Document d661e2R1vDwb5VyKpYverXxQ

ClJi/'-o o/f PLAINTIFF'S EXHIBIT INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION i L CUBICAL CENT in P.Cj BOX n:'J61. SOUTH CHARLESTON. WV C53C13 To (Namel O'viS'on Loc;i.n Are3 L. R. Noble 725-1 Cooy to -- J. W. Barna W. L. Browning T. L. Collins P. D. Gossage P. L. Graham C. P. Maxwell M. L. Mills C. L. Ruddle R. E. Sergent OrUt O' -IJii iOL'w ' I O'.-pt Area Si ;o,ecr September 4, 1986 HS&EA Industrial Hygiene Respiratory Protection Program for Asbestos Insulators / This is to inform you that there are certain respiratory protection requirements established by OSHA in its amended standard for asbestos which may be significant with regards to administration of the respiratory protection program. As you know the amended permissible exposure limit for asbestos is 0.2 fiber per c.c. of air. For up to ten times this level (2 fibers/c.c.), it is acceptable to use a half-mask respirator equipped with HEPA filter. Between 2 and 10 fibers/c.c., a full face respirator equipped with HEPA filters is acceptable. Between 10 and 20 fibers/c.c., any powered air purifying respirator equipped with HEPA filter or any supplied-air respirator operated in continuous flow mode is acceptable. It should be noted that the fit tests must be provided to affected employees every six months and that the qualitative fit test is acceptable only for the half-mask air purifying respirator. The full face mask in a negative pressure mode requires quantitative fit test. It seems that a full face mask with HEPA filter would be a good choice based on our past monitoring data which shows that exposure conditions while stripping asbestos containing insulation at our location are well below 10 fibers/c.c. and in most instances, less than 2 fibers/c.c.. However, there could be a potential problem of training employees with a quantitative fit test which requires elaborate testing equipment. UCC 024136 Respiratory Protection - cont. -2- September 4, 1986 Based on all facts and assessment of the situation, I make the following recommendations: 1. At all jobs requiring stripping of asbestos containing insulation, where 1H monitoring is conducted, the employees should use a powered air purifying respirator equipped with HEPA filter. This will eliminate fit testing at 6 months interval. 2. At all jobs requiring stripping of asbestos containing insulation, where IH monitoring is not conducted, the employees must use supplied-air respirators operated in the positive pressure mode. Recommendation #2 is based on the OSHA requirement which, along with other requirements, will be discussed in a meeting to be held on September 12 in the large conference rooms. Construction Department at the Institute Plant. If you have any questions, please feel free to give me a call. MAP:rab 1683P Manhar A. Patel UCC 024137