UnitedStates Radiator Corporation
General Oiiices: Detroit, Michigan
Branches and Sales OUices in Principal Cities
Detroit, Michigan
Front Extended Jacket
Performance Curve
1
fHP 2*
--
' o nci NO
US iso
Output--% of Direct Standing Radiator Load Flue Gas Analysis CO2--12.5%; O2--4.1%; C0-0.0%.
CAPITOL THINTUBE RADIATORS
3-Tube
Height*
Per Section Heating Surface
19* 1.1 Sq Ft 22' 1.3 Sq Ft 25' 1.5 Sq Ft
CAPITOL FINCAST ENCLOSURES AND CONVECTORS
Made entirely of cast iron. Without joints--Cast in one piece. Many lengths and widths. Tappings, top, bottom and ends. Complete choice of enclosures. Finished to harmonize with modern
interiors.
CAPITOLAIRE DIRECT FIRED
4-Tube
19* 1.4SqFt 22' 1.6SqFt 25' 1.8Sq Ft
5-Tube
20' l.8SqFt 23' 2.1 SqFt 26* 2.4 Sq Ft
6-Tube
19" 1 2.2 Sq Ft . 32" 1 3.85 Sq Ft
40 per cent less space needed for these graceful, efficient Capitol ThinTube Radiators.
CONDITIONING UNIT
An air conditioning unit especially de signed for oil firing. Streamline flue con struction in preheating and prime-heating sections insures high efficiencies. Deluxe jacket completely encloses all controls, heating unit, automatic humidifier, filter and fan.
Other gravity and forced air furnaces available for gas, stoker or hand coal firing.
948
Boilers, Casl-Iron
United States Radiator Corporation
General Offices: Detroit. Michigan
Branches and Sales Oiiices in Principal Cities
Detroit, Michigan
CAPITOL RED CAP BOILERS
For All Fuels
CAPITOL SQUARE BOILERS FOR ALL FUELS
"A" Series
Ratingi in Sq Ft
Direct Cast Iron Radiator Loads--Sq Ft
Steam-- 575-1450 Water- 975-2475
280- 655 460-1085
"B" Series
Steam-1200-3600 Water--1980-5940
550-2030 910-3350
"C" Series
Steam--4700-10,500 I Water--7760-17,325 |
1865-5805 3080-9580
Direct Cast Iron
Boiler No.
Radiator Loads Sq Ft
Steam Water
19-4 300 19-5 350
495 580
20-4 20-5
400 450
660 745
22-4 22-5
500 550
825 910
25-4 25-5
625 675
1030 1115
Capitol Red Cap Boiler design brings the advantages oi (1) long fire trayeli (2)-flue passages that force the hot Raises to circulate through every sectsbti, "ex tracting the maximum heat from the fuel consumed. (3) Deep firepot that provides the extra space needed for better? com bustion, and smooth, tapered . ^firepot walls to assure a clean surface for better heat absorption.
CAPITOLAIRE CONDITIONING UNIT FOR SPLIT SYSTEMS
Illustrated above is a Capitol Red Top Series "C" Boiler. These sectional, cast iron, all fuel boilers can be furnished either
jacketed or unjacketed. Sections are con nected with precision-made slip nipples in
accurately machined ports and the in dividual sections are ground to permit an iron-to-iron gas-tight assembly. The large, smooth flueways are designed with out sharp turns reducing friction, per
mitting unrestricted gas travel. For easy cleaning, all flueways are fully accessible through the large front clean-out doors.*.
Controlled internal water circulation and
large nipple ports insure complete sepa ration of water and steam. Capitol Red Top Boilers are heavily insulated against
heat loss by a thick blanket of rock wool, reinforced with wire mesh to prevent slip ping or sagging. Capitol Red Top Boilers
can be furnished with extra high steel bases to provide extra setting height or desired
additional furnace volume for stoker firing. These bases eliminate the necessity for
pitting or building a brick or concrete base.
A suspended unit, quiet in operation, using ducts to convey heated, humidified and filtered air to various rooms of the home. Heating supplied to the Unit heat
exchange coil by a steam or hot water boiler. Floor model conditioning units with a wide range of heating capacities also
available.
SPECIFICATIONS
Capacity--BTU/HR
Unit No.
Heating*
200
21
H. W. Steam
Cooling**
50 40 Water Refrig.
Air Capacity
cfm
S-1 34,000 28,000 14.000 15.000
S-2 48,000 39,000 19.000 21.000 S-3 65,000 54,000 26.000 28.000 S-4 99,000 128.000 37.000 39.000
500 750 1000 1500
949 S'