Document dY0NoYry7OLJoRDVmGa32BXze

& Diamond Shamr ck >P PVC- Interoffice Correspondence To: From: Date: D. E. Frey E. L. Payne December 3, 1981 Subject: Safety, Environmental and VCM Reduction Report - November, 1981 cc: R. Becker/R. Beadle/F^^aoksi - Las Colinas /L/R. -frFnnnggd- - Pasadena D. Henderson/G. (LLark - Safety R. B. Kitchen/M. L. Pulley M. Labovitz/R. A. Paradis - Concord B. Lochridge/C. Schock/W. Mott D. Lull/R. Stellenberg/D. Bobish - Delaware City J. Seraancik - Concord R. Nagy - Las Colinas J. Worthington - Dallas D. P. Tech File 16.03b (2) I. Personnel VCM Exposure There were no ceiling values above 5 ppm out of 45 samples. There was one TWA value above 1 ppm out of 48 samples. A mask was worn during the TWA exposure. Ceiling Exposure (ppm) Department Resins #1/2 Resins #3/4 Resins #5 LP&S Compound Labs Maintenance Tech & Adm. Pit. Overall Plant Supv. High .78 1.69 2.65 0.51 1.68 1.88 1.57 4.30 4.30 Low 0.05 0.04 0.38 0.02 0.03 0.24 0.60 0.47 0.02 Avs- 0.53 1.02 1.13 0.24 0.69 1.06 1.27 1.58 0.92 Samples 10 7 7 5 3 2 6 5 45 TWA Exposure (ppm) Resins #1/2 Resins #3/4 Resins #5 LP&S Compound Labs Maintenance Tech & Adm. Pit. Overall Plant Supv. 0.41 0.38 3.71 0.07 0.05 0.22 0.24 0.22 3.71 0.10 0.09 0.02 0.01 0.04 0.01 0.02 0.03 0.01 0.26 0.22 0.63 0.03 0.04 0.12 0.08 0.16 0.23 11 7 7 5 3 2 7 6 48 OCC 11042 Safety, Environmer^^. and VCM Reduction Repo^- November, 1981 December 3, 1981 Page 2 Residuals High Low Avg. Samples Product PVC 426 PVC 450 #1/4 PVC 470 PVC 500 PVC 550 Exp. & 0G Resin All Paste All Compound High 80.80 1.36 3.65 6.60 0.19 1.62 1.92 2.67 Low 0.01 0.01 0.01 0.01 0.01 0.01 0.04 0.01 Avg. 6.16 0.30 0.50 0.78 0.08 0.75 0.41 0.46 Samples 80 26 25 49 8 9 19 22 III. Environmental Air A. The highest reading at the Plastics battery limit was 0.01 ppm. The highest reading at the Deer Park Works boundary was 0.01 ppm. B. Leak Patrol A total of 2194 points were checked. There were 12 new leaks detected. There were 10 leaks repaired with 3 leaks remaining to be repaired from the current and previous audits. C. There was 1 reportable VCM release during the month. On November 19, 1981, a release occurred at the waste water stripping surge tank when the relief valve lifted, releasing 225 pounds VCM. The tank became overpressured as the result of some liquid vinyl being drained along with the water from #5 Plant's reclaim decanter D. There were no reactor openings above the standard. IV. Environmental Water A. The highest level of VCM in plant effluent to the ship channel was 0.02 ppm. The highest level of VCM in the storm sewer was 1.00 ppm B. There were no samples from the #4 Outfall above the NPDES permit limits. Values above NPDES limits: Month YTD 3 C. Wastewater Stripping There were no waste water daily averages above the standard this month. Values above standard: Month 0 YTD 10 CC 11043 Safety, EnvironmeiWrL and VCM Reduction Report - November, December 3, 1981 Page 3 1981 V. Reclaim System/Flare Flare Use in Hours Month * Permit Year: 2/1 to 2/1 VI. Environmental Statistics A. Suspension Stripping Month Daily Average (ppm) Days Above Standard Limits 89.00 B. Dispersion Stripping Daily Average (ppm) Days Above Standard Limits 716.50 0 C. Waste Water Stripping Daily Average (ppm) Days Above Standard Limits 0.99 0 D. Reactor Openings Number of Charges Number of Reactors Sampled Number Above Standard Limits Percent Above Standard Limits West Plant Charges/Opening East Plant Charges/Opening 2,243 42 0 0 1/1 2/1 E. EPA Reportable VCM Releases Number of Releases 1 F. Total Reportable VCM Releases Number of Releases 1 G. Outfall 004 Number of Samples Above NPDES Permit 0 Permit YTD 16.5* YTD 82.16 3 656.53 4 1.79 10 28,390 409 6 1.5% 5 8 3 OCC 11044 Safety, Environmental and VCM Reduction Report - November, December 3, 1981 Page 4 1981 Total VCM Emissions from Stripping and Reactor Openings A. Suspension Resin Stripping Month YTD ERA Permitted Emission-lbs. Texas Permitted VCM Emission-lbs. Actual VCM Emissions - lbs. Over/(Under) - lbs. (Texas) 10,247 5,550* 2,280 (3,270) 121,638 61,050 24,984 (36,066) *Permitted based on 555 MM lbs/yr. production (permitted by the state of Texas). B. Dispersion Resin Stripping Month YTD EPA Permitted VCM Emission-lbs. Texas Permitted VCM Emission-lbs. Actual VCM Emission - lbs. Over/(Under) - lbs. (Texas) 940 1,167* 337 (830) 27,816 12,837 9,131 (3,706) ^Permitted based on 20 MM Ibs./yr. production (permitted by the State of Texas). C. Reactor Openings Permitted VCM Emissions - lbs. Actual VCM Emission - lbs. Over/(Under) - lbs. (Texas) 522 232 (290) 6,359 3,668 (2,691) D. Totals EPA Permitted VCM Emission - lbs. Texas Permitted VCM Emission-lbs. Actual VCM Emission - lbs. Over/(Under) - lbs. (Texas) % of Permitted Emission (Texas) 11,709 7,239 2,849 (4,390) 39% 155,813 80,246 37,783 (42,463) 47% VIII. Injury Report Lost Time Cases Month YTD #1/2 Resin 00 #3/4 Resins 00 #5 Resins 00 Compound 00 (cont'd on next page) Lost Workday Cases Month YTD 00 00 00 00 Recordable Cases Month YTD 01 01 01 00 First Aid Cases Month YTD 0 10 0 13 05 00 OCC 11045 Safety, Environme^kl and VCM Reduction Rep^ff - November, 1981 December 3, 1981 Page 5 VIII. Injury Report (cont'd) Lost Time Cases Month YTD Maintenance Labs LP&S Tech.-Admin. 00 00 01 00 TOTAL PVC 0 .1 Lost Workday Cases Month YTD Recordable Cases Month YTD First Aid Cases Month YTD 0 0 0 0 1 18 0 0 1* 1 0 4 0 1 0 2 0 18 0 0 0 0 0 ' _2 0 1 1 6 1 68 * A senior lab technician suffered a laceration to the middle finger of his left hand, which required sutures, while feeding mill stock to the mill rolls. E. L. Payne ELP:sg OCC 11046