Document dQp5vY4a9kKRKOr4OjXq74QL6
E. I. du Pont dc Nemours & Company Wilmington. Or aware 19898
LXOAL OCPARTMfVT
October 16. 1984
Docket Officer Docket No. H-033C Boob S-6212 U.s. Department of Labor Third street end constitution Ave.. N.w. Washington. D.C., 20210
Re: occupational Safety and Healtn Administration Proposal to Revise 29 CFR S1910.1000 - Asbestos Post-Hearing Brief of g. I- dPont do Nemours sad Company
Dear Sir:
In the pre-hearing comments of S. I. du Pont dm Nemours and Company (Du Pont) re the* above-referenced proposal, the company cequesteO to subait for the record a study it was conducting on workplace protection factors for ela.komerie half-aask and single use respirators. The study was begun in 19S3 and was not completed in time to present at the public hearings in June and July. The study is now finalized and is attached as exhibit A to these comments.
The authors of the study are Stephen w. Dixon, Supervisor, industrial Hygiene. Haskell Laboratory for Toxicology and Industrial Medieiae, and Thomas'J. Nelson, Coordinator. Industrial Hygiene. Finishes and Fabricated Products Department. Because the authors are considering publication, we would appreciate limited distribution of the study.
The Du Pont Bosnlritor.Study
In the Du Pont respirator study, workplace protection factors for elastomeric and single use half-aask respirators
S99
DUP 0907323 DU 028424
Docket Officer
-2-
October is. 1994
vara measured during asbaacoa raaoval operation*. In addition two workplace protection (actor measurements war* mad* for a self-contained breathing apparatus operated in tb* pressure-demand aod*. Tb* o;srations consisted of asbestos raaoval from a ceiling (fir* proofing) and reaoval of pips insulation.
Results of tbe study showed that all respirators tested reliably provided workplace protection factors of ten or greater except tb* American Optical (AO) R10S0 wbicb reliably provided a protection factor of five or greater (based on tbe best estimates of tbe 5th percentile of workplace protection factors). Results for tb* self-contained breathing apparatus suggest that it may not provide appreciably better protection than tbe disposable and elastomeric facepiece respirators, though it created a significantly greater safety hazard (i.e.. falling due to difficulty balancing tbe heavy tanks when climbing scaffolding, etc.).
Much of tb* bearing testimony regarding adequacy of respiratory protection, particularly for disposable respirators, was conjecture. The Du Pont study provides tbi only data which measures tbe protection provided by elastomeric and single use half-mask respirators foj: asbestos exposures in asbestos removal operations. Based on this information, the OSKA standard should permit use of these respirators.
OSHA should adopt a performanea-based work practices standard for insulation reaoval and permit us* of elastomeric h*j.r-mask and disposable respirators It these japetations.
As stated in Du Font's pre-hearing comments, the company urges OSHA to adopt a flexible, performance based standard which permits the us* of respiratory protection to achieve compliance where engineering controls are not feasible, such as in the removal of old asbestos insulation. Even witnesses generally opposed to the us* of respirators in workplaces where there is potential for exposure to asbestos agree that there are instances where respirators are the only feasible control measure. At the OSHA bearings on the asbestos proposal the National Institute of Occupational Safety 6 Health (NIOSH) stated:
"However, prior to the installation of or during the malfunction or maintenance of these engineering . controls, for short-term intermittent exposures and
DUB 0907324
DU 028425
Docket Officer
- 3 October 16. 1984
foe certain operations chat act performed at constantly changing locations, a need for respirators doss exist."(D
The final standard should acknowledge that respirator use will be the only adequate control for sobs activities and it should allow employers the flexibility to select protective equipaent based on aa assessaent of the potential for exposure and the individual performance capability of the respirator.
Infeasibility of supplied air respirators in insulation
rewoval_______________
_______ __________________
Air line respirators or self-contained breathing apparatus (SCSA) create safety hazards in a complicated reaoval operation where workers are constantly cliabing and descending ladders or scaffolding because of the increased risk of tripping or falling. In addition, the Halted data available in the Du Pont study suggest that contrary to the general assuaption. supplied air respirators nay. not provide
appreciably better protection than air purifying respiratorr.
In view of the documented effectiveness of elastomeric half-aask and disposable respirators. Du Pont urges OSBA to
permit use of these protective devices In insulation reaovart
operations where expected concentrations will not exeeed the use Halts applicable for a particular type of respiratory protection equipaent.
OSHA should provide additional opportunity to coaaent on
the proposed standard
_________________ _
The preaable to the proposed standard discusses many regulatory possibilities which ace not contained in the actual
proposed standard. It is. therefore, difficult to identify precisely what the Agency is proposing and provide aeaningful input. Consequently. Du Pont requests that OSHA not proceed froa this coaaent period directly to a final standard: instead,
the Agency should reissue a revised proposal reflecting the inforaatioa received in this proceeding and solicit additional
coaaents on this revised version.
(1) See testiaony of the NIOSH transcript of the OSBA asbestos hearings on June 21. 19S. page 73.
DUP 0907325
DU 028426
Docket Officer
4 October 16. 1984
la summery. Du Pont supports OSHA's decision to reduce exposures to asbestos. Foe the specific Activity of removal of old asbestos insulAtioa, engineering control* at* not effective in controlling exposures to lsss then 0.5 fibers/cc; consequently, respiretory protection should be pecnitted. The use of respirators will effectively control exposures as demonstrated by Du Pont's field study for negative pressure respirators.
If you have questions regarding any Du Pont materials submitted to the asbestos rulemaking record. I may be reached at 302-774-8284.
Very truly yours.
JLP/cde Att.
Julia L. Phillips Attorney Environment. Materials &
Ldgistics Division-
DUP 0907326
DU 028427
RESPIRATOR workplace protection factors for ASBESTOS SUMMARY AHPLiACKCROTOP
Workplace protection (actors oc elastomeric and single use half-aaslc respirators wart measured during asbattoa raaoval oparation*. Tha operations consistad o asbestos removal from a calling (ira proofing) and removal o pipa insulation. Tbe usa o vater/surfactant solutions to spray fira proofing and insulation resulted in conditions of high humidity for in-doors operations. Out-of-doors operations vara also under high humidity conditions since ligbt rain occurred on two of four days of out-of-door, sampling. Temperatures for both operations vara in tha 6S-SS*? range.
The respirators vara used In the context of a respirator program that folloved the guidance in 29 CFS 1910.134 and AMS1 Zia.2 (1980) including proper respirator selection and fit testing. A total of seventeen volunteers participated in tha study. One or tvo vorkplaee protection factors vara determined for each respirator for vhich tbe fit test bad bean passed.
The respirators tested vere: One successfully fitted elastomeric facepiece
respirator ehosen for comfort from six respirators (MSA Comfo II and Survivair 2000 brands - small, medium or large sizes). Tbesa respirators vere tested using a dust, fume and mist type filter and a high efficiency filter.
DUP 0907327
DU 028428
2 lieu of three disposable respirators successfully
fitted (3M 9910. 3M 8710 and American Optical aioso). A successfully fittad North 7700 elastoaeric facapiaca racoirator. chosen fro* the saall. aediua or large aiza facapiaeaa. la additioa rwo workplace pcotaetion factor asasuraaents vara aada for a self-contaiaed breathing apparatus oparacad ia the pressure-deaand aoda. Basults sbovad that, with tha axcaptioa of tha Aaarieaa Optical (AO) B1050. all caspirators tastad reliably providad workplace protactioa factors of tan hr graatar based on estiaates of tha lower Stb pareantila. Tha AO 110S0 reliably providad a proieetioa faetor of five or greater. These results are coasistaat with iafosaatioa supplied to the record by Los Alaaos National Laboratory which reported oa tha penetration of asbestos through respirator filter aedia.(1,} Basults for tha self-eoataiaed breathing apparatus suggest that it aay aot provide appreciably batter protection than tha two batter disposable respirators aad the elastoaaric faeapiaee respirators, though it creates significantly,graatar hazard of falling because of tha weight aad awkwardness of the tanks. Myhre at al.t2* aad Bavaa(3) have shown that pressure-deaand type respirators do not aaintain positive pressure inside the facepiece when workloads are increased froa
DUP 0907328
DU 028429
rest condition*. Thi* aay explain in part wny no significant difference exists between half facepiece negative pressure and pressure-demand respirators. PROCEDURE
Prior to tasting, each parson was trainad in tna salaction and fit testing of respirators using the National Paint and Coatings Association Training Prograa*4*. Eaeb was than fit tested using tbs sacebarin fit t*st^4). Respirator* elected for usa by participants ara listed above and in Table I.
Two individuals vara also trainad in usa of a prassura-daaand self-contained breathing appa'ratus. pit tasting was not dona, at it is not raguirgd for pr*ssux*d*nand equipment in the ANSI ZII.2 (19*0) standard.
During saapla collection, aacb participant was observed continually to ensure that the saapla train raaainad intact and did not intarfera with tba respirator seal on tba face, and to note oeeuranees which night have affected respirator performance. sucb as movement of tba respirator on the face. Tba participants vers very busy vitb their work activities and soon ignored tba presence of tba researchers. AIR SAMPLING AND__ANALYS1E
To determine the workplace protection factors, concurrent saaples were taken ftoa inside the respirator (in-aask) at nos* level and outside the respirator at the
DUP 0907329
DU 028430
-4 lapel (lapel). Closed-face Glascock (#1505) cassette filter holders fitted with Half inch extenders and probes developed by NlOSH(5) vara used dor both tba in-mask and lapel saaplas. The saapla probe* are cpacially designed to minimize tba los* of particulates. The cassettes contained 0.8 ua, 25am cellulose ester filters.
The sample trains were calibrated before and after taking each saaple using a aass flow aster. The aass flow aster was calibrated against a bubble flow aster at the beginning and end of the study > flow rat* of 2 Lpa was used for in-aask samples. Lapel saaples were taken at o.s-l.o Lpa to avoid overloading.
Saaples were collected for a on*.to two hour period. Each saaple represented a single wearing of the respirator.
Fiber eounts were done per NIOSH procedure PfcCAM 239(6) (phase contrast aieroseopy/. except that the triacetin/acetone aounting aethod was used as described in NIOSH aethod 7400^. Counting was done according to the "AM counting rules in method 7400. Five hundred fields were counted for in-aask saaples to increase analytical sensitivity. All analyses were done by one counter who participates successfully in the American Industrial Hygiene Association's Proficiency Analytical Testing quality assurance program. Concentrations were calculated from the actual number of fibers counted (even it fewer than 50 fibers were counted) per the formulas in the NIOSH aethod.
DUP 0907330
DU 028431
-5NIOSH aethod P&CAM 239 reports a coefficient of
variation of 0.12 which applies to lapel samples in till
study. We estiaate that the coefficient of vaciation for the
in-sastc samples is 0.4 at the median in-facepiece concentration and fiber count (Table III).
SAMPLING AND ANALYSISMETHOD VERIFICATION
In-aask sampling required use of closed-face filter
cassettes. The Glasscock #1S0S 2Saa filter cassettes used have
a unique tapered design for the outlet and a half inch extender
which iapeoves the deposition pattirns^S}. To ainiaize
saaple loss, the NIOSH*5* probe was used to withdraw in-aask
saaples.
''
To eliainate possible bias, the %aae
closed-face/probed cassette was used for both in-aask and lapel saaples. To doeuaent whether concentrations deterained from closed-face/probe cassette sampling differed froa open-face
saapling. twelve area saaples were taken using both methods.
Results are coapared in Table 11 with Student's and Variance
Ratio tests. The two saapling aethods were found to give
siailac results with no significant bias or difference in
precision.
RESULTS AND PHCMSIQM Transmission electron microscopic analyses were aade
on four lapel saaples to document the distribution of fiber
disasters and lengths. Distributions are shown in Figures 1
and 2. Fiber disasters and lengths covered a vide range.
DUP 0907331
DU 028432
6 The overall aedian concentrations of fibers for in-nak and lapel saaples art given in Table III. The aedian numbar of fibars countad for in-aask (500 fialda couacad) and lapal (100 fiald countad) aaaplaa ara also given in Tabla III. Cuaulative distributions, gaoaatric aaans. gaoactric standard daviations. bast astimatss of 5th pareantilas and lists of vorkplaca protaetion factors ara givan in Figures 3 tbrougn for aaen raspirator. Tha distributions of vorkplaca protaction factors vara found to ba approxiaately lognoraal for all respirators studied. Therefor*, logs vara used for the plots, gaoaatric aaans ara reported.as the proper aeasnre of central tandancy and gaoaatric standard deviations ara reported as the proper aaasura of variability, left astiaatas of Stb _ pareantilas represent the vorkplaca protection factors that most (95%) raspirator users ara expected to obtain froa each raspirator. Distribution plots and gaoaatric standard daviations include variability froa tha saapling and analytical aethod as vail as froa tha vorkplaca protection factors. Tha unavoidable inclusion of tha saapling and analytical variability in tha plots results in bast astiaatas of 5th parcantila protection factors vhieh ara conservative (lover than aetual). This should ba considered in evaluating results.
DUP 0907332
DU 028433
-7Workplace protaction factors vara determined for a salf-contained breathing apparatus for two individuals. Results are reported in Table IV. Table V gives geometric means and standard deviations for all respirators studied. A Bonferroni(9} test for differences (pO.OS) was done and results are given in Table v. workplace protection factors for the 3K 9910 were found to be significantly higher than those for the AO B1050. No other significant differences were found. The relatively lov results for the AO RIOSO are likely due to poorer filter efficiency for asbestos, reported by Or. Ortiz of Los Alamos National Laboratory.^ `The unexpected ~ comparability of the results from the 3M disposable respirators, and elastomeric facepiece respirators with both dust, mist and funs filters and high efficiency filters may be explained by several factors. First, the limiting faetor in performance with the respirators is likely face fit. not filter efficiency (exeept tor the AO RIOSO as noted above). Since the seme fit test was used to select good fitting respirators for the study, comparable results would be expeeted. In addition, the researchers noted a tendency tor elastomeric respirators to slip around when some wearers' faces became wet with the water/surfaetant spray. This did not occur with the disposable respirators because their fibrous material of construction clung to the skin.
DUP O907333
DU 028434
-8It is particularly noteworthy that the vorJcplaca protaction factors for tha self-contained breathing apparatus wara not suparior to tha battar disposable and elastoaerie raspirators. Myhre^2* and Ravan(3^ hava shown that at workloads exceeding approximately 35% of aaxinal aarobic capacity prassura insida tha faeapiaca of pressure-deaand type respirators doas not raaain positive with respect to the surrounding ataosphece. This would provide an opportunity for asbestos to be drawn into tha facepiece. Tha volunteers who wort the self-contained breathing apparatus eoaplained of stress and diseoafort due to its weight and bulk. Moveaent and balance ware difficult and one
volunteer alnost fell from a step ladder ams a result. Based on their observations, the researchers believe that routine use of self-contained breathing apparatus for asbestos reaoval in the chemical industry would likely result in injuries, in view of the large aaount of eliabing involved. Certainly, acceptance will be such poorer than for the other respirators studied, due to discomfort which would discourage respirator use.
Transaission electron aieroscopie analyses were done on in-aask and lapel saaples. Resultant workplace protection factors are reported in Table VI. Results for saall disaster fibers (<0.2ua - the disaster below which fibers cannot be resolved with the standard optical aieroscopie aethod) do not appear to differ froa those for large disaster (&0.2ua) fibers, for S ua or longer lengths. Thus, results tor fibers visible
DUR 0907334
DU 028435
9 with tha phasa contrast aathod (>0.2ua diaaatar) appaar to b reprsssntativa of thosa for saallar diaaatar fibars for tha 3K 8710 and 9910. and for alastoaarie raspirators with a dust, fuaa and aist filtars and high afficiancy filtars.
DUP 09073 DU 028436
10 CONCLUSIONS
1. All respirators tested provided protection against
aabeitos. Tbe Aaeriean optical E1050 disposable respirator
reliably provided workplace protection factors of 5 or
greater. Tbe 3M 9910. 3M 1710. and elastoaeric half-face
respirators vitb both dust, fuae and aist and bigb
efficiency filters reliable provided workplace protection
factors of 10 or greater.
2. Use of higher efficiency filters did not appear to iaprove
tbe workplace protector factors of the elastoaerie
respirators.
3. Workplace protection factor measurements for a pressure
demand self-contained breathing apparatus ware not
_
significantly higher than those for the better disposable and elastoaeric respirators. Consents from the test
volunteers and observations indicate that acceptance of tbe
self-contained breathing apparatus will be poorer than that
of the other respirators tested. In addition, they present
a significant risk of tripping or falling where removal
work requires climbing ladders and working from scaffolding.
4. Transmission electron aicroscopic analyses indicate that
overall workplace penetration of small diaaeter (<2ua)
fibers (longer than 5 ua) is not discernibly higher than
that of larger diameter fibers for the 3M 1710 and 3M 9910
disposable respirators nor for elastomeric respirators with
dust, fuae and aist or high efficiency filters.
DUP 0907336
DU 028437
BiMifell*jjwm j]
LLi.2L:alMfii^
Hi !!
- 11 REFERENCES 1. Ortiz. L. W. et al: "Interim Report: Penetration of Respirator Filter* by an Asbestos Aetoeol." May 2. 1984 (Los Alamo* National Laboratory). 2. Myhre, L. 0.. R. D. Holden. F. N. Baumgardner and D. Tucker: Physiological Liaits of Firefighter*. Unclassified Report #ESL-TI-79-04, AFESC. Tyndall AFB. Florida (June 1979). 3. Raven. P. B. et al.: "Physiological Response to 'Pressure-Demand' Respirator Hear". Aa. Ind. Hyg. Assoc. J. 43 (10): 773-781 (1982). 4. "Quids to Respirator Fit Testing" (1981). National Paint and Coating Association. Washington. D.C. 5. Liu. B. Y. U. st al: "In-Mask Aerosol-Sampling for Powere4 Air Purifying Respirators." Aa. Ind. -Hyg. Assoc. J. 45(4):278-283 (1914). 6. U.S. Department of Healtn. Education and Welfare: MIOSH Manual of Analytical Methods. Second Edition. Voluae I (April 1*77). 7. National Institute tor Occupational Safety and Health. Method 7400. February IS. 1984.
.8 Adams. H. J. et al. "Cassette Extenders: Effects on
Chrysotile Fiber Deposition and Concentration Measurements". Presented at the American Industrial Conference. May 24. 1*83. 9. Snedecor. 0. M. and H. Q. Cochran: Statistical Methods. 7th Ed.. Iowa State University Press. Ames. Iowa (19*0).
DUP 0907337
DU 028438
tpirator Nam* Survivair 2000
Comfo II
3M 8710 3M 9910 American Optical R10S0 North 7700 Scott Air-Pak
TftBLS ,1. Respirators Studied
TVP*
Elastomeric (silicon* rubber) with dust, turn* and mist and high efficiency filters
Elastomer neoprene) with dust, fuc* and mist and high efficiency filters
Disposable with nonadjustabl* straps
Disposable with adjustable straps
Disposable with nonadjustabl* straps
Elastomerie (silicon* rubber) with high efficiency filters
Self-contained breathing apparatus, pressure-demand
Vendor U.S.D. Corp.
Min* Safety Appliance Co.
3M Company
3M Company
Aaerican Optical Company North Company
Scott AViation
DOS 0907338 DU 028439
TaBLS II
COMPARISON OF ASBESTOS SAMPLING METHODS LQEEN.rFACS VERSUS CLOSED-rXCE WITH PROBE!
Main
Pacaneter
Standard Daviation
T Statistic* Varianca Ratio** Data Open-face eassatta:
Closad-faea eassatta:
-vmt
2.2 ibers/aL - opaa aea filter eassatta 2.3 ibers/aL - closad aea eassatta vita probe 0.264 fibers/aL - open face eassatta 0.216 fibers/aL - closed aes eassatta with
probe
1.21
1.17
1.9. 1.9, 2.0, 2.1, 2.1, 2.1, 2.2, 2.2, 2,2, 2.2. 2.3, 2.9
2.0, 2.0, 2;0, 2.2, 2*.3, 2.3, 2.3, 2*^ 2.4, 2.4. 2.5, 3.0
* 1.21 is lass than a eoaparison t statistic o 1.71 (p0.0S). Therefore, the aaaas do aot differ significantly.
i.i7 is lass tbaa a eoaparison F statistic of 2.as (p0.0S). Therefore, tha variances (praeision) of the nathods do not differ significantly.
OOP 0907339 DU 028440
MEDIAN ASBESTOS CONCENTRATIONS AND COUNTS FOR WORKPLACE PROTECTION FACTOR STUDY FOR ___________ALL RESPIRATORS COMBINED
Concentrations Inside Respirator
Outside Respirator
0.006 fibsrs/aL (1 H8. TWA ~ 0.003)*
2.6 fibers/BL (S KB. TWA ~ 1.3)*
Counts
Inside Filter Outside Filter
9 fibers 130 fibers
no nor* taan Soar of eight work hour* were spent doing asbestos removal. Therefore, a factor of o.5 (4 HRS/e HRS) was applied to concentrations to estiaate HI TWA concentrations.
DUP 0907340 DU 028441
IBWMteiate (i
!i:
*iti y- r r
imijx WORKPLACE PROTECTION FACTORS FOR SELF-CONTAINED BREATHING APPARATUS fPRESSURg-DEMAMn)
WocKplaca Protaction Factor*: 400 880
Gtoaatric Maan: 820
Du* 0907341 DU 028442
IftBlS.v COMPARISON Of WORKPLACE PROTECTION ACTORS FOB SEVEN RESPIRATOR
Respirator__
Number of Measurements
Workplace Protection rector
Geometric Mean (Geom. S.D.)
Significant Differences
Lover Sth Percentile
3M 8710 3M 9910
18 310 (5.3)
20
14
580 (4.2)
Higher than
ss
R 10S0
American Optical RlOSO
Elastonerie/Dust, Pune and Miat Filter
7 17
S2 (4.2) 240 (4.3)
Lover than 3K 9910
5 12
Elastoaerie/High Efficiency Filter
14
94 (3.0)
16
North 7700 High Efficiency Filter
Self-Contained Breathing Apparatus Pressure-Demand
14 2
250 (4.9) 420
11 --
sited ea e Boaferroni test^*) at a 0.05 level of significance, only the 3M 9*10 and AO RlOSO differed.
DUp 0907342 DU 028443
TABLE VI
WORKPLACE PROTECTION FACTORS EB-QM- TRANSMISSION ELECTRQN__M_I.CR0S COj?.IC,,ANALY 5ES
Workplace Prottctic>a_Pi_ctac
Fibsrs Exceeding 0.2 ua
All Disaster Fibers gxcfdlnoJLua Length
3M 8710 3M 9910
330 47
120 41
Survivair 2000 with Oust. Mist and Fuat Filtor
28
29
Survivair 2000 with High Efficiency Filtoc
21
. 19
* Those which would bo counted by tho standard phase contrast aicroseopy aothod.
DUP 0907343 DU 028444
Figure 3 - Workplace Protection Factors for 3M 8710 Respirator
Cumulative Distribution: (Lognormal)
Geometric Mean: 310
Geometric Standard Deviation: 5.3 Best Estimate of 5th Percentile: 20
DU* 0907344
Data: 7.4,15, 61,110,110,180, 200, 310, 400, 420, 430,1000, 1000,1100,1500,1600,1800, 3200
DU 028445
Figure 4 - Workplace Protection Factors for 3M 9910 Respirator
Cumulative Distribution: (Lognormal)
Geometric Mean: 580
Geometric Standard Deviation: 4.2
DUP 0907345
Best Estimate of 5th Percentile: 55
Data: 94,110,150,150, 170, 280, 550, 630, 710, 1300, 2400, 3000, 3700, 5600
DU 028446
Figure 5 - Workplace Protection Factors for AO R1050 Respirator
Cumulative Distribution: (Lognormai)
Geometric Mean: 52
Geometric Standard Deviation: 42
Best Estimate of 5th Percentile: 5 Data: 9.7, 26, 28,38, 52,75, 970
0907346
DU 028447
< -- --os gd 3) "o>H r - o
Figure 6 - Workplace Protection Factors for Survivair 2000 and MSA Comfo Halfmask Respirators with Dust, Fume and Mist Filters
Cumulative Distribution: (Lognormal)
Geometric Standard Deviation: 6.3 Best Estimate of 5th Percentile: 12 Data: 15, 24, 45, 46, 47, 74, 88,140, 190, 370, 480,1000,1100,
1100, 1800, 4100, 4200
DU 028448
emit..
:-2;teigilfeigi! tttgl!
Figure 7 - Workplace Protection Factors for Survivair 2000 and MSA Comfo Halfmask
Respirators with High Efficiency Filters
Cumulative Distribution: (Lognormal)
Geometric Mean: 94
WPP
Geometric Standard Deviation: 3.0 Best Estimate of 5th Percentile: 16
DU* 0907348
Data: 12, 28, 32, 42, 65, 85,110,120, 140,160,160, 220, 220,
780, 7900*
* Removed from plot analysis, as an outlwr.
DU 028449
Figure 8 - Workplace Protection Factors for North 7700 Halfmask Respirators with High Efficiency Filters
Cumulative Distribution: (Lognormal)
< >OQ. CC CO CD -- - J -- H
Geometric Mean: 250
Geometric Standard Deviation: 6.9
Best Estimate of 5th Percentile: 11
Data: 12, 20, 36, 60, 74,110, 260, 350, 400,1000,1900.
2000, 2400, 3100
DUP 0907349
DU 028450