October 4, 1967
Mr. Winn Morris Tenneco Manufacturing Company P. O. Box 349 fssadena, Taxes 77531 Dear Mr. Morris Our Mr. Tom White has asked me to forward toxicity informstin for our compressor lubricant Fydraul AC. A summary of the toxicity infomatlon tuay be stated as follows 1,
la salsa1 toxicity studies with fydraul AC. the oral lethal dose la rats is approximately 43 grass per kilogram and for rabbits, 3.5 to 4.5 grams per kilogram. The greater sensitivity of rabbits is typloal of this type of fluid. This lethal dose is of such an order, however, that the fluid may be considered only 'slightly toxlo" to raan from oral doses. The fluid may be absorbed through the unbroken skin of rabbits la doses resulting such that sealdental massive skin exposures to non de not present a hazard. Skin and ays irrita tion studies with rabbits classify the fluid as a mild irritant. Laboratory animals survived six-hour exposures to on atmosphere saturated with the vapors of the fluid. On the baaia of this data, it la con cluded that fsrdronl AC requires no special handling precaution* other than avoiding prolonged or repeated skin contact. Accidental splashing in the eyes will result la nodarately severe pain and irritation but no permanent damage should result. I an not sure whet your particular application nay la that ralaee the question of toxicity. We have run atxae rather United testa on a particular compressor whore the air downstream showed no detectable levels of the lubri cant nor any decomposition products. It must be pointed out. however, that there are many factors which could offset the
DSW 018753
STLCOPCB4005297
'!r. (inn Horria
-2- Oototer 4, l'jCj
amount, if any, of any lubricant In the compressed air. 3ome of these include the mechanicai condition of the compressor, temperature of compresaor cylinder walls, variationa in operation, etc. If there were any thermal decomposition, we would expect t) find HC1, CO, COo, phenols, aldehyde*, etc. depending on the degree of deoooqpoaition*
It appear* appropriate to ua that, regardless of the type of ubrleant, If the air la to be used for breathing purposes, a filter should be placed in the line to remove not only any possible lubricant, tut inolature, rust and any other possible contaminants.
If I can be of any further service, please do not hesitate to let me know*
Very truly yours.
R. onet Kelly, H.D. Medical Director