Document dDq2X58D73RRa7w214nxBGzp5
MAr
Inspection Entry Date/Time Inspection Exit Date/Time Regulatory Program Type of Inspection
EPA REGION 7 Enforcement Division INSPECTION REPORT
03/11/2025 09:05 AM (CT)
Announced: No
03/11/2025 04:15 PM (CT)
Access: Granted
RCRA
Compliance Evaluation Inspection (CEI)
Company Name Facility or Site Name Facility/Site Identifier Facility/Site Physical Address City, State, Zip Code County/Borough Generator Status NAICS Type of Operation Geographic Coordinates
Profile Cabinet Profile Cabinet MOD985813021 7400 E 12th St Kansas City, MO 64126-2368 Jackson Small Quantity Generator (SQG) 33711, 33712 Cabinet Manufacturer and Granite Countertop Manufacturer 39.10244, -94.49459
Permit Number (If Applicable) Not Applicable
Additional Persons Participating in Inspection:
Name
Title
Organization
Mike Martin
Inspector EPA REGION 7
Mark Urbanek
Environmental MoDNR Unit Chief - Land Unit
Email
Phone
martin.mike@epa.gov
(913) 551-7149
mark.urbanek@dnr.mo.gov (816) 251-0706
Lead Inspector: Donald Melton
Digitally signed by DONALD
DONALD MELTON MELTON
[Signature]
Date: 2025.04.04 08:04:14 -05'00'
EPA REGION 7
Melton.Donald@epa.gov
[Date] (913) 551-5021
Supervisor Review: Amber Whisnant
AMBER [Signature] WHISNANT
Digitally signed by AMBER WHISNANT Date: 2025.04.04 12:49:07 -05'00'
[Date]
EPA REGION 7
whisnant.amber@epa.gov
SECTION I - INTRODUCTION Site Entry and Purpose of the Inspection Type of inspection: CEI
1 of 25
Profile Cabinet
Inspection Date(s):
MAr
03/11/2025 - 03/11/2025
At the request of the Enforcement Compliance and Assurance Division, I conducted an unannounced Resource Conservation and Recovery Act (RCRA) CEI at the Profile Cabinet (the "Site" or "Facility"), located at 7400 E 12th St, Kansas City, MO 64126-2368, at 9:05 AM (CT) on 03/11/2025. A drive-by of the facility was conducted prior to entering the building. No areas of concern were noted. Mr. Martin, Mr. Urbanek, and I entered the building's office, and I introduced myself to the office staff and requested to see Mr. Ken Wright who is listed as the site contact. Mr. Wright introduced himself and I provided my credentials to Mr. Wright, Mr. Curt Fish, and Mr. Jason Alsbury. I informed Mr. Wright that this was an EPA Region 7 inspection to determine compliance with RCRA. The CEI was conducted under the authority of Section 3007(a) of RCRA, as amended. I collected the information and data necessary to determine compliance with the applicable regulatory and statutory requirements. The inspection report and attachments present the results of the CEI. In addition, information gathered prior or subsequent to the Inspection from a review of USEPA, State, and public records may be included in this report.
The CEI consisted of a discussion of facility operations, waste generation, and waste management; a review of waste management records; and a visual inspection of waste generation and management areas. Document photocopies and photographs were collected as inspection documentation (Appendixes 1 and 2). A total of 18 photographs were collected and a photolog was prepared (Appendix 1). I followed the inspection procedures discussed in the RCRA CEI Standard Operating Procedure (No. 2321.1E), unless noted differently. Any authorized Federal regulatory citations noted in this report are adopted by reference in the authorized Missouri regulations.
Profile Cabinet was last inspected by Missouri Department of Natural Resources (MoDNR) on July 18, 2019. During the MoDNR inspection, 25 findings were cited.
1. B4 Failure to keep a container of holding hazardous waste closed during storage, except when it is necessary to add or remove waste. 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(a)(1) referencing 40 CFR 265.173(a).
2. B11 Failure to clearly mark and have visible for inspection on each container, the date of accumulation. 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(d)(4) referencing 40 CFR 262.34(a)(2).
3. B12 Failure to clearly label or mark containers "Hazardous Waste." 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(d)(4) referencing 40 CFR 262.34(a)(3).
4. B13A. Failure to label containers used to accumulate hazardous waste in accordance with applicable US DOT labeling requirements in 49 CFR part 172 subpart E during the entire time the waste is stored on site. 10 CSR 25-5.262(2)(C)1.A.
5. C.a.6. Failure to mark satellite accumulation containers of hazardous waste with either the words "Hazardous Waste" or with other words identifying the contents. 10 CSR 25-5.262(2)(C)3 incorporating 40 CFR 262.34(c)(1)(ii).
6. D9. Failure to attempt to make arrangements with police, fire department and emergency response teams. 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(a)(4) referencing 40 CFR 265.37(a)(1)
7. D12. Failure to attempt to make arrangements with local hospitals. 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(a)(4) referencing 40 CFR 265.37(a)(4).
8-17 Failure to create and maintain a personnel training plan including information as described in 40 CFR 265.15 18-25 Failure to maintain a contingency plan on site, which includes information as described in 40 CFR 265.52 and 40 CFR 265.53
Attendees
Title/Organization Name
Phone
Lead Inspector/EPA Donald Melton (913) 551-
REGION 7
5021
Email Melton.Donald@epa.gov
Opening Conf. Closing Conf.
Yes
Yes
2 of 25
Profile Cabinet
Inspection Date(s):
MAr
Inspector/EPA REGION 7
Mike Martin
Environmental Unit Mark Urbanek Chief - Land Unit/MoDNR
(913) 5517149
(816) 2510706
martin.mike@epa.gov
03/11/2025 - 03/11/2025
Yes
Yes
mark.urbanek@dnr.mo.gov Yes
Yes
Sr. Maintenance Ben Anthony (816) 231- bena@profilecabinet.com Yes
Yes
Technician/Profile
4601
Cabinet
Director of
Ken Price
(816) 231- kenp@profilecabinet.com Yes
Yes
operations/Profile
4601
Cabinet
Purchasing
Jason Alsbury (816) 231- jasona@profilecabinet.com Yes
No
Manager/Profile
4601
Cabinet
Manager/Profile Ken Wright (816) 231- kenw@profilecabinet.com Yes
No
Cabinet
4601
Finish Department Curt Fish
(816) 231- curtf@profilecabinet.com Yes
Yes
Supervisor/Profile
4601
Cabinet
Opening Conference
I explained the purpose and procedures of the inspection and presented Mr. Wright with a copy of RCRA Section 3007(a), which provides inspection authority. I explained my need to collect accurate information and presented a copy of Title 18 U.S. Code, Sections 1001 and 1002 regarding false statements and documents. I discussed Profile Cabinet confidentiality rights and informed Mr. Wright that a Confidentiality Notice would be provided at the end of the inspection to make a confidentiality claim, if desired.
I asked Mr. Fish and Mr. Alsbury to review the Notification Acknowledgement/Verification Report (Appendix 2 Attachment 1). According to the Notification Acknowledgement/Verification Report, Profile Cabinet operates as a SQG of characteristic (D001) and listed hazardous wastes (F003 and F005). The facility indicated that there were no changes to be made to the verification report. Based on my review of their monthly hazardous waste generation rate and manifest data, Profile Cabinet generates greater than 220 pounds but less than 2,200 pounds of hazardous waste per month and is therefore operating as an SQG. I determined Profile Cabinet to be a used oil generator and a used oil fuel marketer. See Process Description Section for discussion of their monthly hazardous waste generation.
Facility/Site Information
Number of employees 120
Length of Facility at Location
1988
Operating Hours
6:30 am - 5:00 pm Monday through Thursday and Fridays when needed
Safety Training Provided to Inspector(s)?
Not required
Size of Facility
220,000 sqft.
What type of
SQG
3 of 25
Profile Cabinet
Inspection Date(s):
MAr
generator facility notified?
What type of
SQG
generator facility
verified as?
03/11/2025 - 03/11/2025
Process Description
Profile Cabinet makes custom cabinets and granite countertops producing a monthly revenue of approximately $900,000 to $1,300,000. Profile Cabinet has a sales staff who will put in orders for cabinets or granite countertops. Once the facility starts the orders, the cabinets are manufactured in the Pro Line or Residential line and the countertops are manufactured in the Granite Department. Raw materials are delivered via the lumber dock door and placed in the raw material storage areas. The process takes place in steps from east side of the facility moving to the west side of the facility. Each department will use the raw materials to create the custom cabinets or countertops. In the cabinet product lines of the facility, the material is cut, sanded, assembled, painted or stained and shipped to be installed. In the Granite Department, the raw materials are delivered and measured, cut, cleaned and shipped. Based on uniform hazardous waste manifests, the average hazardous waste generation rate per month is approximately 450 to 950 pounds.
Messrs. Martin, Urbanek, and I conducted visual inspection of the following areas:
Building(s)
Building/Area/Sub-area
Process Description
Automotive
General maintenance, product storage, used oil storage
General dock
Ships and receives general items, ships general trash
Granite department
Measure, cut, sand, clean granite countertops
Lumber dock
Receive lumber, side entrance for facility
Maintenance room
Conduct facility maintenance as needed
Paint shop
Paint/Stain cabinets doors
Pro line
Manufactures cabinets/door for multifamily complexes
Residential Cabinets
Custom cabinets and doors
Office
howe
Documentation of arrangements with response agencies
Facility Waste Streams and Management
Area of Concern Yes
No
Yes Yes No Yes Yes
Yes Yes
Waste Description and Generation Process Paint waste
Waste Type HW
Generation Rate
~900 pounds per month
If HW, list all waste codes
Waste Determination Method
D001
Process knowledge
4 of 25
Waste amount Presently in Storage
~30 gallons
Oldest Accumulation Start Date
NA
Waste Disposal Location
Hazmat, Kansas City, MO
Profile Cabinet Inspection Date(s):
MAr
Paint filters HW
Used rags HW
Used Oil UO
~75-150 pounds per month ~150-300 pounds per month Varies
D001, F003, F005 D001
NA
Process knowledge SDS
NA
Lead-Acid EX Batteries (managed under 40 CFR 226 Subpart G) General SW Trash Waste Types AD = Analytical Data EX = Exempt HW = Hazardous Waste
Varies
NA
60 yards NA per week
ND = Not Determined SW = Solid Waste UW = Universal Waste
NA
NA UO = Used Oil
03/11/2025 - 03/11/2025
~100
NA
pounds
~60
NA
pounds
Hazmat, Kansas City, MO General trash
~60 gallons NA
NA
NA
Sent to Private Citizen to be burned in a space heater Batteries and bulbs, Liberty, MO
NA
NA
GFL Kansas City, MO
SECTION II - OBSERVATIONS
Building: Automotive Observation #: DM7-OB-001 Date: 03/11/2025 Person Interviewed: Ben Anthony
Contains AOC: Yes
Contains CBI: No
Title: Sr. Maintenance Technician
During the visual inspection, I observed two 55-gallon used oil storage drums, one used oil filter filled with oil, one used oil container with approximately two gallons of used oil in the container (photos 1, 2, and 3). The two 55-gallon drums were dented and appeared not to be in good condition Notice of Preliminary Finding (NOPF) 11: 10 CSR 25-11.279(1) incorporating 40 CFR 279.22(b)(1) Failure to use containers in good condition. The two 55-gallon drums were also not marked with the words "Used Oil." In addition, I observed one 2-gallon used oil collection container not marked with the words "Used Oil." NOPF 12: 10 CSR 25-11.279(1) incorporating 40 CFR 279.22(c)(1) - Failure to label the containers were not marked with the words "Used Oil." I observed a full used oil filter. I asked Mr. Ben Anthony what was the facility's management of used oil filters. Mr. Anthony stated that the used oil filter would be drained and the disposed of in the general trash. I asked Mr. Anthony if a hazardous waste determination had been conducted on the used oil filter. Mr. Anthony stated "No." NOPF 1: 10 CSR 25-5.262(1) incorporating 40 CFR 262.11 - Failure to conduct a hazardous waste determination. I informed Mr. Anthony that once the used filter is hot drained (in additon to puncturing, crushing or dismantling) it could be managed as scrap metal.
I observed three 5-gallon pails of old roof coating containers that have been accumulated for approximately two years (photo 4). The shipping label was dated in 2013. I asked Mr. Price if a hazardous waste determination had been conducted on the three 5-gallon pails of Tack Coat, Kool Seal, and Cool Elastic Primer. Mr. Price stated "No." NOPF 1: 10 CSR 25-5.262(1) incorporating 40 CFR 262.11 - Failure to conduct a hazardous waste determination. During the opening conference, Mr. Anthony said that the used oil is picked up by a private
5 of 25
Profile Cabinet Inspection Date(s):
MAr
03/11/2025 - 03/11/2025
citizen to burn in a space heater. I informed Mr. Anthony that the facility is operating as a used oil fuel marketer by sending the facility's used oil off-site to be burned in a private citizen's space heater. NOPF 13 a-h: 40 CFR 279 Subpart H 279.70-279.75 - Failure to comply with standards for used oil fuel marketers. The facility did not keep record on forms provided by the department on each shipment of used oil to a used oil burner, the facility shipped off-specification used oil to a burner that did not have an EPA identification number that burned used oil in an industrial furnace or boiler. The facility did not have any shipping records of the used oil that included name and address of transporter, name and address of the burner that will receive the used oil, EPA identification number of the transporter, shipping records that include the EPA identification number of the burner, quantity of used oil shipped or the date of the shipment.
NOPF 13 - Failure to comply with standards for used oil marketers
a. 10 CSR 25-11.279(2)(H) referencing 40 CFR 279.74 - Failure to keep records on forms provided by the department on each used oil shipment to a burner.
b. 10 CSR 25-11.279(1) incorporating 40 CFR 279.71 - Shipped off-specification used oil to a used oil burner without an EPA identification number that burns the used oil.
c. 10 CSR 25-11.279(1) incorporating 40 CFR 279.74(a)(1) - Did not have shipping records include name and address of the transporter that delivers the used oil to the burner.
d. 10 CSR 25-11.279(1) incorporating 40 CFR 279.74(a)(2) - Did not have shipping records include the name and address of the burner that will receive the use oil.
e. 10 CSR 25-11.279(1) incorporating 40 CFR 279.74(a)(3) - Did not have shipping records include the EPA identification number of the transporter that delivers the used oil to the burner.
f. 10 CSR 25-11.279(1) incorporating 40 CFR 279.74(a)(4) - Did not have shipping records that include the EPA identification number of the burner.
g. 10 CSR 25- 11.279(1) incorporating 40 CFR 279.74(a)(5) - Did not have shipping records that included the quantify of used oil shipped.
h. 10 CSR 25- 11.279(1) incorporating 40 CFR 279.74(a)(6) - Did not have shipping records that included the date of shipment.
Photo(s)
1. IMG-202503111009089886995.jpg 2. IMG-20250311101254125481505.jpg 3. IMG-2025031110160316373596.jpg 4. IMG-202503111020472047113730.jpg
Building: Lumber Dock
6 of 25
Profile Cabinet Inspection Date(s):
MAr
Observation #: DM7-OB-002 Date: 03/11/2025 Person Interviewed: Ben Anthony, Ken Wright
03/11/2025 - 03/11/2025
Contains AOC: Yes
Contains CBI: No
Title: : Sr. Maintenance Technician/ Director of Operations
I observed one 55-gallon drum of old roofing material. I asked Mr. Price and Mr. Anthony if a hazardous waste determination had been conducted on the drum. Mr. Price and Mr. Anthony both stated "No" (photo 5). NOPF 1: 10 CSR 25-5.262(1) incorporating 40 CFR 262.11 - Failure to conduct a hazardous waste determination. Mr. Anthony stated that the drum was from roofing repairs conducted from the building owner. Mr. Price and Mr. Anthony both stated that the facility will contact the building maintenance to conduct a hazardous waste determination on the 55-gallon drum of roofing material.
Photo(s) 1. IMG-20250311102909299138543.jpg
Building: Granite Department Observation #: DM7-OB-003 Date: 03/11/2025 Person Interviewed: Alex Wattson
Contains AOC: Yes
Contains CBI: No
Title: Granite Department Manager
I observed seven fluorescent bulbs in the Material Storage Room (photo 6). I asked Mr. Wattson if he know how long the fluorescent bulbs have been in the storage room. He stated approximately three years. I asked him if the fluorescent bulbs were product or waste. He stated that facility do not use those style of lights currently. I asked him if the facility could use the fluorescent bulbs in a different area on-site. He stated that he was not sure if the fluorescent bulbs would be used. I asked him if a hazardous waste determination had been conducted on the fluorescent bulbs. He stated "No." NOPF 1: 10 CSR 25-5.262(1) incorporating 40 CFR 262.11 Failure to conduct a hazardous waste determination.
Photo(s) 1. IMG-20250311103918391878597.jpg
Building: Pro Line
Observation #: DM7-OB-004 Date: 03/11/2025
Contains AOC: Yes
Contains CBI: No
Person Interviewed: Dave (last name not obtained)
Title: Pro Line Staff
In the Pro Line, staff will cut, sand, glue pieces of wood together, and assemble cabinets/doors. If there is any glue need to be wiped off the cabinets, rags used with mineral spirits would be used. Based on the review of the safety data sheet (SDS) of the mineral spirits, the waste rags contaminated with glue and mineral spirts would appear to exhibit the characteristic of ignitability (D001). The facility's solvent soaked rags are used until they are soiled or broken down, left out to dry, and then discarded in the general trash. At the time of inspection, no solvent-soaked rags were observed in used in the Pro Line. At the time of inspection Mr. Dave stated that in the past glue that was spilled or needed to be cleaned would be wiped up with rags with solvent and thrown in the general trash. Added 4/2/2025 upon further review a waste determination is needed on the rags that are used to clean up the glue NOPF 1: 10 CSR 25-5.262(1) incorporating 40 CFR 262.11 - Failure to conduct a hazardous waste determination. It appears that the glue Choice Adhesive to be a D001 (Appendix 2Attachment 5) hazardous waste and the solvent Mineral Spirits used to be a D001 (Appendix 2-Attachment 22) hazardous waste.
7 of 25
Profile Cabinet Inspection Date(s):
MAr
Building: Residental Cabinets Area Observation #: DM7-OB-005 Date: 03/11/2025 Person Interviewed: Ben Anthony, Ken Price
03/11/2025 - 03/11/2025
Contains AOC: No
Contains CBI: No
Title: Sr. Maintenance Technician/ Director of Operations
In this area, wood door and cabinet parts are sanded, cut, glued, painted, stained, and assembled. No concerns were noted in this area.
Building: Maintenance Room Observation #: DM7-OB-006 Date: 03/11/2025 Person Interviewed: Ben Anthony
Contains AOC: No
Contains CBI: No
Title: Sr. Maintenance Technician
Mr. Anthony escorted us to the Maintenance Room where I observed no concerns. The room held products and equipment needed to conduct facility maintenance tasks.
Building: Residental Cabinets Observation #: DM7-OB-007 Date: 03/11/2025 Person Interviewed: Ben Anthony
Contains AOC: Yes
Contains CBI: No
Title: Sr. Maintenance Technician
I asked Mr. Anthony about what would happen if the glue used in this area would spill or if it needed to be cleaned. He said that if it spilled, the staff would use rags to clean it up and let the rags dry before placing it in the general trash. Based on the review of SDS, the non-dry rags contaminated with waste glue would exhibit the characteristic of ignitability (D001). I did not observe any spills during the time of inspection. At the time of inspection Mr. Anthony stated that in the past glue that was spilled or needed to be cleaned would be wiped up with rags with solvent and thrown in the general trash. Added 4/2/2025 upon further review a waste determination is needed on the rags that are used to clean up the glue NOPF 1: 10 CSR 25-5.262(1) incorporating 40 CFR 262.11 - Failure to conduct a hazardous waste determination. It appears that the glue Choice Adhesive to be a D001 (Appendix 2-Attachment 5) hazardous waste and the solvent Mineral Spirits used to be a D001 (Appendix 2-Attachment 22) hazardous waste.
Building: Paint Shop Observation #: DM7-OB-008 Person Interviewed: Curt Fish
Date: 03/11/2025
Contains AOC: Yes
Contains CBI: No
Title: Finish Department Manager
In this area, I observed eight work benches with 55-gallon general trash drums. The solvents used in the facility are Barsol A-5208 and Mineral Spirits and solvent contaminated rags are disposed in the general trash. Based on the review of SDS, the solvent contaminated rags would exhibit the characteristic of ignitability (D001). I observed three 55-gallon general trash drums with solvent contaminated rags that were off gassing to dry (photos 9, 10 and 12-17). I observed that some of the solvent contaminated rags were damp to touch and may have contained free liquid. NOPF 2: Section 260.395 - Section 260.390.1(1) RSMo - Operated a hazardous waste facility without first obtaining a hazardous waste facility permit. I asked Mr. Fish if he knew the estimated monthly generation rate of solvent contaminated rags in the Paint Shop. He stated that approximately 150 pounds of rags are used in Paint Shop and 150 pounds of rags for the rest of the facility.
8 of 25
Profile Cabinet Inspection Date(s):
MAr
03/11/2025 - 03/11/2025
The facility has four paint booths with paint booth filters. The used paint booth filters are collected in two 1cubic yard gaylord boxes. Mr. Fish stated that the used paint booth filters are not contaminated with any solvents and are dry. He stated the used paint booth filters are managed as D001, F003 and F005 hazardous waste based on training from the previous Finish Department Manager. I observed two hazardous waste satellite containers of used paint booth filters (photo 11). One box was nearly full, and the other box was approximately full. It appeared that greater than 55-gallons of hazardous waste was exceed in the hazardous waste satellite area. NOPF 3: 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(c)(2) - Hazardous waste in excess 55 gallons stored in a satellite area. In additon, the hazardous waste satellite accumulation boxes of used paint booth filters were not labeled with the words "Hazardous Waste" (photo 11). NOPF 4: 10 CSR 255.262(1) incorporating 40 CFR 262.34(c)(1)(ii) - Hazardous waste satellite accumulation containers not marked either with the words "Hazardous Waste" or with other words identifying the contents. The area is checked more than once a week by staff.
Photo(s)
1. IMG-20250311111317131790379.jpg
2. IMG-202503111113301330101651.jpg
3. IMG-20250311111401141104051.jpg
4. IMG-20250311111607167116888.jpg
5. IMG-20250311113649364963208.jpg
6. IMG-202503111143474347108275.jpg
7. IMG-202503111143524352103026.jpg
Building: Paint Shop Observation #: DM7-OB-009 Date: 03/11/2025 Person Interviewed: Curt Fish and Shawn Laffler
Contains AOC: Yes
Contains CBI: No
Title: Finish Department Manager/Finish Department staff
I observed seven 5-gallon pails with dried paint and varnish that were dried solid (Photos 12-17). NOPF 1: 10 CSR 25- 5.262(1) incorporating 40 CFR 262.11 - Failure to make a waste determination. NOPF 2: Section 260.395 - Section 260.390.1(1) RSMo - Operated a hazardous waste facility without first obtaining a hazardous waste facility permit. According to Mr. Fish, the pails were a mixture of different bases, primers, catalysts, reducers, and varnishes with flash points below 140 degrees fahrenheit and there is one solvent 2butoxyethanol product code R6K25 (Appendix 2 - Attachment 21) that could be included in the mixture (with a flash point of 143.6 fahrenheit). From my review of the SDSs, the paint mixture would appear to exhibit the characteristic of ignitability (D001) at the point of generation. See attachments 5 to 22 for the complete list of SDS. Mr. Fish stated that the facility typically saves one SDS for each type of paint or item from the manufacturers. He stated that the information in the SDS does not change except for the color of paint or type of varnish. I asked Mr. Fish how many pails of dried paint mixture is generated per year. He stated approximately 12 pails throughout a year. The facility uses a large number of empty 5-gallon pails throughout the Paint Shop and the whole facility to collect rainwater from the leaking roof.
At the time of the inspection, there was no central accumulation containers onsite. Approximately every two weeks, the facility's hazardous waste is collected by Hazmat. The hazardous waste satellite accumulation area in the Paint Shop is near the point of generation and under the control of the operator. The area containing the satellite accumulation container of waste paint materials would be the central accumulation area and it is inspected weekly.
9 of 25
Profile Cabinet Inspection Date(s):
MAr
Below are the seven 5-gallon pails of dried paint mixture (photos 12-17): 1) Soft white 203. 1/5 full 2) H66 Kemvar 80 series conservation varnish. 3/5 full 3) Sher-wood Kemvar. 4/5 full 4) Canvar paint. 4/5 full 5) Canvar prime surface white. 1/2 full 6) Water white high performance water white conversion varnish. 1/5 full 7) Stone Enamel 206. 1/5 full
03/11/2025 - 03/11/2025
Photo(s) 1. IMG-20250311120342342118809.jpg
Building: Paint shop Observation #: DM7-OB-010 Person Interviewed: Curt Fish
Date: 03/11/2025
Contains AOC: Yes
Contains CBI: No
Title: Finish Department Manager
Overview of seven 5-gallon pails of dried paint mixture (described in observation DM7-OB-009). I asked Mr. Fish if the facility had conducted a hazardous waste determination on the pails of dried paint mixture. Mr. Fish stated "No." NOPF 1: 10 CSR 25- 5.262(1) incorporating 40 CFR 262.11 - Failure to make a waste determination. Based on my review of the SDSs, the paint mixture would appear to exhibit the characteristic of ignitability (D001) at the point of generation. The facility appears to be treating the hazardous waste by evaporation (intentionally letting the paint mixture evaporate/dry by means of open pails). NOPF 2: Section 260.395 - Section 260.390.1(1) RSMo - Operated a hazardous waste facility without first obtaining a hazardous waste facility permit.
Photo(s) 1. IMG-20250311115805585114923.jpg 2. IMG-202503111158215821104396.jpg 3. IMG-202503111158315831114477.jpg 4. IMG-202503111158385838115978.jpg
SECTION III - RECORDS REVIEW Record: Manifests and Land Disposal Restriction (LDR) Notices Ref #: DM7-RR-001 Reviewed By: Donald Melton
AOC: No Reviewed Date: 03/11/2025
I did not observe any areas of concern with the uniform hazardous waste manifests and LDR notices.
10 of 25
Profile Cabinet Inspection Date(s):
MAr
03/11/2025 - 03/11/2025
Building: Office Record: Documentation of arrangements with response agencies
AOC: Yes
Ref #: DM7-RR-002 Reviewed By: Donald Melton
Reviewed Date: 03/11/2025
During the visual inspection, I did not observe the emergency coordinator's name and phone number, the locations of emergency equipment, or the telephone number of the fire department posted next to a telephone Mr. Price said the facility did not have the emergency information posted (NOPFs 5, 6, and 7). I asked Mr. Price if the facility has made or attempted to make arrangements with emergency services or response agencies. Mr. Price stated they have not (NOPFs 8, 9, and 10). Mr. Anthony stated that in 2023 the fire department did come on site to do a walk through, and the facility did get a receipt of that walk through. However, Mr. Anthony stated they did not have documentation besides a payment receipt. Document was not requested due to payment details.
NOPFs 5-10:
5. 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(d)(5)(ii)(A) - Failure to post the emergency coordinator's name and phone number is posted next to the phone
6. 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(d)(5)(ii)(B) - Failure to post locations of fire extinguishers and spill control material, and if present, fire alarm, are posted next to the phone
7. 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(d)(5)(ii)(C) - Failure to post the telephone number of fire department is posted next to the phone
8. 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(d)(4) referencing 40 CFR 265.37(a)(1) - Failure to make arrangements with police, fire department and emergency response teams to familiarize them with the layout of the facility
9. 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(d)(4) referencing 40 CFR 265.37(a)(3) - Failure to attempt to make agreements with state emergency response teams, emergency response contractors and equipment suppliers
10. 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(d)(4) referencing 40 CFR 265.37(a)(4) - Failure to attempt to make arrangements to familiarize local hospitals with the properties of hazardous waste handled at the facility and types of injuries and illnesses that could result from fires, explosions or releases at the facility
SECTION IV - AREA OF CONCERN
The presentation of Area(s) of Concern does not constitute a formal compliance determination or violation.
Building: Automotive, Lumber Dock, Granite Department, Paint shop, Pro Line, Residental Cabinets DM7-OB-001, DM7-OB-002, DM7-OB-003, DM7-OB-010 NOPF 1: 10 CSR 25- 5.262(1) incorporating 40 CFR 262.11 - Failure to conduct a waste determination on one used oil filter (photo 3), three pails of roof coating (photo 4), one 55-gallon drum of roofing material (photo 5), seven fluorescent bulbs (photo 6), used rags in Paint Shop (photo 9-10), seven 5-gallon pails in Paint Shop (photo 12-17), waste glue rags.
Building: Paint Shop DM7-OB-008, DM7-OB-010 NOPF 2: Section 260.395 - Section 260.390.1(1) RSMo - Operated a hazardous waste facility without first obtaining a hazardous waste facility permit by (photos 9, 10 and 12-17).
11 of 25
Profile Cabinet Inspection Date(s):
MAr
Building: Paint Shop DM7-OB-008
03/11/2025 - 03/11/2025
NOPF 3: 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(c)(2) - Hazardous waste in excess 55 gallons (or 1 quart of acutely hazardous wastes) stored in a satellite area must, with respect to that amount of excess, go to storage or be shipped within three days and container holding the excess accumulation is marked with the date the excess amount began accumulating (Photo 11).
Building: Paint Shop DM7-OB-008
NOPF 4: 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(c)(1)(ii) - Two hazardous waste satellite containers of used paint booth filters not marked either with the words "Hazardous Waste" or with other words identifying the contents (Photo 11).
Building: Office DM7-RR-002
NOPF 5: 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(d)(5)(ii)(A) - Failure to post the emergency coordinator's name and phone number next to the phone.
Building: Office DM7-RR-002
NOPF 6: 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(d)(5)(ii)(B) - Failure to post the locations of fire extinguishers and spill control material, and if present, fire alarm, are posted next to the phone.
Building: Office DM7-RR-002
NOPF 7: 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(d)(5)(ii)(C) - Failure to post the telephone number of fire department is posted next to the phone.
Building: Office - Documentation of arrangements with response agencies DM7-RR-002 NOPF 8: 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(d)(4) referencing 40 CFR 265.37(a)(1) - Failure to make arrangements with police, fire department and emergency response teams to familiarize them with the layout of facility, properties of waste handled, associated hazards, places where facility personnel would normally be working, entrances to roads inside the facility and possible evacuation routes. Building: Office - Documentation of arrangements with response agencies DM7-RR-002 NOPF 9: 40 CFR 262.34(d)(4) referencing 40 CFR 265.37(a)(3) - Failure to make agreements with state emergency response teams, emergency response contractors and equipment suppliers. Building: Office - Documentation of arrangements with response agencies DM7-RR-002 NOPF 10: 10 CSR 25-5.262(1) incorporating 40 CFR 262.34(d)(4) referencing 40 CFR 265.37(a)(4) - Failure to make arrangements to familiarize local hospitals with the properties of hazardous waste handled at the facility
12 of 25
Profile Cabinet Inspection Date(s):
MAr
03/11/2025 - 03/11/2025
and types of injuries and illnesses that could result from fires, explosions or releases at the facility.
Building: Automotive
DM7-OB-002
NOPF 11: 10 CSR 25-11.279(1) incorporating 40 CFR 279.22(b)(1) - Failure to use containers in good condition dented oil containers (Photos 1-2).
Building: Automotive
DM7-OB-002
NOPF 12: 10 CSR 25-11.279(1) incorporating 40 CFR 279.22(c)(1) - Failure to label three used oil storage containers with the words "Used Oil" (Photos 1-3).
Building:
DM7-OB-001
NOPF 13 a-h: 40 CFR 279 Subpart H 279.70-279.75 - Failure to comply with standards for used oil marketers. The facility did not have any documentation on shipments from MoDNR for each shipment of used oil to a burner, did not ship used oil to a used oil burner that had an EPA identification number that burned used oil in an industrial furnace or boiler. The facility did not have any shipping records of the used oil that included name and address of transporter, name and address of the burner that will receive the used oil, EPA identification number of the transporter, shipping records that include the EPA identification number of the burner, quantity of used oil shipped or the date of the shipment
a. 10 CSR 25-11.279(2)(H) referencing 40 CFR 279.74 - Failure to keep forms provided by the department on each used oil shipment to a burner.
b. 10 CSR 25-11.279(1) incorporating 40 CFR 279.71 - Shipped off-specification used oil to a used oil burner without an EPA identification number that burns the used oil.
c. 10 CSR 25-11.279(1) incorporating 40 CFR 279.74(a)(1) - did not have shipping records include name and address of the transporter that delivers the used oil to the burner.
d. 10 CSR 25-11.279(1) incorporating 40 CFR 279.74(a)(2) - did not have shipping records include the name and address of the burner that will receive the used oil.
e. 10 CSR 25-11.279(1) incorporating 40 CFR 279.74(a)(3)- did not have shipping records include the EPA identification number of the transporter that delivers the used oil to the burner
f. 10 CSR 25-11.279(1) incorporating 40 CFR 279.74(a)(4) - did not have shipping records that include the EPA identification number of the burner.
g. 10 CSR 25- 11.279(1) incorporating 40 CFR 279.74(a)(5) - did not have shipping records that included the quantify of used oil shipped.
h. 10 CSR 25- 11.279(1) incorporating 40 CFR 279.74(a)(6) - did not have shipping records that included the date of shipment.
SECTION V - CLOSING CONFERENCE AND FOLLOW UP
13 of 25
Profile Cabinet Inspection Date(s):
MAr
Closing Conference
03/11/2025 - 03/11/2025
I summarized the findings and recommendations with Mr. Price. I provided Mr. Price with a Confidentiality Notice which he signed as acknowledgement of receipt (Appendix 2 - Attachment 4); Mr. Price made no confidentiality claims. I also provided Mr. Price with a Receipt for Documents and Samples and a NOPF, which Mr. Price signed as acknowledgement of receipt (Appendix 2 - Attachment 2) Mr. Price would like to be added to the list of people to copy on the inspection report.
The following compliance assistance documents were provided to the facility at the conclusion of the CEI: COMPLIANCE ASSISTANCE DOCUMENTS Hazardous waste generator status guidance pub2224 Hazardous waste satellite accumulation pub2215 The universal waste rule in Missouri pub2058 Aerosol cans pub1084
Follow Up No follow-up at this time CEI. Communication Log
14 of 25
Profile Cabinet
Inspection Date(s):
MAr
03/11/2025 - 03/11/2025
The following information received by Region 7 after exiting the facility on 03/11/2025.
Type Email
Point of Contact Ken Price
Email Phone call
Ken Price Ken Price
Email
Ken Price
Email
Ken Price
Phone call
Ken Price
Email
Ken Price
Job Title/Organization Director of Operations
Director of Operations Director of Operations
Director of Operations
Director of Operations
Director of Operations
Director of Operations
Description
Email to Mr. Price requesting Mineral Spirits SDS Email from Mr. Price Mineral Spirits SDS Phone call to Mr. Price left a message about NOPF response and addition NOPF about waste glue rags Email to Mr. Price NOPF response and addition NOPF about waste glue rags Email from Mr. Price regarding NOPF response requesting a call to discuss Phone call to Mr. Price and I left a message on the NOPF response Email from Mr. Price NOPF response
Contains PII No No No
No
No No No
Date 3/13/2025 3/17/2025 4/2/2025
4/2/2025
4/3/2025 4/3/2025 4/3/2025
SECTION VI - SAMPLING ACTIVITIES AND ANALYTICAL RESULTS No sampling was conducted.
SECTION VII - LIST OF APPENDICES 1. Photo Log 2. Report Attachments
15 of 25