Document dYdJVJ8jByGzreovBmrJg72GQ

2. Length of pipe and number of fittings. 3. Allowable loss in pressure from the outlet of the meter to the burner. 4. Specific gravity of the gas. xx. To obtain the cubic feet per hour of gas required by the burner, divide V? the Btu input at which the burner will be adjusted,' by the average Btu heating value per cubic foot of the gas. Iff) Capacities of different sizes and lengths of pipe, in cubic feet per hour, |.f with a pressure drop of 0.3 in. of water column for a gas of 0.60 sp gr,79 are shown in Table 1. In adopting a 0.3 in. pressure drop, due allowance^? for an ordinary number of fittings was made. Jsr,- To convert the figures given in Table 1 to capacities for another gas of|*j different specific gravity, multiply the tabular values by the multipliers^ shown in Table 2. '.'V Table 2. Multipliers for Various Specific Gravities _____ JpFor Use With Table 1 Specific Gravity .35 .40 .45 .50 .55 .60 .65 .70 .75 .80 .85 .90 Multiplier 1.31 1.23 1.16 1.10 1.04 1.00 .962 .926 .895 .867 .841 .817 Specific Gravity 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 Multiplier .775 .740 .707 .680 .655 .633 .612 .594 .577 .565 .547 .535 COMMERCIAL AND INDUSTRIAL GAS EQUIPMENT 1 No attempt can be made, due to space limitation, to describe or classigvfthe varied types of equipment used for commercial and industrial appUcjSSr tions. Much of the equipment utilized is custom built to suit a partied^ process. Certain standard parts such as venturi and burner head $0-$ ring burners, proportional mixers, or compressors, are purchased forjj^S sveidmebplyarinticeuxlaisrtiantgmoesqpuhipemreesnot,r ufosur aalnlynebaylinthge, sinosatkainllegr.pi,tsF,umrneatcaelsmelting!: etc. are usually engineered by industrial gas equipment manufacturere^g: Burners utilized in industrial equipment often operate at gas pressures;> higher than encountered in domestic usage. High pressure gas prowdj|yi flexibility of control required in the production of constant temperature^.; In addition, air-gas ratios can be closely maintained under throttling cdncfe tions, and heat liberation per cubic foot of combustion space is considerably) greater than can be achieved with lower pressures. A few of the many basic types of burners used are as follows: single-p'P?-/ high pressure, proportional mixing, pre-mix, two-pipe high pressure, atmospheric. '. The single-pipe high pressure burner system utilizes gas delivered orifice of a venturi at pressures from 10 to 50 psig. A constant press'^/ compressor, sometimes remotely placed, is occasionally used to increasfjyg Automatic Fuel Burning Equipment 381 gas pressure. The velocity of the gas issuing from the orifice entrains primary air which is controlled by an air shutter on the venturi tube. An advantage of this system is that when the gas pressure is reduced (lowering the input) the air-gas ratio will remain constant over a fairly wide range. In the proportional mixing burner, an enclosed type venturi, is used and high pressure air is delivered through an orifice. The resulting partial vacuum entrains the gas which is supplied through a zero pressure governor. When the air pressure is reduced, the amount of gas entrained is similarly reduced, thus maintaining a constant air-gas ratio over a side fuel capacity range. The pre-mix burner system embodies a compressor which mixes air and gas intimately and discharges the mixture through pipes to the burners GROSS OUTPUT-THOUSAND BT.UPER HOUR i~ i 02 ll 4 I I ~ 1~" I 68 l *H l | K> 12 \ l | l I T T* W B 18 20 CROSS OUTPUT - HUNDRED FEET STEAM RADIATION r-T--r-1--i--i .r-i--r-i--r--i----i--i--r--r--i--i--i--i--i--i--m--I--l~l "T"1 i "t r I O S 10 20 25 SO GROSS OUTPUT HONORED FEET WATER RADIATION Fio. 21. Coal Fuel Burning Rate Chart where it is discharged through orifices and burned'. The pre-mix compres sor can be remotely installed and the mixture can be closely controlled. The two-pipe high pressure burner system utilizes both air and gas under /Pressure, both being delivered through orifices and mixed prior to delivery . to the burner. The atmospheric burner system is not commonly used. It consists of a burner supplied with gas at a pressure of 2 to 12 in. water. A portion of the juror primary air required for combustion is entrained from the atmosphere cy the stream of gas issuing from an orifice, and the air-gas mixture is eiivered through a venturi mixing tube to the burner head and parts. * Pout 40 to 60 percent of the air required for combustion is.in the form of P mary air and the remainder, known as secondary air, is supplied from ne air surrounding the flame. ItEac|> system embodies characteristics essential for certain applications, y's,s^rongly recommended that proper and qualified engineering authoritrioi 6 coasulted prior to the purchase, installation, or operation of indus- al gas equipment.