and 70 psig. showed that application of pressure did not prevent this small amount of thermal decomposition, which also occurs when the material is heated above 600eF. at atmospheric pressure. When heated continuously at 650F. under nitrogen pressure a gradual increase in the viscosity of the fluid occurs indicating that its service life would be limited to about 6 months to one year. Hestdls of operating at 600F., however, with out imposed nitrogen pressure indicate Aroclor 1248 can be heated continuously at this temperature for about 4 years before any viscosity increase could be expected to interfere with its pmnpability at 50F. which is slightly lielow normal room temperatures. Provision should lie made to prevent water contamination of the system. If the system becomes contaminated with water, any HC1 liberated by local ized overheating may dissolve in the water film which will float on top of Aroclor 1248 in the expansion tank. The acidic solution thus formed can cause corrosion. It is recommended that moisture be eliminated from the expansion tank by installing a moisture trap or by sealing the tank and applying 15 to 30 psig. of nitrogen gas. With exception of the expansion tank, the system should be kept full of Aroclor 1248 at all times to pre vent formation of air pockets where moisture may condense when the system cools off between periods of operation. Many yean of practical operating experience have shown that Aroclor 1248 is virtually non-corrosive to valves, piping, tanks, and jackets made of cast steel, steel, or stainless steel. In actual use, brass valves have been used satisfactorily. t HONS 0 7 1 5 5 5 H SAFETY of OPERATION Aroclor 12-18 can he considered a non-flammable liquid; no fire point is obtained by the Cleveland Open Cup method on heating to its boiling point (650F.). The spontaneous ignition temperature*2* is 1,299F. In actual use, the following rejxjrtcd accident in a heating system demonstrates the fire resistance of Aroclor 1248 and the freedom it offers from the hazard of fire projMgation. An operator's failure to start the circulation pump when the gas heater was on resulted in excessive coil temperatures. The line containing Aroclor 1248 sagged into the fire chamber. A weld rup tured and Aroclor 1248 poured into the red-hot fire chamber in contact with the flame. Dense smoke and fumes arose from the heater but there was no external fire. After the gas flame was cut off, the smoking stopped. Insurance authorities allow the use of Aroclor 1248 heaters in many locations with a minimum of protection. No fire walls are required to isolate the heaters. Aroclor 1248 has a low vapor pressure. In sys tems that employ a vented expansion tank, the loss due to evaporation is not measurable. If Aroclor 1248 in the expansion tank would reach a temperature of 2665F., the vapor pressure of the fluid would be only 1 mm. of Ilg. SAFETY OF HANDLING Aroclor 1248 is an inert, unrcactivc liquid. If it is spilled on the skin, there are no noticeable ill effects. It is advisable, however, to wash the skin with soap and water after contact. A skin burn resulting from accidental contact with hot Aroclor 1248 should be treated in the norma! manner for hot oil bums. Any liquid adhering to the burned area need not be removed immediately unless treatment of the bum demands it. If the burn must be cleaned, soap and water or repeated washings with a vegetable oil (olive oil) may he used. The vapors emitted by Aroclor 1248 heated to elevated temperatures are injurious on prolonged ex posure and should not be breathed. It is indicated that 2.0 mg. of Aroclor 1248 per cubic meter of air is the maximum safe amount permissahie in workrooms. In commercial heat transfer installations, it is presumed that Aroclor 1248 will be used in a closed system free from leaks. Accordingly, there should be little or no opportunity for workers to come in contact with Aroclor 1248 vapors. A bibliography appears on page 12. HONS 0 7 1 5 5 6 I i [ HEATER The most significant factor to remember when selecting or de signing a heat exchanger for Aroclor 1248 use is this: Aroclor 1248 transfers heat while in liquid form, at the maximum recommended temperature of 600F. for continuous operation, which is approximately 50'F. below the boiling point. Conse quently, Aroclor 1248 does not form vapor to accelerate convection circulation. Ordinary fire-tube or water-tube heaters which depend solely upon convection perform satisfactorily only at relatively k>w temperatures. When temperatures of 500-600F. are required, a forced circu lation type licater is recommended. A satisfactory type of heater design would consist of a specified number of tubes in parallel, properly orificed to (>rovide a high velocity fluid flow of 8 to 10 feet per second. These should be spaced to permit uniform heat absorption throughout their entire length. A typical construction is shown in Figure 7. In its fabrication, the heater should be ASME Code all-welded construction, conforming to state and local ordinances. Tube joints, which in an ordinary steam heater would be the expanded type, must be sealwelded to prevent leakage. All connections largeT than V' should be flanged connections, since ordinary threaded pipe connection is not suited for Aroclor 1248 service. Spiral-wound stainless steel and asbestos com bination is recommended for sealing joints and plugs. Drain valves should be installed at all low points on the heater and the valves must conform with ASME requirements for"blow down'* valves. I HONS 0 7 1 5 5 7 I Since a heater operating on Amclor 1248 is completely filled with liquid, costly liquid-level controls and condensate return pipes, fittings, traps, etc, are completely eliminated. Heaters can be provided with any desired kind of firing. Portable and small size stationary units are frequently elec trically heated; larger units may be gas- or oil-fired. In installa tions where an open game presents a lire hazard, to meet insurance requirements the heater may be installed in a sepa rate building with piping carrying the hot Arodor 1248 to the point of use. Properly constructed transmission pipes may ex tend for hundreds of feet. HEATER EFFICIENCY Forced circulation heaters with integral economizers will show an efficiency of from 75 to 80*. Heaters of the straight con nector type show efficiencies of 85 to 75*. depending upon the discharge temperatures. HEATER CAPACITIES ' Heaters using Arodor 1248 (gas- or oil-fired) are available in output capacities ranging from approximately 250,000 Btu. per hour to large units rated over 10 million Btu. per hour. A heat flux density (or heat energy input) of approximately 5,000 Btu. per hour per square foot of tube surface is regarded as satisfactory. For lower output rate, electrically-heated units are favored, employing watt densities of 12 to 16 watts per square inch of element area. HONS 0 7 1 5 5 8 17 MCNS 07X559 THE USERS The "users* or recipients of (lie heat at the point of processing can he any tyj*c of heating pan, platen, jacketed kettle, or coils of steel or stainless steel construction. Ordinary low pressure conilmdion is satisfactory, since the pressure imposed on tlc Aroclur 1248 seldom cscccds 50 psig. In (he u>cr. however, it is important llmt all-welded construction lie used. Threaded connections may allow leakage of the hot fluid. As in the heater, all connections *.\m and over should he flanged and aII joints sealed with spiral wound stainless steel and asbestos gasket material. Alloy holts should he used to secure flanges. A typical system with several users is shown in Figure 8. 18 (xpuvon nua lull urn uucc OXD SUIT Figure 8 THE PUMP For most systems, cast-steel centrifugal pumps with watercooled stuffing box and l>carings arc to be prefened. However, high temperature centrifugal pumjw with mechanical seals are now available which give excellent performance. In some installatious, immersion pumps have lx*en used. Whatever type is selected, the pump capacity and pressure head must be sufficient to circulate the volume of fluid at the rate the particular installation demands. To avoid shaft trouble and leakage at the seals, it is important to provide adequate expansion joints and to support the piping in a manner to avoid stresses on the body of the pump. Direct-connection pumps driven by 1,750 rpm. motors are most commonly used. Each pump should l>e fitted with a positive differential control to switch off the burner in case of pump failure. When a new system is first put into operation, a slight leakage may be noticed at the pump. It is not advisable to tighten the pump gland, however, until the system has heated up close to the temperature of operation. PIPING LAYOUT The most important factors in Hie piping layout for Aroclor 1248 systems are (a) proper sizing for the required flow rate and (b) minimizing pressure drop. Because the sys tem will undergo temperature dranges, adequate expansion joints and loops to relieve expansion and contraction stress are essential. All pipe lines and connections should be of extra heavy or Schedule 80 welded construction meeting A.S.M.E. require ments. Flanged joints should be used as sparingly as possible to minimize potential leak points. All valves and controls should le cast steel construction with stainless steel scats. Pipe lines should Ik* well insulated and those exposed to temperatures l>clow 70F. should be steam jacketed. All high points in the piping system should l>e provided with vent valves; ail low points should have drain connections. Piping should Ik* well anchored at frequent intervals, particu larly near ex]>aiisioi) loops, to prevent vibrations. Figure 9 shows a typical piping diagram that illustrates the important features of an Aroclor 1248 piping system. These may lie varied to suit the installation. HONS C7 1 5 6 0 + THE EXPANSION TANK The expansion tank should lie large enough to accom modate al>out 20% of the total volume of the entire system, including the fluid content of the heater, piping, and all heatusers. Tank should he sized to be %-full when system is cooled to TO^F. and %-full when system is at maximum operating tem perature. Expansion tank should he fitted with a sight glass at tlie "fiilF range and a float-ojicrated low-level switch to shut off burner in case of accidental fluid loss in the system. The expansion tank should be mounted on a platform high enough to support the liquid reservoir at least six feet higher than the highest point in the piping system. THE FEED and DRAIN PUMP To eliminate manual filling and draining of the heating system, it is recommended that a small 2-to-5 gpm. positive displacement pump be installed at some convenient point to pump the Aroclor 1248 into or out of the system. CONTROLS Controls for heating systems using Aroclor 1248 should be installed both on the heater itself and on the heat-using units. A wide variety of thermo-operating controls are available and any reliable standard equipment is satisfactory. Heater controls should be installed to regulate the firing mechanism in direct proportion to the required output. These controls should increase or decrease the heat in-put to main* tain the Aroclor 1248 at the operating temperature required by t)c heat-demand of the user. Small units may be operated satisfactorily by relatively simple "on-off* or "high-low" con trollers, larger units may operate more uniformly if equipped with modulating temperature controls. User Controls should be installed to regulate the flow of the heat transfer fluid in direct proportion to the heat-con sumption of die heat-using equipment. In a multiple-user sys tem, separate controls should be installed on each consuming unit, to assure the proper heat-delivery. Safety Controls. In addition to activating controls, the heater must also be fitted with the proper safety controls to meet the indude: A.S.M.E. requirements. Safely controls should 1. A high tjm|XTulurc limit control operating at tl*c heater outlet to shut off tlie burner in the event of an excessive temperature rise. 2. A suitable low-limit temperature control to hold the burner at low fire until the Aroclor 1248 in the system readies a temperature level of 180*F. The low limit temperature control is essential because the viscosity of Aroclor 1248 is rather high at normal room tem perature. To avoid localized overheating upon start-up, it is not advisable to apply full heat from the burner until all the fluid in the system Ins attained a viscosity that allows good flow and unimpeded circulation. Cold start-ups require slow up-hcats. Burners should be equipped with automatic ignition controls and flame failure controls. In wide-range firing opera tions, an over-fire draft control will increase the economy of operation. Induced draft fans are another factor which should be considered as a means of avoiding the expense of high chimneys. Where they are needed throughout the system, good quality recording or indicating gauges should be installed. COOLING EQUIPMENT Where fast reduction of temperature is required, suitable air- or water-cooling installations may be used, if the cooler is to be a water-type unit, it is suggested that stainless steel tubing be used for the coils to avoid corrosion on the water side. If a cooler is installed in the system, low temperature limit con trols should also be installed to avoid excessive cooling that might raise the viscosity to the point of impeding the circulation in the system. HONS 0 7 1 5 6 1 20 MOMS 0 7 1 5 6 2 FILTERING EQUIPMENT When heating systems operated on Aioclor 1248 are ran continuously near the recommended maximum temperature of operation (GOO^F), it is advisable to provide a filtering device that can he attached to the drain line of the storage tank. In this way discrete particles of dirt that may get into the system can be filtered out periodically. This is an advisable maintenance step since it will eliminate the danger of dirt clogging the valve seats or lodging in parts of the control mechanisms- A small portable filter such as those manufactured by Honan-Crane Corporation (Lebanon, Ind.) or Sparkler Manufac turing Company (Mundelein, III.) is quite satisfactory. CONNECTIONS and GASKETS In a system operated on Aroclor 1248, welded connec tions are preferable; threaded screw connections should he avoided wherever possible. This precaution will minimize leaks with consequent make-up. AH connections V and over should be of the flanged type fastened with alloy l>olts to prevent frozen connections. Steel connectors should be used for all instruments and controls. For gasketing, spiral wound gaskets of corrugated stainless steel and asbestos combination should be used on all flanged connections. TESTING and CLEANING THE SYSTEM When a new system has been installed, it is essential to test the entire system hydrostatically for leaks, and to wash out all the lines to remove dirt, oil films, or pipe scale. Both the cleaning and the testing can be done in a single operation as follows: Fill the entire system with a water solution containing 5 pounds of soda ash and 5 pounds of caustic soda for every 1000 pounds (120 gal) of water used. Thoroughly vent the sys tem at all of the highest points in the piping system to assure complete filling . . . then start the circulating pump. With the pump running, the entire system is next inspected for leaks. Next, turn on the burner at low-fire rate and raise the temperature of the wash solution to 180" F. This hot wash solu tion should he circulated continuously through the entire system (heater and all users) for at least 24 hours- At regular intervals a portion of the solution should be drained and replaced by fresh water. This partial draining should l>e continued at regular in tervals until the drainage from the system is clear. At the end of the 24 hour period, the temperature of the circulating wash solution should lx* brought up to 240F. and the fire turned off. The whole system should then lx; drained and all vents in the piping opened. Residual heat will dry the pipes and the heater through the vents, which should remain open until inspection shows that the system is entirely dry. When all traces of water have dried out, the drains and vents are dosed. Aroclor 1248 is then charged into the cleaned, dry sys tem. The circulating pomp is started and firing begun at low heat until the Aroclor 1248 has reached a temperature of 250F. Periodically during tins initial np-hcating, the lines should be vented every 10-18 minutes for at least two hours to allow any residual moisture or air to escape. After it is certain that all moisture has been eliminated from tlie system, the entire system should he inspected for leaks with the pump circulating the hot fluid. As a final inspection, the expansion tank should be checked to make sure that the tank is Mi full. After this, the burner can be set to full-fire and the system brought up to operating tem perature. Wlien the temperature of operation has been reached all controls should be checked and adjusted so that the burner is regulated for full modulation. When the system is brought to full operating temperature, aQ pipe lines should be given a final inspection for expansion and bracing. GENERAL RECOMMENDATIONS for Operation and Maintenance The following recommendations are primarily guides for the manner of using Aroclor 1248 in an operating system. They are supplemental to the equipment manufacturers own recommendations for operation and maintenance that relate to the heaters or the heat-using installations themselves. The recommendations for start-up, shut-down, precautions in event of power failure, and periodic check-ups on the fluid and equip ment apply as generally accepted practice on all types and sizes of systems. By following these recommendations, tle troublefree service life of the heat transfer fluid will be increased. START-UP When systems have been shut down for week-ends or over-night and the fluid is cooled t6 room temperature, follow this start-up procedure: 1. Start the circulating pump and check the expansion tank to nuke certain the Arodor 1248 is at the proper cold-start level (Tank should be ft-full.) 2. Start burner at minimum flame setting and continue full circulation until Aroclor 1348 is heated to ]80aF. .whrn measured on the return side of the heater. * 3. Tom heater up to full heat. SHUT-DOWN The following procedure will eliminate overheating of the fluid when shutting down: 1. Shut off burner completely with circulating pump still oper ating. Contintie to run the circulating rump at full head for at least ft hour to dissipate high residual heat in the com bustion chamber of the 1Turner. 2. Shut off circulating punip at the end of ft hour and switch off all heater electrical controls. PRECAUTIONS IN COLD WEATHER When heat exchanger is exposed to ambient tempera tures below 503F., it is recommended that unit not be shut down. It is recommended that the burner he turned low and the fluid circulated continuously at alxrnt 2009F. The unit will then be "at ready* for immediate high temperature operation. PRECAUTIONS IN CASE OF POWER FAILURE In case of power failure, the burner circuit is interrupted by the heater controls. When power comes on, the circulating pump should first 1)C run for a few minutes to eliminate any vapor pockets that might have been formed by the fluids being held static in the hot combustion chamber. If there is no knock ing in the piping system, full-fire may be resumed immediately, if the fluid temperature is al>ove 180^. PERIODIC CHECK-UPS The regular maintenance inspection schedule should include the equipment manufacturer s recommendations and also inspection of the heat transfer fluid. The following is a listing of check points. 1. Lulwivation of moving partv. 2. Operating fidelity and accuracy of readings of safety controls arid temperature limit controls. 3. Inspection of heater tidies, Imrner, refractory linings. 4. Periodic cEaning of licatcr surfaces. 5. Inspection of water cooling at tin* circulating pump. 6. Regular repacking of stuffing Iw* according to tl*c manu facturer's n*cnnmM*ndali(nu. 7. .Semi-annual or niumal sampling and analysis of Amdor 1248. Uitdcr normal 0[*:ruting conditions not affected by fre quent power failures or accidental overheating, when Aroclor 1248 is operated at 000F. it should not lx* necessary to clteck on the condition of the fluid more often than once or twice a year. TI)c analysis for fluid condition is a simple determina tion of viscosity. The information given in Figure 6 serves as a guide to estimate the condition of the fluid, according to vis cosity values. Most users do their own testing; some have the viscosity determination made by an outside laboratory. Customers can have their fluid tested by Monsanto free of charge. A one-quart sample is required, and sample should be carefully packed to avoid breakage in shipment Samples should be shipped to: Monigo Chemical Company Oimk Chemicals DMnm Industrial Fluid Salas St Louis, Missouri AtOVE INFORMATION APPEARS ON POCKET CARDS INSIDE RACK COVER MCNS 0 7 1 5 6 3 22 t Designing or purchasing equipment for a heating system to be operated with Aroclor as a medium to deliver heat into a process requires consideration of heat transfer characteristics of both the user and the heater. The actual heat which can be absorbed by a user, for example, depends upon the over-all heat transfer coefficient, heat transfer area, and a mean tem perature difference between Aroclor and the material being heated, both overall heat transfer coefficient and mean temperature difference are, in turn, affected by the flow rate of the Aroclor. This inter-relation of flow rate, heat, and temperature is usually solved by a trial and error procedure as covered in standard reference texts. The approach of Cranctf1) may be used to minimize or eliminate trial and error. The following tables and graphs of physical properties and engi neering data arc provided as an aid in layout and design calculations for systems to be operated with Aroclor 1248 as a heat transfer fluid in the liquid phase. Table IV lists properties useful in heat balance calculations by which the flow rate is related to the heat transferred and the temperature change of the Aroclor. This relation is also shown graphically in Figure 10. The over-all heat transfer coefficient for the heater or user may be estimated by the methods outlined in the texts of McAdams^) or Kern(5). This is usually done by combining the individual film coefficient of the Aroclor with other coefficients and conductivities to yield the over-all coefficient. Table V contains physical properties of Aroclor as a function of temperature which are needed for calculating the Aroclor film coefficient. Table VI gives typical film coefficients for Aroclor flowing through a 0.81 inch j.d. tube. These are listed as a function of temperature and flow rate in a tubular heat exchanger. Other tube sizes would, of course, require a correction for the diameter in the Reynolds and Nusselt group of the equation (from McAdams) given at the top of Table VI. Correlations for estimating film coefficients for various materials that might be processed by indirectbeating may be found in the texts cited (4). (*) and elsewhere in the literature. For sizing pipe lines and pumping requirements. Figure 11 shows pressure drop vs. flow rate and pipe size for Aroclor 1248 at temperatures over 300F. Above this temperature Aroclor 1248 flows freely like water. A hihbopaiihy ippewi am page 32. U HONS 0 7 1 5 6 4 J J TABLE IV ( ( THERMODYNAMIC PROPERTIES OF AR0C10R 1241 Timpmtur* f. c. 32 0 40 4 SO 10 0 16 /O 21 80 27 90 32 noi(KJ 38 43 1?0 49 130 54 140 60 ISO 66 160 71 1/0 77 180 82 190 88 200 93 210 99 ??0 104 230 110 240 116 7S0 121 260 127 270 132 280 138 290 143 300 149 310 154 320 160 330 166 340 171 3S0 177 360 182 3/0 188 380 193 390 199 400 204 410 210 420 216 430 221 440 227 4*0 232 460 238 420 243 480 249 490 254 500 260 *10 266 *20 271 530 277 540 282 SbO 288 560 293 5/0 299 *80 304 *90 310 600 326 610 321 620 327 630 332 tntlulpy aiu./*. 0.000 2.162 4.881 7.616 10.367 13.134 15.917 18.716 21.531 24.362 27.209 30.072 32.9*1 35.846 38.757 41.784 44.727 47.686 50.661 53.651 56.657 59.679 62.717 65.771 68.841 71.927 74.029 77.147 80.281 83.431 86.597 89.779 92.977 96.191 99.421 102.667 105.929 109.206 112.499 115.808 119.133 122.474 12S.831 129.204 132.593 135.998 139.419 142.856 146.309 149.778 153.262 156.762 160.278 163.810 167.358 170.922 174.502 178.098 181.710 185.338 188.982 Cp (Spw. HmO 0.2695 0.2711 0.2727 0.2743 0.2759 0.2775 0.279] 0.2107 0.2823 0.2839 0.2855 0.2871 0.2887 0.2903 0.2919 0.2935 0.2951 0.2967 0.2982 0.2998 0.3014 0.3030 0.3046 0.3062 0.3078 0.3094 0.3110 0.3128 0.3142 0.3158 0.3174 0.3190 0.3206 0.3222 03238 0.3254 0.3269 0.3289 0.3301 0.3317 0.3331 0.3349 0.3365 0.3381 0.3397 0.3413 0.3429 0.3445 0.3461 0.3476 0.3492 0.3508 0.3524 0.3540 0.3556 0.3572 0.3581 0.3604 0.3620 0.3636 0.3652 tMlNp Ikt/OLft. 91.6 91.3 90.9 90.8 907 89.8 89.5 89.1 88.1 881 87.8 87.4 97.9 86.8 86.2 85.9 85.6 85.2 84.8 84.4 84.1 83.7 83.4 831 82.9 12.6 823 81.9 81.6 812 10.9 80.6 802 79.8 79.4 79.1 78.8 78.5 78.2 77.9 77.6 77.2 76.6 76.4 76.1 75.7 75.4 750 74.7 74.4 74.1 73.7 73.4 73.0 72.7 72.4 72.0 71.7 71.4 710 12.22 12.19 12.13 12.08 12.03 12.00 11.96 U.9I 11.87 11.82 11.77 11.73 11.69 11.64 11.58 11.53 11.47 11.42 11.31 11.34 11.29 11.24 11.11 11.14 11.10 11.06 11.03 10.96 10.94 10.90 10.85 10.8! 10.76 10.71 10.67 10.62 10.57 10.53 10.41 10.43 10.39 10.34 10.30 10.2S 10.20 10.16 1011 IQ.Q6 10.02 9.91 9.94 9.90 9.85 9.80 9.76 9.71 9.67 9.63 9.58 953 9.48 1.47 1.46 1.455 1.45 1.445 1.40 1.432 1.425 1.420 1.414 1.409 1404 1.400 1.493 1.387 1.381 1.375 1.370 1.365 1.359 1.353 1.348 1342 1.336 1331 1326 1.321 1.316 1.311 1.305 1.300 1.296 1.291 1.286 1.2M 1.274 1.269 1264 1.259 1.253 1.241 1.243 1.237 1231 1225 1.220 1.214 1.203 1.202 1.196 1.191 1.186 1.180 1175 1.170 1-165 Utt I.ISS 1150 1144 1.131 CoMfcMm 850 380 200 115 61 47 32 26 16 14 11 9.1 7.5 U 5J 4.4 3.9 3.35 3.00 2.68 2.38 2.00 196 1.82 1.68 1.50 1.46 142 1.30 1.22 113 1.10 1.05 1.00 0.96 Q.9t 0.07 0.84 0.80 0.76 0.73 0.71 .061 0.65 0.61 060 057 0.SS 0.S3 0.51 0.49 0.47 0.45 0.13 0.42 0.40 039 0.37 MONS 071565 FLOW RATES FOR AROCLOR 1248 U TEMPERATURE DIFFERENTIAL *F OF AROCLOR ENTERING AND LEAVING THE USER MUNS 0 7 1 5 6 6 sfiJIsa g g S S S silS S iiise S S S sg ssg ssK i T--fintari C 0 4 10 26 a 27 32 38 43 49 54 a 66 71 77 82 a 93 91 104 111 116 122 127 132 138 143 149 154 TABLE V THERMODYNAMIC PROPERTIES of AROCLOR 1248 PRAKOTl k a4m* VqcMr lb IMnuf CwftKtiirty *< ivr Nr. ft. R. Hr. f. k L*J TMsnkn *F. t. AMM* Vitcwt; LkS- (wficlirihl Ota. 2060 960 485 278 160 114 77.5 58.0 43.5 33.8 21.6 22.0 18.2 153 12.6 10.6 9.45 t-10 lit 6a 5.76 5.03 4.75 4.41 4317 U3 00577 31576 0.575 3)574 31573 31572 31570 31569 31568 31566 3)565 31564 0563 4562 4560 4559 .0551 .0557 4555 4554 4553 4552 4550 4549 .05a 4547 4546 4544 4543 9844 4430 2353 1361 789 566 388 293 221 173 137 US 95 S 67 57 51.1 44.1 394 35.9 32.1 284 218 211 23.4 224 39.5 28.7 221 17.9 14.4 12.6 10.8 9.7 1? : 7.81 7.15 161 118 171 138 5.05 4.83 4.55 436 4.18 4.00 3.81 3.73 3.(3 341 3.45 - 320 160 330 166 340 171 350 177 360 182 370 188 380 193 390 IS 400 204 410 210 42Q 216 430 221 440 227 450 232 460 238 470 243 480 249 490 254 500 260 510 266 520 271 530 277 540 282 550 288 560 293 570 299 580 304 SO 310 so 316 3.53 .0542 3.34 .0541 3.14 .0540 2.95 .0539 2.78 .0537 266 .0536 254 .0535 142 3534 2.32 .0532 2.20 .0531 210 5530 2.03 .0529 193 .0527 1.83 41526 1.76 .0525 1.71 .0524 1.64 41523 157 4)521 151 4)521 1.45 41519 138 4)518 133 4)516 138 4)515 132 4)514 M8 41513 1.13 4)512 139 .0510 1J4 4809 1J1 -0500 Ct* k 206 19.6 18.S 17.5 16.7 16.1 15.4 14.8 143 13.7 13.1 12.7 123 11.7 113 11.0 10.7 10.3 . 10.0 9.67 936 9.00 172 8.36 8.14 7.85 70 733 7.16 [-T 335 339 3.22 3.15 3.08 304 2.99 2.94 290 2.85 2.80 2.76 2.73 2.68 2.64 2.61 2.S 2.54 351 246 343 340 337 234 331 238 235 232 230 TABLE VI HEAT TRANSFER DATA for AROCLOR 1248 Fill COEFFICIENTS h nn*l roci^rwio* U5jtUOL^J Lu (McAdams; It4 m Ito* Dm* l.tT i I. Ml (1' I 11) ft) npmai to tta./s. It/to./*f FtOk RITE, (PM. f. 10 2.0 31 4.0 5.0 6.0 7.0 8.0 9.0 10.9 110 12.0 150 83i 86.2 938 103 m 123 130 200 44.9 63.4 78.7 94.0 109 124 138 151 164 179 191 250 33.5 58.5 9B.9 102 \72t 141 159 177 195 212 229 245 300 401 70.1 97 122 146 169 191 212 233 254 274 294 350 45J 79.0 109 137 164 190 215 239 262 286 309 331 400 491 851 111 149 178 206 232 259 284 309 334 358 450 53J 93 121 162 193 224 253 282 309 336 363 381 500 56J 98 138 171 204 236 267 297 327 356 383 411 550 C01 105 145 183 219 253 286 319 350 381 411 441 GOO 64.2 112 155 195 233 269 305 331 373 405 437 409 CMRRIim to attor pi* sftta cm to Ml (to toU toato ! TsMm IV ato V. to iiatoMitoi mn iMitoMil to to maa o% (to toyMi --toi ktoto* to-- 2188. HONS 0 7 1 5 6 8 FRICTION LOSSES IN SYSTEM PIPING AROCLOR 1248, ABOVE 300F. HEAD LOSS. FT. PER 100 FT. MONS 0 7 1 5 7 0 I TYPICAL HEATERS USING I AROCLOR l) i i 1248 ; * 2W.0 Blu. (rifIK) u4 t m.000 Bte kotar. Ml lastnd. 30 usuo n uo KitaT A (0.000 Btu. per hour electrically holed portable heat exchanger used lo heal msels of about SO gallons working capac ity. This unit was built lor a variety o( small stale chemical reactions. It was initially designed to vaporize approxi mately 700 Itn./hr. of an organic com pound nhich has a heat erf vaporization erf ISO Btu. per pound; a 10% heat kiss was allowed for. Experience with the heater indicates that a horizontal rather than the vertical mounting of the immer sion heater (at operator's left) would have been more satisfactory. ffcl IICMT A 4.000,000 Btu./hr. forced circulation International UMont heat*. IIOIT Control panel for a 1000,000 Btu./hr. iRttroatienal UMont heater that oper ates the 3.500 gallon, ftass-lined kettle shown on the left Thu kettle is the largest of its kind in Me United States. FAI II6IT Commercial heatan eperahng an Aroder 1241 areauaileMe in anycapacity dedred. This is a UOQ0O Mu./hr. inUPTna. 5 ! ! I Ml LEFT A pilot plan! resin processing vessel operated oo indirect heat transferred by Aroclor 1241. Vend end letter are mounted together in one unit. UFT This $00,000 8tu./hr. forced circulation heater is dectricalty heated and designed for a liquid temperature of 5O0T. The construction is uvular to a double pipe heat eKhanger with the electric heating 1 dements in the inner pipe; the Aroclor 1241 circulates through the aniular space between inner and outer pipe. The liquid Aroclor 1241 is delivered from the heater at a temperature of 500F. and heats (ho rantents of a jacketed kottle with a hatch capacity ol 1,800 ptem tffciX Ctmnmy Urm Inn Worin) % I i1 > * This do>gn hr a forced dr- LITERATURE CITED 1 i odatioa hoaiar was d| eohwd hy Ctamr Brooks 1. Monsanto Chemical Co., St. Louis, Mo.. Application Data Bulletin O-P-115 (1054). 2. Sullivan, M. V., Wolfe, J. K., ami Zisman, W. A, "Indus. Eng. Chcm.," 30, 1607 (1047). 3- Granet I., Heat Transfer Performance Curves", Chemical Engineering, P. 187-100, March, 1935. 4. McAdams, W. IL ``Hcat-TransmUdon", McCraw-Hill Book Co., Inc., New York, (J942). 5. Kern, D. Q., "Process Heat Transfer". McCraw-Hifl Book Co., Inc., New York; (1090).