Document dYXgw93DdG9KDJyD48X5yV7kG

ionsantoTRANSFORMER COOLANT BY Pyroclor is Monsanto's brand name for its fire resistant transformer eskarel. The term "askarel", as defined by ASTM, generally describes s broad class of fire resistant synthetic chlorinated hydrocarbon liquids used as electrical insulation media in transformers. Transformer askarels were first used in the United States in 1932 and incorporate chlorinated biphenyl -- one of the best liquid insulation materials ever developed. This inert material is chemically stable, fire resistant, heat stable, non-corrosive and has high dielectric strength under the operating conditions encountered in transformers. In Europe, askarel transformers form a large percentage of the distribution transformers installed today. In France, onB third of the distribution transformers brought into service each year are of this type. PYROCLOR 5 This is the recommended fluid for all Pyroclor-filled transformers operating at normal ambient temperature conditions. Should special operating conditions be envisaged, please consult with Monsanto -- it may be possible to provide a modified product. 0221137 1 TOWOLDMON0025809 WATER_PCB-00010278 Advantages of Pyroclor t. Pyroclor is very fire resistant. It resists ignition and tests have shown it does not burn continuously as a result of transformer arcing. 2. Pyroclor-filled transformers need no special fire precautions as part of the transformer installation. 3. Pyroclor-filled transformers offer greater siting flexibility, particularly where space is limited. They can be located indoors, close to working areas or at the load centre. 4. Properly sealed Pyroclor-filled transformers require little or no maintenance of the fluid over many years of service. B. Its permittivity is such that the distribution of electrical stress in the transformer is more uniform. 022U38 TOWOLDMON0025810 WATER_PCB-00010279 Sales Specification for Pyroclor 5 Property Appearance Colour Density at 20 C Refractive Index at 20 C Kinematic Viscosity at 20 C Fire Point Pour Point Neutralisation Number Inorganic Chlorides Scavenger Content (PPO) Water Content Electric Strength at 25 C, 50 Hz Resistivity at 100 C, 600V after 1 minute Dissipation Factor (tan 8) at 100C, 50 Hz Relative Permittivity 8t100C. 50 Hz Test Method ASTM D1702 ASTM D1702 ASTM D1810 and ISO/R 649 ASTM D1807 ASTM D445 ASTM D92 ASTM Monsanto ASTM D1821 Monsanto ISO/R760 IEC 156 Monsanto Unit -- APHA kg/mJ Value Clear liquid free from sus pended matter and sediment 150 max. 1502-1524 -- cSt c c mg KOH/g ppm Cl % ppm kV G ohm.m 1.6173 to 1.6193 32 max. None to BP -30 max. 0.01 max. 0.1 max. ca. 0.2 30 max. 45 min. 10 min. Monsanto % 5 max. Monsanto -- 4.2 to 4.5 Typical Properties (Not part of specification} Coefficient of thermal expansion (20 100C) Specific Heat (20 C) Thermal Conductivity (20*0 *C'i J.Kg-' c-* J m'1 sec'1 C'1 0.00073 1000 0.098 3 0221139 | TOWOLDMON0025811 WATER_PCB-00010280 Storage, Handling and Disposal of Pyroclor CAUTION: Pyroclor contains POLYCHLORINATED BIPHENYLS (PCBs) which some studies have shown may be persistent, an environmental con taminant, and, possibly, injurious to certain forms of bird, aquatic and animal life. Storage Inside storage of drums is recommended to avoid moisture contam ination. If drums have to be stored outside they should be stacked on their sides with bungs uppermost to prevent moisture being sucked in by breathing. Partially emptied drums should not be left open to the air. The supply of Pyroclor in bulk offers many advantages to medium and large users. Unloading, storing and transferring to the production unit is safer, easier and cheaper. Material losses due to spillage and incomplete emptying of drums is minimised. The possibility of product contamination during handling is greatly reduced. Even where storage and handling facilities are not atpresentavailable, the economics of bulk handling may quickly pay for the tanks and piping systems required. A booklet, indicating the type of system necessary, is available from Monsanto and experienced Monsanto personnel are available for site discussion regarding the most suitable bulk installation and off-loading procedure. It is essential that both drum and bulk storage areas should be organised so that leakages and spillages can be collected for safe disposal. 4 022114 j| TOWOLDMON0025812 WATER_PCB-00010281 Handling Transformer askarel has been made, handled and used for over 40 years. It can be handled safely if a few simple precautions are observed. t. Minimise contact with the skin by using gloves and other pro tective clothing. Remove accidental skin contamination as soon as practicable by thorough washing with soap and water. Short term exposure is unlikely to cause harm except to very sensitive skin, but long term exposure should be avoided. Remove saturated clothing and do not re-use until dry-cleaned. 2. Protect eyes with goggles. Accidental eye contact may result in painful irritation but no permanent damage to tissue. If Pyroclor gets in the eyes, flush with large amounts of water. As with all eye-first-aid, refer to a qualified physician. To relieve irritation, ophthalmic anaesthetic solution, ophthalmic cortisone acetate solution, or castor oil may be used under qualified supervision. 3. Avoid breathing Pyroclor vapour, mist or fumes. Infrequent exposure to Pyroclor vapour is unlikely to cause ill effects, but prolonged exposure to high vapour concentrations must be avoided. At normal ambient temperature, in well venti lated areas, the concentration of Pyroclor will be below that likely to cause harm. For handling hot Pyroclor in a confined space, a respirator with an active carbon canister should be worn. 4. Do not eat, drink, or smoke when handling Pyroclor. Although Pyroclor is not particularly toxic when ingested orally, this simple precaution will minimise hazard. 022U*1 TOWOLDMON0025813 WATER_PCB-00010282 Disposal of Pyroclor Waste Where possible the destruction of Pyroclor waste should be accom plished through carefully controlled high temperature incineration. This requires a special incineration facility providing a suitable fcalance between temperature, dwell-time, oxygen and auxiliary fuel pnd provision for removal of hydrochloric acid gas from the gasseous emissions. This facility must also make provision for handling the waste which may range from mobile fluid to solid, impregnated with Pyroclor.* If such a facility does not exist, subject to the provisions of local regulations, the waste should be consigned to a waste disposal site designated for toxic materials. Do not use empty Pyroclor drums except for waste Pyroclor. Before disposal they should be thoroughly drained and then flushed twice with kerosene type solvent. The solvent should be incinerated and the washed drums consigned to a waste disposal site. Alternatively Incinerate unwashed drums in a suitable incinerator. During handling and disposal of waste Pyroclor take great care to svoid pollution, particularly of drains and waterways. *Please ask Monsanto for up-to-date information on facilities available for incineration of Pyroclor. 022U42 TOWOLDMON0025814 WATER_PCB-00010283 Toxicity I. Inhalation At ordinary temperatures the chlorinated biphenyls in askarel have not presented industrial toxicological problems. The hazard of potential toxic exposure varies with their volatility; the lower chlorinated, more volatile ones present more of a potential problem from the standpoint of both inhalation and skin contact. When askarel fluids are used at elevated temperatures, engineering controls must be applied, either by the use of closed systems or by effective local exhaust ventilation together with general work room exhaust. Vapours of askarel at room temperature should not be breathed in a confined space and no vapour of any fluid evolved at elevated temperatures should be allowed to be dispersed into the general workroom. Inhalation tests on animals indicate that the maximum safe con centration of vapour is in the range from 0.5 to 1.0 milligramme per cubic metre of air. The threshold limit value (maximum allowable concentration of an 8-hour working day) set by the American Conference of Governmental Hygienists is 1.0 milli gramme of the lower-chlorinated biphenyl compounds per cubic metre of air and 0.5 milligramme of the more-highly-chlorinated compounds, per cubic metre of air. II. Skin Contact Prolonged or repeated skin contact with the askarel fluids must be avoided by the use of gloves and protective garments, because of the possible occurrence of a condition called chloracne. Although reports of this condition caused by askarel are rare, it can be produced by excessive skin contact. If the fluid is spilled on the skin, the skin should be washed in the usual manner with a soap solution. A burn caused by contact with a hot askarel should be treated like any ordinary burn. 7 0221143 | TOWOLDMON0025815 WATER_PCB-00010284 Labelling Precautions Pyroclor drums and containers carry the following label which gives general instructions for handling: IMPORTANT CHLOROBIPHENYLS (42%-54%) (or 60%) (PCB) This product contains POLYCHLORINATED BIPHENYLS (PCBs) which some studies have shown may be persistent, an environments! contaminant and, possibly, injurious to certain forms of bird, aquatic and animal life. PREVENT ANY ENTRY INTO THE ENVIRONMENT THROUGH SPILLS, LEAKAGE, DISPOSAL, VAPOURISATION, REUSE OF CONTAINERS OR OTHERWISE. SPILLS, LEAKAGES AND WASTE PRODUCT MUST BE COL LECTED. Use of this product must be restricted to applications which can be controlled so that entry into the environment does not occur and to applications in which it cannot come into contact with food, animal feedstuffs or pharmaceuticals. HARMFUL SUBSTANCE IF TAKEN INTERNALLY OR IF IN PRO LONGED CONTACT WITH THE SKIN. CAUSES IRRITATION OF SKIN AND EYES. DURING SHIPMENT AVOID SPILLS AND LEAKAGE INTO INLAND WATERWAYS AND THE SEA. Store away from food, animal feedstuffs and pharmaceuticals. Keep container tightly closed. Do not eat or smoke when using. Avoid breathing vapours, mist or fumes. Do not wear contaminated clothing. Wash product from skin with soap and water. Wash eyes by flushing with water. 8 022U** | TOWOLDMON0025816 WATER_PCB-00010285 All new-Pyroclor transformers should carry a label giving the follow ing Information:-- CAUTION The Insulating Liquid In This Transformer Contains Poly chlorinated Biphenyls (PCBs). Care Should Be Taken To Prevent Entry Into The Environment, In Case Of Malfunction Or Leaks, Consult The Instruction Manual Or The Manu facturer. References Reference should be made to the following publications for inform ation relevant to this bulletin. 1. Guide for Acceptance and Maintenance of Transformer Askarels in Equip ment. (American Institute of Electrical and Electronic Engineers Guide No. 76, (December 1958), (Revised edition) (I.E.E.E. Inc., 345 East 47th Street, New York)) 2. Guidelines for Handling and Disposal of Capacitor and Transformer Grade Askarels Containing Polychlorinated Biphenyls. (American National Standards Institute, Committee C 107,155 East 44th Street, New Yo'k.) 3. The Properties of Askarels and Recommendations for Their Use in Electrical Equipment. (C.I.G.R.E. Working Group 02, Study Committee 15, Electra&? (1974) 11-31.1 Fubllihad by MonMote 6urp 8.A. 16-31E1ME-1 (8/76) Printed In England. OE21145 s TOWOLDMON0025817 WATER_PCB-00010286 The information In this bullatin It to our btt knowledge true and accurate but all instruc* tlont, recommendations or suggestions ere mada without guarantee. Sine# tha conditions of vta art beyond thalr control, Monsanto Company and iti subsidiaries disclaim any liability for loss or damage suffered from use of these date or tuogestloni. Furthermore no liability la accepted If use of any product In accordance with that* data or suogastlont Infringe! any patent. The Information, recommendations and suggestions made herein ere offered In the light of prevailing legisletlo/i and on tha basis of prasant scientific Information (1976) available to Monsanto. 021114b TOWOLDMON0025818 WATER_PCB-00010287 Monsanto HEAD OFFICE Monsanto Europe S.A. Place Madou, 1 B-1030 Brussels, Belgium Telephone: (02) 219 11 01 Telex: 22110/21986 AUSTRIA: . Monsanto Gesellschaft mbH. ' A-1010 Vienna Rudolfsplatz 12 Telephone: 63 88 31 Telex: 07/6601 BELGIUM/LUXEMBURG: Monsanto Europe N.V. Mechelsesteenweg 163 B-2000 Antwerp Telephone: (031) 30 58 40 Telex: 31 657 DENMARK: Monsanto A/S 6 Rysensteensgada DK-1564 Copenhagen V Telephone: (01) 12.88.38 Telex: 19556 FINLAND: Monsanto Scandinavia AB Arkadiankatu 8 C 20 SF-00100 Helsinki 10 Telephone: 441186 Telex: 12841 FRANCE: Soci6t4 Monsanto 9. rue d'Argenson F-75008 Paris Telephone: 265 65 20 Telex: 65281 FEDERAL REPUBLIC OF GERMANY: Monsanto (Deutschland) GmbH. D-4000 Diisseldorf ImmermannstraRe 3 Telephone: 0211/3 67 51 Telex; 858-1307 ITALY: Monsanto Italians S.p.A. Via Melchiorre Gioia, 8 1-20124 Milano Telephone: 6273 Telex: 34659 NETHERLANDS: Monsanto N.V. Jan van Nassaustraat 53-55 NL-The Hague Telephone: 070/245015 Telex: 32208 NORWAY: Monsanto Norge AS Fred Olsensgt 11 N-Oslo 1 Telephone: (02) 20 48 58 Telex: 19106 POLAND: Monsanto Poland Inc. The Forum Hotel UI. Nowogrodzka 24/26 00511 Warsaw Telephone: 282613 Telex: 814704 SPAIN: Monsanto Iberica S.A. Lepanto 350 E-Barcelona 13 Telephone: 255 10 00 Telex: 53050 SWEDEN: Monsanto Scandinavia AB Ulvsundavagen 108 S-16111 Bromma-11 Telephone: (08) 80 28 30 Telex: 17359 SWITZERLAND: Monsanto (Suisse) S.A. Postfach CH-5600 Lenzburg Telephone: (064) 51 67 51 Telex: 66855 UNITED KINGDOM: Monsanto Limited 10-18 Victoria Street London SW1H 0NQ Telephone: 01-222 5678 Telex: 916093 oiz^1 J TOWOLDMON0025819 WATER_PCB-00010288