BUSINESS CONFIDENTIAL Preliminary Information Sabjoct la latar verification or revision INFORMAL REPORT Pro|oct Mo.: 347K10 Data: August 21, 1967 AathoKs): j w Fields VINYL RESINS GENERAL, METAL CONTENT OF SELECTED RESINS Samples of suspension poly(vinyl chloride) resins from Pechiney-St. Gobain (Lucovyl GB-1210) and of the Leavyn fiber )J[reportedly made from crystalline poly(vinyl chloride both contain an unexpectedly high percentage of iron, aluminum, silicon and magnesium compared to the QYTQ-7 resin. The Pechiney-St. Gobain resin was found to be unsuitable in an earlier critical wire evaluation at Bound Brook. The samples evaluated include the following: (a) QYTQ-1, Blend 193, a UCC PVC homopolymer produced in production autoclaves at Texas City by the suspension process. (b) Lucovyl GB-1210, a PVC homopolymer produced by PechineySt. Gobain of France by a new bulk process. (c) Leavyn fiber, produced in Italy reportedly from PVC homopolymer; sample was obtained from American Viscose. Mr. H. J. Pazinski of the Bound Brook Laboratory has reported the Pechiney-St. Gobain resin to be unsuitable for critical electrical applications due to the low volume resistivity (letter dated April 7, 1966). The unfavorable electrical proper ties may be due in part to the high content of iron, aluminum, silicon and magnesium present in the resin. The metals analyses were obtained using emission spectroscopy at the South Charleston Plant Laboratory. The high tin content of the Leavyn fiber may be due to the presence of a stabilizer used in fiber manufacture. s Attachment: Table I ll/` ;/ Distribution Supervisor: Dr. J. J. Brezinski Assistant Director: Dr. F. E. Bailey, Director: Mr. J. J. Smith Mr. W. H. Bauer, TNY Dr. G. M. Bryant, 511 Mr. A. J. Costantin, 312 Mr. N. A. Gimber, 515 Mr. G. G. Himmler, 312 Mr. J. L. Hockersmith, 515 Jr. Mr. H. J. Pazinski, 312 Mr. D, E. Richardson, 515 Mr. T. R. Smith, 515 Mr. A. T. Walter, Mr. R. N. Wheeler Librarian, TNY Information Retrieval Author (2) Rosoorch and Dovolopmont Dopartmont Chemicals and Plastics Union Carbido Corporation UCC 042295 BUSINESS CONFIDENTIAL 347K10 TABLE I METAL ANALYSIS, PPM QYTQ-7 Blend-193 Pechiney-St. Gobain GB-1210 Leavyn Fiber Iron Chromium 2 30 2 <1 10 <1 Nickle Aluminum <1 3 2 27 <1 Too strong * to read Copper <1 <1 5 Tin <1 <1 20 Lead <1 <1 <1 Silicon 1 Too strong * Too strong * to read to read Magnesium <1 Too strong * Too strong * to read to read Samples were analyzed for metals content using emission spectroscopy at the South Charleston Plant Laboratory. * Estimated at >100 ppm. ucc 042296