Document dYK9p1EyB3oKb3Y3q0RQ4y1NR
INDUSTRIAL. HYGIENE REPORT
TEXAS. OPERATIONS:
FILE NUMBER:
DOW CHEMICAL USA AN OPERATING UNIT OF THE DOW CHEMICAL COMPANY
DATE ISSUED: PLANT CODE:
TITLE:
/un<e
DEN 3693
NOVEMBER 2, 1990
20400
EVALUATION OF WELDING FUMES AND TOTAL PARTICULATES AT THE DENVER EXTRUSION PUNT IN
Personal and area exposures to welding fumes and total particulates were evaluated in August, 1990, for employees working in the Denver Extrusion Plant at the new retorque welding station. Results of the eight components analyzed for welding fumes (welding fume total particulates, iron oxide fume as iron, copper, lead, manganese, nickel, molybdenum, and chrome), were found to be within acceptable limits.
Local ventilation was established for this welding operation. Capture efficiency of visible particulates was very good.
It is recommended that employees be informed of these sampling results and this documentation be sent to Industrial Hygiene Services for inclusion within the seventyfive year retention files.
DISTRIBUTION:
J. M. Boswell, M.D., B-101 D. E. Cragar, B-101 W. Demain, B-101 T. E. Yerina, Denver R. J. Higdon, Denver
Cover sheet only
G. W. Engdahl, 1803, Midland M. G. Swank, 1803, Midland *J. E. LeBeau, 1803, Midland *L. W. Rampy, 1803, Midland
OFFICE COPY
RESTRICTED FOR USE WITHIN THE DOW CHEMICAL COMPANY ONLY
DO 074949 CONFTDFNTIAL
IHS FILE #DEN 3693
PAGE 1
EVALUATION OF WELDING FUMES AT AT DENVER EXTRUSION PLANT, AUGUST, 1990
EVALUATION CRITERIA
Industrial Hygiene monitoring is performed to evaluate potential exposure levels to employees both as a daily time-weighted average (TWA) and peak or short-term exposures. The results of the monitoring are compared with the recommended exposure guidelines. The values are based on toxicology data and Industrial Hygiene experience.
Aoent
Welding fumes total particulate Iron oxide fume as iron
Copper fume Lead Manganese
Fume Nickel
Molybdenum Chromium Total Particulate
Exposure Guideline
5 mg/m3
5 mg/m3 10 mg/m3 0.2 mg/m3 0.1 mg/m3 0.15 mg/m3 0.05 mg/m3
5 mg/m3 (Cl) 1 mg/m3 3 mg/m3 (STEL 2) 1 mg/m3 1 mg/m3 5 mg/m3 5 mg/m3 1 mg/m3 0.5 mg/m3 10 mg/m3 10 mg/m3
Source*
ACGIH-TLV ACGIH-TLV OSHA-PEL ACGIH-TLV OSHA-PEL ACGIH-TLV OSHA-PEL OSHA-PEL ACGIH-TLV
ACGIH-TLV OSHA-PEL ACGIH-TLV OSHA-PEL OSHA-PEL ACGIH-TLV OSHA-PEL ACGIH-TLV
*ACGIH-TLV - American Conference of Governmental Industrial Hygienists
Threshold Limit Value
OSHA-PEL - Occupational Safety and Health Administration
Permissible Exposure Limit
(STEL 2) - Short-Term Exposure Limit - A 15-minute time-weighted average
exposure which should not be exceeded at any time during a
work day even if the eight-hour time-weighted average is
within the TLV.
(Cl) -
Ceiling Value - An employee's exposure to this material shall
at no time exceed the ceiling value given for that material.
DO 074950 CONFIDENTIAL
FILE #DEN 3693
TABLE I SUMMARY OF INDIVIDUAL AND AREA EIGHT-HOUR TIME-WEIGHTED
MONITORING - DENVER EXTRUSION
PAGE 2
JOB MASTER #/ CLASSIFICATION/AREA SOC. SEC. #
Area-on retorque Station B stand 3' from weld area
SAMPLE NUMBER
3342B
DATE
SAMPLE TIME MIN.
8-8-90
480
8-HOUR TWA
TWA EXPOSURES MG/M3
TOTAL
PARTICULATE Mo Cr
Ni Fe Mn Cu Pb
0.001
<0.001 <0.001 <0.001 0.004 <0.001 <0.001 <0.001
Unit Tech Fabrication
831496
2799-C-C 8-7-90
375
0.008
<0.001 <0.001 <0.001 0.009 0.001 <0.001 <0.001
Area-on retorque Station B stand 2' from weld area
3238-C 8-8-90
480
0.004
<0.001 <0.001 <0.001 0.007 <0.001 <0.001 <0.001
Area-on desk 10' from weld area
3238-D 8-7-90
370
0.009
<0.001 0.005 0.015 0.032 0.053 <0.001 <0.001
Area-on retorque Station 8 stand 3' from weld area
3342-D 8-7-90
375
0.005
<0.001 <0.001 <0.001 0.023 0.003 <0.001 <0.001
Unit Tech Fabrication
831482
3342-C 8-8-90
480
0.015
<0.001 0.002 0.016 0.008 0.001 <0.001 <0.001
Area-on retorque Station 8 stand 1 ' from weld area
2100-C-D 8-7-90
375
0.050
<0.001 <0.001 <0.001 0.038 0.006 <0.001 <0.001
General Contractor - Fabrication
196-58-5830 2799-C-D 8-8-90
480
0.024
<0.001 <0.001 0.001 0.008 0.001 <0.001 <0.001
DO 0 7 4 9 5 1 C O N F ID E N T !
Welding fumes were collected using calibrated Gi1 fan HFS513 air sampling pumps set at 2.0 1pm. A known volume of air was pulled through a pre-welghed 37um, 0.8 micron pore siie Gelman GA-4 membrane filter. After the filter's weight gain was determined, the filters were sent to Analytical Services (with blanks) for emission spectroscopy.
<indicates less than (analytical sensitivity of 1 ug)
X>