J. G. Bryant
Persons Contacted: ^r. Lewis Gagnet and Don Long
Purpose of trip:
Test various drum coating applications in an effort to reduce the extremely high costs of dalbon. Fabricate test containers for in transit besting.
Background:
Various containers have been tested over the past year. The present standard (double coated phenolic) has too poor of an impact resistance. The most successful candidiate was double coated dalbon lined drums. As expected, the cost of the lining is about three and one half times the cost of the present liner. We believe, we may be able to flush the drums and arrive at the same quality with a cheaper alternate.
Summary:
Twenty one test drums using various applications of epoxy phenolic lining were fabricated. Ten dalbon drums were fabricated. However, excessive baking tempera tures burned the lining to the point of being unacceptable for testing. New dalbon lined drums baked at a lower temperature will be fabricated for testing.
Details;
The two problems needing attention in containers are the impact resistance and the cost of application. The present liner (phenolic) is the cheapest but, has the least impact resistance.
To test the least expensive alternate to phenolic, we made up five single coat epoxy phenolic. The surface of these drums "fish eyes" or has concave bubbles which yield bare spots (or at best minute coverage of the metal). To correct this problem five double coat drums were fabricated. The impact resistance (according to the lacquer manufacturer) is improved. With crude testing (ball hammer), X can see no difference between the clear epoxy phenolic and the clear phenolic.
The next least expensive alternate is the pigmented epqxy phenolic. The pigment
is suspose to add impact resistance to the epoxy phenolic and yield improved
adherence to the metal. Five drums with one coat of the pigmented epoxy phenolic
were fabricated. The surface on these drums was very smooth and may have contained
a few pin holes in the surface. Five double coat drums were fabricated for testing.
The impact resistance, by my test was slightly better than clear phenolic but,
no:great improvement.
.
The third alternate is to use only one coat of the dablon lining. Five of the
dalbon lined drums with one coat and five with the double coat were fabricated.
These units were over baked and ruined. All of them are being redone and baked
at a lower temperature.
SW 375289
STLCOPCB4099058
-3-
Discussibn: The dalbon liner is in a class of its own with an impact resistance which cannot be matched by any other liner. The crude tests with a ball hammer dent in the drum does not even crack the liner. We found the baking temperature for the liner is a critical factor in the impact resistance of the coating. For the drums baked at too high of a temperature (575C), we achieved a brittle coating with a flat black finish. The impact resistance was less than normally achieved with dalbon baked at the correct temperature (475C). Even the overbaked dablons impact resistance was considerably better than the epoxy phenolic. Dalbon cured at the proper temperature has a black glossy finish. Since two coat dalbon has proved successful, we feel with one coat we could obtain abput the same performance at one half the costs. Additionally, we found that impregnation of the drums with porocel will be slightly more difficult to control than anticipated. There are a number of alternates we can test for adding porocel to the drums once we find what the lining will do. The big problem is, anything we do approaches the cost of a single coat dalbon drum We feel that an Aroclor flush on a single coat of dalbon lining will probably clean the surface sufficiently. Without the lining cracking, there would be no reason for the quality to degrade. Plans for an automatic drum flushing technique are being developed. To test the effectiveness of the flushing and the various linings, the drums will be manually flushed with high quality Aroclor, filled, and shipped to New York and returned. The quality will be monitored before and upon return. Arrangements have been made with Toby White of Marketing and the tests should begin within the next two weeks. A comparison of the drums is shown on the attached table.
:jw Attachment
SW 375290
STLCOPCB4099059
DRUM COSTS
Type Container Hot Dipped Galvanized 18 gauge
16 gauge Present Double Coated Clear Phenolic Dalbon (Double Coat) Dalbon (Single Coat) Epoxy Phenolic (Pigmented-Double Coat)
(Pigmented-Single Coat) Epoxy Phenolic (Double Coat)
(Single Coat)
Costs
$13.53 $15.03
$ 8.05
$11.90
$ 9.40
$ 8.35 $ 7.70
$ 8.05 $ 7.55
r SW 375291 STLCOPCB4099060