Document dN88RjYpGg6KO1w6DpMyGZYe
County of Santa Clara California
Haaitn Oeeartmem
2220 mootu'i <nu San joaa. Ciiiromu 95128 297-1836 Area Coat *08
May 11, 1973
Mr. Dana Fralser
.
Safety Supervisor
Westlnghouse Electric Corp.
Heady Avenue
Sunnyvale, Calif. 96086
Dear Mr. Praiser:
|( COWIPBXTUI. |i
I ` ~ "_____J ^
On April 10, 1973, at your request, personnel from the Division of Occupational Health collected air samples for the presence of asbestos fibers from operations Involving grinding and sanding of phenolic composition containing asbestos.
Operator breathing tone samples were collected using a personal air sampling pump with a membrane filter having a pore sIts of 0.8 microns. Air was drawn through the filter at Che rate of 2.0 liters per minute. Personnel performing the work were provided with cartridge type respirecors and face shields, and the work was performed Inside an enclosed paint spray booth having water curtain to contain the particulates generated during the grinding and sanding operations. The filters were sent to the California Division of Industrial Safety for fiber counting. The results are as follows:
Asbestos Study, Westlnghouse Electric Corp. April 10* 1973
Sample Humber
Work Operation
Asbestos fibers
T.L.V.*
per cubic centimeter flbers/cc
1. Disc grinding
3.1 5.0
2. Hand-held oscillating sender
13.6
5.0
. * TLV flbers/cc - Threshold Limit Value for asbestos fibers established by the American Conference of Governmental Industrial Hygienists for an 8-hr. exposure; also allowable con centration under OSHAct and California General Industry Safety Orders.
The concentration of fibers produced by both the operations exceeds the celling or short time concentrations permitted under the OSHAct and the California GISO of 10 flbers/cc. The present practice of performing
An Equal Opportunity Employer
SOURCE 23
1400043;
55016946 0152744
SC-ELEC-05680
Mr. Dairna Fraiser May 11. 1973 Page 2.
CONFIDENTIAL
che operations in Che enclosed paint spray booch vich Che personnel wearing approved respiracors should be continued. In addition, recommendation is made that the engineering controls stated in Che Emergency Regulation on Asbestos. Article 110, March 1973, amendment to che General Industry Safety Orders, Section 5208 (b), dealing with local exhaust ventilation system on hand`operated power cools be instituted. A copy of the Emergency Regulation is enclosed.
This division is pleased to be of assistance to you in making this evaluation. Should there be any questions or if there is need for further help, do not hesitate to contact us.
Sincerely,
MK/ee
M. Koltetsu, M.P.H. Occupational He'alth Consultant
Enclosure.
SOURCE 236
140004~u 55016947
0152^45