ERNIE S7TEET SHERWIN ASBESTOS November 29, 1983 In the early 1960's, RMC recognized the inherent breathing problems associated with overexposure to asbestos-containing materials and recom mended that exposure be controiJed to within the threshold iimit value. It was not until the late 1960's that evidence began to mount regarding asbestos and its cancer causing potential. As a result, RMC reiterated its earlier recommendation that asbestos-containing products should be handled with great caution. In 1973, we recommended that the machining of asbestos-containing materials, such as molten metal marinite, transite, and brake shoes, be discontinued and non-asbestos substitutes be introduced wherever possible. Since January 1983, Corporate Medical and CentraJ Engineering have been conducting an extensive asbestos audit in all operating facilities, in an effort to eliminate any inhalation exposures to asbestos. This goal is being achieved through the use of non-asbestos products for the remain ing "current use items" and the adherence to strict work practices when handling "in place" asbestos. In the meantime (November 1983), QSHA has issued an Emergency Temporary Standard for Occupational Exposure to /Asbestos which lowered the permissible exposure level (PEL) from 2.0 fibers per cc to 0.5 fibers per cc, on an 8-ho , time-weighted average basis. ctunately, a review of personal monitoring data indicates that, since we plave eliminated the machining of asbestos-containing products, the only exposures which would be at or above the new PEL would be those involving the demolition or removal of asbestos-containing material, such as bulk thermal insuiation, that is already in place. Work practices have been im plemented, however, for the demolition and removal of asbestos-containing products, and inhalation exposures in these situations have been eliminated. In order to ensure compliance with the new Asbestos Emergency Temporary Standard, it is necessary that all facilities undertake the following measures concerning the demolition of asbestos-containing products: 1) Using the Medical/Central Engineering Departments' asbestos audit report, identify all jobs and employees involved in the demolition of asbestos-containing products. R-tOO-65 003589 INDUSTRIAL HYGIENE BULLETIN #121 ASBESTOS Page Two November 29, 1983 2) Contact the Industrial Hygiene Department, to facilitate the necessary monitoring to determine exposures during the demolition of asbestos. 3) With the assistance of the Industrial Hygiene Department, conduct training of all employees who may be exposed to asbestos in excess of the 0.5 fibers/cc PEL. Attached is a summary of the standard. If you have any questions regarding its application to your operation, please call the Industrial Hygiene 0epartment. At t. Homer M. Cole Manager Environmental and Industrial Hygiene Distribution: EH-1 RD-01 RD-70 BP-54-Tab 5 MP-15 003590 ' DEPARTMENT Of LABOR Occupational Safety and Health Administration 29 CFR Part 1910 (Docket No. H-Q3301 Occupational Exposure to Asbestos aoemcy: Occupation Safety and Health Administration (OSHA). Labor. action: Emergency temporary standard. PART 1910--{AMENDED! Section 1910.1001 of Part 1910 of Title 29 of the Code of Federal Regulations is hereby amended by adding a new paragraph (k) reading as follows: f 1110.1001 Asbestos. s (k) Emergency temporary standard effective November 4.1963.--(1) Scope. This emergency temporary standard is issued pursuant to section 6(c) of the Act and applies to all workplaces where employees may be exposed to asbestos in all industries covered by the Act. including, general industry, construction and maritime. Except to the extent modified by this emergency temporary standard all provisions of $ 1910.1001 remain in effect. , (2) Permissible levels ofexposure. "j? The 8-hour time-weighted average airborne concentration of asbestos fibers to,which any employee may be exposed shall not exceed one-half (0.5) fiber, longer than 5 micrometers, per cubic centimeter of air. as determined by the method prescribed in paragraph (e) of this section. (3) Methods of compliance with the emergency temporary standard. Notwithstanding any other requirements of this section, compliance with the reduced exposure limit of 0.5 f/cc shall be achieved by any feasible combination of engineering controls, work practices, and personal protective equipment and devices. (4) Employee information and training--{i) As soon as possible, but not later than thirty (30) days from the effective date of this emergency temporary standard, the employer shall institute a training program for all employees exposed to airborne concentrations of asbestos in excess of 0.5 f/cc. without regard to the uae of respirators and shall assure their participation in the program during the effective period of this emergency temporary standard. (ii) The employer shall assure that > each such employee is informed of the following: (A) The health effects associated with asbestos exposure: (B) The relationship between asbestos and smoking in producing lung cancer. (C) The nature of operations which could result in exposure to asbestos and necessary protective steps to minimize exposure including, at applicable, engineering controls, work practices, respirators, housekeeping and protective clothing: (D) The purpose, proper use. fitting instructions and limitations of respirators permitted by the standard: and (E) A review of all the provisions contained in 1910.1091.' (5) Respiratoryprotection during the 75. Notwithstanding any other requirement af this section, where respirators are used to achieve the permissible exposure limit of 0.5 f/cc they shall be selected according to Table 1. (6) Warning signs during the 75. in addition to the reouirements of paragraph (g)(1) of this section, legible signs warning of the health hazards of asbestos shall be provided end displayed at each location where airborne concentrations of asbestos fibers may exceed 0.5 f/cc. TA8LL l Respirator/ Protection For Airborne Concentrations of Asbestos Airborne Concentration of Asbestos (TttA) let in excess of 5 f/cc oo z pa) Mot in excess of 50 f/cc vl00 X Pa; treater then SO f/cc Required Respirator1 Reusable or single use air purifying respirator Full facepiece air purifying respirator, or a powered air purifying res pirator A type "C* continuous flo or pressure demand, supplied air respirator. * Respirators specified for high concentrations nay be used at tower concentrations of asbestos. (Sect. 6(b). 6(c). 6(c) and 6(g). Pub. L 71*596. 84 Slat. 1593.1596. 1599.1600: 29 U.S.C. 655. 6S7: Sec. 107. Pub. L 91*54. 63 Slat. 96 (40 U.S.C 333): 29 CFR Pan 1911. Secretary of Labor < Order No. 9-63 (48 FR 35736)) im Ooc 0-073 FiM 1W-C3 l i pm| IUM COOC 44M-K-M 003591