CHAPTER 11 224 Table 2. Infiltration Through Windows Expre,sed in Cubic Feel per Foot of Crack per Bout' ------------- VIWind elocitt, Milesper Hour Ttpe op Window Remarks | Around frame in masonry wall--not calked*1... , Around frame in masonry wall--calked ..____ j Around frame in wood frame construction1*........... Total for average window, non-weather-stripped, ----- u ifei-in. clearance.0 Includes I Double-Hung Wood Sash Windows (Un locked) 10 15 20 25 30 1 ------1- 8 14 20 27 - 52 6 3 11 4 17 6 23 30* 21 13 39 24 59 36 80 104 >-s 49 63 ' 69 19 111 34 154 51 199 71 249'; % Double-Hung Metal Windows* Rolled Section Steel Sash Windows* Non-weatherstripped, locked...... Non-weatherstripped, unlocked. Weatheratripped, unlocked................ ?....................... .Industrial pivoted, He-in. crack*--. ...................... 52 Architectural projected, H?-in. crack?..................... 15 Architectural projected, H4-in. crack..................... 1 90 Residential casement, Mi-in. crack'............ ........... RHeesaivdyenctaiasel mcaesnetmseenctti,oMn,sp-irno.jeccratecdk,1.H....i.-.i_n. crack1. Heavy casement section, projected, H*-in. crack1 45 47 19 70 96 125 154 ' 74 104 137 170 32 | 46 60 76 176 62 244 86 304 112 372 139, 52 18 32 10 a5 116 152 18233 47 60 74** 52 76 100 128 18 26 36 48; 24 38 54 Hollow Metal, vertically pivoted window*.................................... ............... 88 145 186 221 243 * The values gi ven in this table, with the exception of those for double-hung and hoilow. metal window are 20 percent less than test values to allow for building up of pressure in rooms, and are based on test dsti, reported in the papers listed in chapter footnotes. rTtehdeivnatlhueespgaivpeernsfrloisrt`fer-an--m-in-ecleuankpaAgcei are oper--fcoxot of` sas*h peri--me*t--er, -as ^d<e*tWermmmineedd ffoorr ddoouubbllee--hhuunnggwwooodl **'T--he v0a~lu--e-sAgfivtheon ffonrimfreamleeakleaagkeaignemaraesopnerryrowoatllust omrbigUinate.s..in the brick wall itself, and cannot beprif windows. Some of the frame leakage in masonry wall"s o`--rigi2n-a--tes* rtprfftFrtlv and deteriorates with tuns, viteinatceodnbsiydecraeldkiandgv. iFsaobrltehteoacdhodoitsioenthael rmeaassoonntrhy afrtacmaelklienagkaisgneovtanluoensefoprtsc^aclk^<* frames as the average dete min"eTdhbeyftiht eofctahlekeadvearnadgenodno-ucballek-ehduntegswtso. od window was determined as H-in. crack and clearance by measurements on approximately 600 windows under heating season conditions. > A The values riven are the totals for the window opening per foot of eash perimeter, and include frame leakage and so-called elsewhere leakage. The frame leakage values included are for wood frame construction, but apply as well to masonry construction assuming a 50 percent efficiency of frame calking. *1 WAiAnd-oinw.sctreasctkeadnind cplleaacreainncebrueilpdriensge,nstoatphoaot rnlyo friettdeudcwtioinndforowm, mteuscthvpaoluoerseristhnaenceasvsearrayg, ea.s mentioned u> * Industrial pivoted window generally used in industrial buildings. Ventilators boriaontally pivoted footnote a. at c*enAtrecrhoirtesclitguhratllylyapbroovjec, tleodwmerapdearotfsswaimngeisnegcotiount.s as industrial pivoted, except that outside framing meio* ber is heavier, and it has refinements in weathering and hardware. Used in semi-monumental building such as schools. Ventilators swing in or out and are balanced on side arms. Ha-in. crack iaobtainableiow* best practice of manufacture and installation, Mi-in. crack considered to represent average practice. * Of same design and section shapes as so-called heavy section casement, but of lighterweight. H4-in. crack is obtainable in the best practice of manufacture and installation, Ms-in- crack considered torepresentaveraS* practice. -f>; 1 Made of heavy sections. Ventilators swing in or out.and stay set at any degree of opening. H4-in. os? isobt&inable in the best practice of manufacture and installation, Ms-in. crack considered torepresentaversi* practice. Known as Intermediate Windows by steel window manufacturers. .^ k With reasonable care in installation, leakage at contacts where windows are attached to steel fra^*r work and at mullions, is negligible. With crack, representing poor installation, leakage at co&ti with steel framework is about one third, and at mullions, about one-sixth of that given for industrialpivot? windows in the table. The amount of infiltration for various types of windows is given in Tali2.2 The fit of double-hung wood windows is determined by crack and ctwleeaeranncthee. . inCsriadeek wthinicdkonwesfsraims eeqduimivaelnesniot ntoanodneth-healof uthtseidedifsfearsehncweidthThe difference between th'e width of the window frame guide and the sash thickness is considered as the clearance. The length of the perimet# opening or crack for a double-hung window is equal to three times the widfA plus two times the height, or in other words, it is the outer sash perimetef leneth. dIus the meeting rail length. All of the window crack in any g>V?? Infiltration and Ventilation 225 room is not necessarily used in estimating the infiltration heat loss by the crack method. The length of crack to be selected in any given case de pends on the number of exposed sides, as explained in Chapter 12. Values of leakage shown in Table 2 for the average double-hung wood window were determined by using, on nine windows tested in the labora tory, the average measured crack and clearance of a large number of windows found in a field survey. In addition, the table gives figures for a poorly fitted window. All of the figures for double-hung wood windows are for the unlocked condition. Just how a window is closed, or fits when it is closed, has considerable influence on the leakage. The leakage will be high if the sash are short, if the meeting rail members are warped, or if the frame and sash are not fitted squarely to each other. It is possible to have a window with approximately the average crack and clearance that will have a leakage at least double that of the figures shown. Values for the average double-hung wood window in Table 2 are considered to be easily obtainable figures, provided the workmanship on the window is good. Should it be known that the windows under consideration are poorly fitted, the larger leakage values should be used. Locking a window generally decreases its leakage, but in some cases may push the meeting rail members apart and increase the leakage. On windows with large clearances, locking will usually reduce the leakage. Wood casement windows may be assumed to have the same unit leakage -as for the average double-hung wood window when properly fitted. Lock ing, a normal operation in the closing of this type of window, maintains the crack at a low value. For metal pivoted sash, the length of crack is the total perimeter of the movable or ventilating sections. Frame leakage on steel windows may be neglected when they are properly grouted with cement mortar into brick work or concrete. When they are not properly sealed, the linear feet of sash section in contact with steel work at mullions should be figured at 25 percent of the values given in Table 2 for industrial pivoted windows. When storm sash are applied to well fitted windows, some reduction in infiltration is secured; the application of the sash provides an air space which reduces the heat transmission and helps prevent the frosting of the win dows.3 By applying storm sash to poorly fitted windows, a reduction in leakage of 50 percent may be obtained, the effect, so far as air leakage is concerned, being roughly equivalent to that obtained by the installation of weatherstrips. Door Leakage Doors vary greatly in fit because of their large size and tendency to warp. w-e^ door, the leakage values for a poorly fitted double-hung window may be used. If poorly fitted, twice this figure should be sed. If weatherstripped, the values may be reduced one-half. A single oor which is frequently opened, as might be the case in a store, should ~\ve a value applied which is three times that for a well fitted door. This *wa allowance is for opening and closing losses, and is kept from being Sreater by the fact that doors are not used as much in the coldest and windi est weather. mat*16 `D^ration rate through swinging and revolving doors is generally a tier of judgment by the engineer making cooling load determinations, jg ln the absence of adequate research data, the values given in Table 3 P esent current engineering practice. Some tests of infiltration through Pfpng and revolving doors have been reported.4. The data in Table 3