Document dYQ3L7MBvgaQxpmXR56pYz1RQ

April 17, 1967 AIRMAIL Mr. Torbet Phillips Petroleum Martinez, California Doar Mr. Torbet Mr. Ericsen of our Los Angeles office has asked me to send you toxicity information for our compreeaor lubricant Pydraui AC. A summary of the toxicity information may be stated aa follOHSi In animal toxicity studies with Pydraui AC. the oral lethal doae in rata is approximately 4o grama per kilogram and for rabbits, 3.5 to 4.5 grams per kilogram. The greater sensitivity of rabbits ia typical of this type of fluid. This lethal dose Is of such an order, however, that the fluid may be considered only ''slightly toxic" to man from oral doses. The fluid may be absorbed through the unbroken Bkln of rabbits in doses resulting such that accidental massive skin exposures to man do not present a hazard. Skin and eye irrita tion studies with rabbits classify the fluid as a mild irritant. Laboratory animals survived six-hour exposures to an atmosphere saturated with the vapors of the fluid. On the basis of this data, it is con cluded that Pydraui AC requires no apeoial handling precautions other than avoiding prolonged or repeated nkin contact. Accidental splashing in the eyes will result in moderately severe pain and irritation but no permanent damage should result. I am not sure what your particular application nay be that raises the question of toxicity, ./e have run some rather limited teata on a particular compressor where the air downstream showed no detectable levels of the lubri cant, nor any decomposition products. It must be pointed out, however, that there are many factors which could affect the DSW 018751 STLCOPCB4005295 :!r. Sorbet April 17, 1967 amount, if any, of any lubricant in the compresoed air. Some of those include the mechanical condition of the compressor, temperature of compressor cylinder walla, variations in operation, etc. If there were any thermal decomposition, we would expect to find JIC1, CO, COp, phenols, aldehydes, etc. depending on the degree of decomposition. It appears appropriate to us that, regardless of the type of lubrioant, if the air is to be used for breathing purposes, a filter should be placed in the line to remove not only any possible lubricant, but moisture, rust and any other possible contaminants. If I can be of any further service, please do not hesitate to let me know. Very truly yours, lUSKlCjs/* R. Emmet Kelly, M.D. Medloal Dlreotor act D, . Ericsen - Los Angeles .(A, 'A e< DSW 018752 STLCOPCB4005296