Document dQNwbKVM4wrkGZej2EbYK6xK9
Monsanto
FROM (NAME & LOCATIONl
Brawley - Krummrich
March 29, 1972
.u.JlCT .
REFERENCE
'
FINAL REPORT ON AROCLOR EMISSION INVESTIGATION
'
TO Mr. G. L. Bratsch
C. F. Buckley J. K. Grant P. E. Heisler A. E. Leisy R. M. McCutchan G. McRaven (246) D. J. Schillinger
Chairman
The five "Specific Recommendations" that were made by the investigating committee have all been completed.
1. Recommendation: Alter the vent valve (XV 508-4) to close on electrical failure.
Completed on 5/24 by Al Eversman (instrument Shop).
2. Recommendation: Install "open-close" switch for vent
^valve (XV 508-4) in the control room so operator can
accuate when needed.
Completed on 5/24 by Al Eversman (Elec. Shop); tested on same day.
5. Recommendation: Write specific procedure to be followed by operator when failure occurs.
Completed on 5/24 by V. Brawley (Dept. 246).
n,4.
Recommendation: Install alarm in control room on city water
make-up pump that supplies column tempered water circulating
system.
.
\
Completed on 5/24 by Al Eversman (Elec. Shop).
5. Recommendation: Check and reset alarm and Interlock on vent cooler outlet (TJR 1A-500).
Completed on 5/21 by Al Eversman (instrument Shop).
V. Brawley bp
STLCOPCB4066544
OFFICE SERVICES PRINT REQUEST (For Offset Duplicating)
Date
No* of Copies
One slide^ only
Front to back
Paper Stock Bond Flimsy Other
n
3-hole punched
Medium-run multilith
Run master from master Destroy
No* of masters
Ink Color Black Red Blue
1 I Green
Paper Color
I j White
1 V Blue 1 | Yellow
1 1 Pink
1 | Green
Please make copies and distribute to "Supervisory Mailing List".
Thank you.
PRINTS NEEDED BY:_____________ AUTHORIZED BY:_________;________ NAME: Teddi Marshalek, TSD
oS>N 296632
STLCOPCB4066545
EMISSION INVESTIGATION
Date of Incident:
March 8, 1972 4:00 A.M. and 6:00 A.M.
Location:
Dept. 246, Distillation Column
Kind of Emission:
Aroclor
Result of Emission:
Sprayed Aroclors in cone shaped pattern Southeast of column to points at least 100 yards from column. No complaints received.
Cause of Emission:
Loss of cooling on column condenser resulting from:
4:00 A.M. Incident - Electrical failure
6:00 A.M. Incident - City water make-up pump not started after electri
. cal failure.
No means available to isolate vacuum Jet to stop emission once it starts when power is off.
Investigating Committee:
Virgil Brawley Clarrie Buckley Jim Grant Gerald McRaven Ed Stewart, Chairman
DSW 296633
STLCOPCB4066546
THE INCIDENT: An electrical insulation failure and resultant power failure occurred at a condulet fitting in the 8-3 feeder which supplies part of the electrical power for Department 246. The incident happened about 4:00 A.M. on 3/8/72. The power supply to the 1016 Aroclor distillation area, the control room instrument panel, the city water make-up pump and the #2 still area were affected.
At the time of the electrical failure, Gerald McRaven proceeded to the #2 Still area where he performed the required emergency shut-down duties, cutting fires on the furnace and draining Aroclor from the furnace coils.
The power was restored about 4:45 A.M. and "Mac" proceeded to bring his equipment back on line. The #2 Still was first brought on line, and then the furnace was restarted and the distillation column heat up was started. "Mac" noted the tempered water circulating pump was hotter than normal and internal noises were present in the water circulating pump. The water and vapor temperatures from the vent cooler continued to increase. The vapor temperature is normally about 70C and above 100C will trigger an interlock that cuts fires on the furnace to remove heat input to the column. This event occurred. However, residual heat in the column resulted in con tinued boiling in the column.
A Department 248 operator called and informed the department of Aroclor droplets and sprays coming from the column. "Mac" proceeded to manually shut off a valve in the vapor line between the vent cooler and the jet; thus, stopping the emission.
The distillation column was brought back on line on the day shift of 3/8. It was discovered by Virgil Brawley that the city water make-up pump was not on. This pump is normally running all the time and supplies cold water to the column tempered water circu lating pump. Another similar power failure occurred at 10:45 P.M. on 3/8 and the power was shut off for repairs at 10:00 A.M. on 3/9/72.
oSVJ2966'4
STLCOPCB4066547
DISCUSSION
The emission was caused by a loss of cooling water at the column condenser. There will be a continued generation of vapors after the external source of heat has been discontinued because the column itself is a heat sink, and when refluxing stops there will be a further decrease in pressure which will promote boiling. Without cooling water on the condenser some vapors will pass uncondensed through the condenser, the vent" cooler, the jets and into the atmos phere. Although there is a valve in the vent line it currently fails in the open position on electrical failure, and there is no way to immediately stop the vapors during an electrical failure. See sketch.
On 3/8 and 3/9 there were four emissions:
1st 4:00 A.M. 2 6:00 A.M.
3 10:45 P.M. 4 10:00 A.M.
3/8 3/8
3/8 3/9
Power failure Start-up without cold make-up water Power failure
Shutdown for electrical repairs.
1st - Theenission related to the 4;00 A.M. power failure was probably less severe than the 6:00 A.M. failure. With the power off, there was no cooling water circulating and vapors passed to the atmosphere. No complaints were received. No records are available because the power supplied instrument records did not function during the power failure.
2nd - The 6:00 A.M. incident was probably the most severe. After the 4:00 A.M. incident, the column was started not knowing the city water make-up pump was not running. This pump stopped on the 4:00 A.M. Incident but was not started. It is in remote location from the column and is adjacent to two other pumps that were not affected.
It is believed that after the first power failure all the water in the tempered water loop drained from the loop, and during this attempted start-up very little water was present.
However, the power was on and the interlock functioned as
design to cut the fires. The emission was btopped by the operator when he shut the valve in the vent line to the atmosphere after receiving a call from neighboring department.
3rd - A second power failure occurred at 10:45 P.M. An emission was possible but no complaints were received. The same reason caused the power failure, a fault at the Insulation in one phase of the 8-3 feeder.
4th - A planned shutdown was made on 3/9 to make electrical
repairs. This happened during the investigation and an
emission occurred. Aroclor droplets were blown to the Northwest.
The emissions can be stopped by closing the valve between the vert cooler and the Jet. This can be done with minor electrical changes to permit the valve to fail in the closed position on electrical
failure. This can be done safely.and was reviewed with Dale Schillinger and Walter Howard of CED.
DSW 296635
STLCOPCB4066548
SPECIFIC RECOMMENDATIONS
1. Alter the vent valve (XV 308-4) to close on electrical failure. (TSD & Maintenance EDC 4/1/72)
2. Install "open-close" switch for vent valve (XV 308-4) in the
control room so operator can accuate when needed. To be inter
locked with the furnace such that when closed the fires will
be out.
"
(TSD & Maintenance EDC 4/1/72)
3. Write specific procedure to be followed by operator when power failure occurs. Include nitrogen addition at Still Pot to reduce pressure.
(Production EDC 4/1/72)
4. Install alarm in control room on city water make-up pump that supplies column tempered water circulating system. (TSD & Maintenance EDC 4/1/72)
3. Check and reset alarm and interlock on vent cooler outlet (TJR 1A-300) (Production EDC 4/1/72)
dSNN 296636
STLCOPCB4066549