Document dYJZwRMyQ9anKv3q8vMz9Ngve
Environmental Protection Department South Charleston Plant
AUG 2 41976
.^August 23, 1976
To:
Mr. J- H. Murray Building 307-2
cc:
Mr. H. H. Frazier Mr. J. L. Worstell/Mr. W. C. Young SHARE Committee - 514
From:
Mr. B. L. Murray
Subject:
Potential of Asbestos Exposure From Storeroom Materials Plant Stores, Building 307-1 & North Charleston Storage Building 8-505 South Charleston Plant Project No. 514-H-307-8-505-76
Jim, as you requested, we have made an initial determina tion of the potential of asbestos exposure at the two storeroom locations in the South Charleston Plant including North Charleston Storage, Building 8-505.
In surveying these areas with Mr. Arlie Lynch and Mr. Ray Harris, the storage areas were found clean and orderly with minimal deposits of dust from asbestos material. However, as Mr. H. H. Frazier from the Institute Plant pointed out in his report (attached) of an asbestos dust exposure study, it is recommended to isolate the materials containing asbestos fibers. This could be accomplished by storing all materials in plastic containers including the asbestos cloth on rolls. In this way the employee dispensing the material would be freeing the bulk of the asbestos dust inside of the plastic container.
According to Arlie the majority of the asbestos containing material is dispensed as stored and eliminate the untangling and preparation of small quantities of the material.
Based upon these observations, compliance with the program of isolating the asbestos containing material, and the air sampling results from Mr. Frazier, we feel that the potentialfor exposures of the stores employees' to asbestos dust exceeding 2 fiber/cc greater than 5 fa in length will not be exceeded.
An Environmental Health Data Sheet is attached for Asbestos.
/pi Attachment
UCC 011655
UNION CARBIDE CORPORATION
CHEMICALS AND PLASTICS DIVISION
ENVIRONMENTAL HEALTH DATA SHEET
SOUTH CHARLESTON PLANT
SECTION I
HEALTH HAZARD NIOSH
Manufacturer's Name
Chemical_____Asbestos
(Chrysotile) Serpentine Chemical Family______________________________
Trade Name
Formula 3MgO. 2Sf O2 *2H20
Magnesium Silicate
'
Good heat resistance
;
High tensile strength and
SECTION II - Physical Properties flexibility
'
Boiling Point (F)
__Specific Gravity 2. 5
Vapor Pressure (mmHg)
Vapor Density (Air=l)
%Volatile by volumeSolubility in water
Odor-Characteristic (TO)_______ Flash Point (F)NA
Molehular Weight
**5f/ml>5 fa long
Decomposition Products_________ _TLV(PPM)Melting Roint (C)
,/^ower Explosive Limit (LEL)^ Action ' evaporation Rate (Butyl Acetate-1)
Explosive Limit (UEL) Color - White
SECTION III - Health Hazard Data
Ingestion - LD5Q
If accidentally swallowed, report to the Medical Department.
Skin Penetration
Wear protective clothing. If contacted, wash affected skin areas
with watei. Vacuum protective clothing befoie removal.
.
Skin Irritation -
Breathing -
Eyes -
'
Wear protective clothing. If contacted, wash affected skin areas with water. Maintain and laundry protective clothing. Store, transport and dispose of clothing in sealed non-reusable containers marked "Asbestos - Contaminated Clothing". Prolonged inhalation of the asbestos particle may cause delayed lung injury. Wear respiratory protection and use with adequate ventilation. If exposed, wash eyes with water. Report to the Medical Department
Spills - Clean up - wet the material before handling where possible. If loose material
must be cleaned up dry, use vacuum cleaning or sweeping compount to keep .
dust under control.
,
*.
Waste Disposal - Collect in plastic bags - Landfill.
^
:.
Air Sampl ing and Analysis -- Collect on membrane filter and analyze by phase contrast
illumination.
** - 8 hour time-weighted average 2 f/ml>5/u effective July 1, 1976
OSHA is proposing 0.5 f/ml 5^u - ceiling limit 5 f/m>5 u.
"
, ,
Hff 0.J,
C /M Te; <T-.` A r& A- &
of
-- <J
m di
-
UCC 011656- ---- ---V,--
J. R. Buzzard, 31A G. P. Durocher, 526 P. F. Genty, 510 P. G. Harvey, 519 B. R. Hutson, 511 R. W. Jones, 312 W. R. Kimberling, 511 J. A. Lawrence, 513 . C. Litteral, 511 R. 0. Lohman, 293 J, E. Hurray, 515 J. H. Hurray, 51^ H. C. Reading, 515 J. V. Safety, 380
opy To: P. H. Day, 512 H. S. Eastman, 511 A. Walker, NYO-21
Asbestos Exposure
Gentlemen:
Attached is a report by the Institute Plant industrial Hygiene Department on the potential of asbestos exposure when dispensing storeroom materials.
The highest levels of exposure were obtained when handling Flexitallic gaskets and asbestos rope.
After examining the report, you may want to review your safety procedures for these items.
Very truly yours,
ROS/wkm Attachment
R. 0. Spencer
UCC 011657
<*0*^ ' `
thijJU^u f.
A i
JEMICALS A NO HA'IICS
* Mr. P. II. Day ^
tnr
Mr, J. E. McDermott, Jr. Dr. R. J. Sexton Mr. F. Williams
I*** .!}() * t ` ** | ' 'I
i .)!* ' : i
July 9, 197b
Mm-,-
, i ICR - 1 mlus t r i a 1 llygi ene
* .i
limp 1 oycc_ Exposure to Asbestos - Plant Stores'; building 330
In response to questions by Plant Stores Employees, you have asked for asbestos exposure levels to be determined at certain Locations williin lluildlap, 330. Evaluating of storage conditions and dispensing methods lias been made together with appropriate area and personal sample collection. The conditions of sampling and results are reported as follows:
SAMPLE DATE
TYPE SAMPLE
SPECIFIC LOCATION AND/OR CONDITIONS
ASBESTOS FIBERS/ML AIR
COUNT
TLV
6-7-76 6-16-76 6-16-76
6-16-76
6-16-76
6-16-76 6-16-76
Area
Asbestos rope storage and dispensing. 0.13
Personal*
employee untangled and prepared 10//
.
of 3Ik" Asbestos Rope for dispensing- 0. 76
Personal* e Employee replaced rope in bin and
swept aisle of fallen fibers - five
minutes.
0.0
Area
3' above rope storage bin - during,
two five-minute sampling, periods
^Uc...... ......... ....-- --
-
x 0.33
Personal* /During five-minute sampling, period, \
f Employee Simulated filling, gasket
1.0^
orders from Row A3, 46, and 91 bins.
Area
~-A--1/2 feel aTtTrm'^itnw'A 1 gasket bins '
during, personal, .sampling above.
().()
Area
(>" above.1 floor during, above sampling,--
includes three passages through
aisle and two trips on i. rnnspor l < r.
0.0
2.0 2.0 2.0 2.0 2.0 2.0 2.0
*All personal samples were, collected on 1 lie person of and wllh (he eonpornl Ion of Mr. R. 0. Hanna. A 3M rasp iralqr_ w.pswojnlryjlr._i lamia,at. our leanest ,
The. potential for excessive employee exposure to a:die::lon fibers Is apparent at the different storage bin local.ions and especially al the asbestos rope dispensing bin. Each time rope or gaskets are removed from the siorage bin, asbestos fibers are released and are plainly visible. liberated fibers an; deposited and/or are accumu lated on the floor with the potential of becoming airborne due to sweeping or generated air currents.
Although the potential for excessive exposure appears to be serious, the results obtained during our sampling evaluation are well within Lite limits of the new Tl.V of two fibers greater than five micrometers per milliliter of air. One reasonable explana tion for the lower than expected values is that fibers being liberated are large and of sufficient density that they do not easily become airborne. Asbestos must, nevertheless be controlled wherever possible.
UCC 011658
<* "
- I-
Fdf.'llly, ashesl os run I a i n i ug iii.'tt cr i .11 s would ]>r stored in ;i sepa ml o room, liav i ng proper vcnl i lalion, al I oea I. i on:; such .1:; I'l.m! Si hits. Our measuremml s , liowrvi'r, ilo not i n<l i ea 1.0 exposure level;; of .1 magu i I tide i n justify isolated *;1 mange as a requirement. We do ol rev recommendat i on:', for your eons i der.at iou, a:; follows:
FT H ST: Relocate l lie storage. a rea of 3/V ash.-st or. rope to a more retnol r area of I tie building where, there is less order Ci.il in)- , 1. - i ivily. I'rovide a partially enclosed spool type dispenser to avoid work with an entangled mass of maferial, which .appears to he encountered each time an order is N lied. Anoihsi opt ion would he to have employees wear 3M Respirators and prepare pre-weigiied or I engl Ins of rope in plastic bags for ready order filling.
SECOND: Consideration be. given l;o individual and/or nmni uumhers ol melal reinforced gaskets being stored and dispensed in p.laslic bags.This praetire would avoid possible exposure of employees other than Stores personnel in asbestos liberated from the gaskets through handling until final appfieat. inn.
THIRD; Make 3M Respirators readily available to all Stores personnel for list' during asbestos and other job Lusks where need for a respirator is apparent.
Please Inform Mr. Hoffman and Mr. Carey of the result:', of the above listed samplings and should there be further questions, please, call ine.
HHF/kjs
H. II. Fra/, i ei '
UCC 011659