Document dDxBqB8x9Xa7O44roRRG8QdNG

Monsanto r.n. 0*1 l TO gQjjj DreXler _ VIGK March 1, 1971 c Infrared Analysis of Aroclor 1242 R. Blowers H. Horner R. Munch - So. 2nd R. McCutcheon Ron Kuster Differential IR analyses were performed on a number of shipments of electrical grade Aroclor 1242 to General Electric Co. Two areas of absorption reported by G.E, on two samples were observed on all the samples checked. The significance of these peaks In regard to electrical properties Is not known to us, however, it should be noted that they do represent some difference in quality as compared to the reference material, KM-488 (7-1-70), MONX 8610. Relative Absorbance ^ Shipment 7.47 u 8.53 i KA-4o8, KA-412, KA-4l4, KA-418, KA-419, KA-4J0, MONX 86l8, MONX 8605, MONX 8604, MONX 8605, MONX 8624, MONX 8606, 1-18-71 1-24-71 1-28-71 2-6-71 2-10-71 2-25-71 (2) (2) .052 .020 .041 .019 .029 .045 .024 .017 .042 .024 .028 .046 1) Cell path length = 0.105 mm 2) Confirms G.E. report Sam Drexler, AR&D 019*890 TOWOLDMONOQ57234