INTERNAL CORRESPONDENCE
CHEMICALS AND PLASTICS
ro (name) Mr. R. W. Sesler
company I.OCATIDH
Texas City Plant
copy to Mr. K. E. Ross
P, O, BOX 471, TEXAS CITY, T XA =, 'JlK)
DATE
August 8, 1975
VCM Emission Reduction
Attached is a list of VCM Projects grouped by area of
concern.
.'
it would be difficult to attach a number value for VCM reduction to any given project since the projects are in various stages of completion and the Solvent Vinyls Unit is down. The best statement that can be made is that the successful completion of all VCM reduction projects is a prerequisite to achieving <. 1 ppm exposure.
Following Unit start-up in mid-August and as the projects reach completion, VCM reduction data will be collected.
\
LJK/st Attachment
/
UCC 091488
VCM REDUCTION PROJECTS SOLVENT VINYL RESINS TEXAS CITY, TEXAS
Area Emission reduction
Employee exposure reduction
Varnish monomer reduction
Monitoring
o o 'O t--l
00 'O
Project Mech. seals
Purpose
M Dollars * Budgeted Expended
Reduce VCM leakage thru auto clave agitator seals
237.5
133.8
Mech. seals instr.
ditto
46.5
20.3
T.A. 1 seals
Reduce VCM leakage thru pump seals
15.4
3
B-117 press.
Positive pressure on control room
22 23.1
Dynatrols
Reduce autoc sampling
Stripping Still Reduce VCM in varnish
modifications
to .kLl ppm
148 41
84 43.4
North VFA complex
Continuous monitoring of VCM levels
46 15.5
S. VFA complex
Organic vapor analyzer
Ditto Survey for VCM leak sources
33 3.3
16 3.3
* Does not include engineering & overhead; $181M budgeted, $61.3M expended to date.
Estimated Completion 1st qtr 1976
4th qtr 1975
4th qtr 1975
4th qtr 1975
3rd qtr 1975 complete
3rd qtr 1975
3rd qtr 1975 Complete
L. J. Kunke August 8, 1975