The safety professional is required to make judgments on the degree of hazard associated with chemical exposures It is his duty, therefore, to obtain information on the fire and health hazards of these chemicals and use it to evaluate and, where necessary, con trol the exposures
This chapter tabulates the basic physical constants of many common industrial chem icals and lists relative health and fire hazards New chemicals are being introduced and new data on the properties of existing chemicals are constantly being published and revised For this reason, the safety professional should also consult the most up-to-date revisions of the references referred to for each chemical
Using the Table
Recognition
The material m this chapter can be used to determine the degree of fire and health hazards m using a new chemical For ex ample, the safety professional can compare evaporation rates, vapor volumes, and flash points and choose a solvent that combines the lowest volatility and fire and health haz ards consistent with process needs
Then too, this tabulation can serve as a means of gaming familiarity with the proper ties of chemicals--liquids, dusts, gases, vapors, and solids--encountered m the working en vironment
Evaluation
Also in this chapter is the fundamental information needed for a preliminary evalu ation of a chemical hazard The more com plex problems, however, require the services of an industrial hygienist
The following is an example m which the degree of health hazard resulting from a solvent exposure is to be evaluated using data from the table m this chapter and Table 38-E, "Threshold Limit Values for 1973," from Chapter 38, "Industrial Toxicology "
Trichloroethylene is being used in a metalfimshmg workroom 20 by 10 by 20 ft In an 8-hr workday, 5 gal of the solvent is lost through evaporation There are two air changes per hour Is there a potential health hazard?
1200
Solution- Assuming there is complete mix ing of the trichloroethylene throughout the workroom, then
Volume of room = 20 X 10 X 20 = 4000 cu ft
Total volume of air supplied to work room in 8 hr = 4000 cu ft X 8 hr X 2 changes/hr : 64,000 cu ft/8-hr day
Vapor volume = 36 cu ft/gal (from table)
Total vapor volume = 36 cu ft/gal X 5 gal = 180 cu ft
Threshold limit value of tnchloroethylene (from Table 38-E) = 100 ppm
Total volume of air required to dilute trichloroethylene to threshold limit _ 180 X 1,000,000
- KW = 1,800,000 cu ft/8-hr day
Therefore, since natural ventilation is sup plying only 64,000 cu ft of air per 8-hr day, there is a potential health hazard and addi tional ventilation is required to maintain the solvent concentration within safe limits
Note that this type of calculation is valid only if the air contaminant is uniformly dis tributed at a relatively low concentration Where the air contaminant is localized in high concentrations, such as in a paint-spraymg operation, more complex means of evalu ating the hazard must be used (See details in NSC's Fundamentals of Industrial Hygiene )
Control
Data from the table in this chapter can also be used to estimate the amount of exhaust ventilation needed to control an explosion hazard
Example An average of 1 gal of n-heptane per hour is being evaporated m a drying oven Estimate rate of exhaust ventilation needed to prevent an explosive concentration
Solution. Assuming complete mixing of the n-heptane throughout the oven, the rate of ventilation depends on the volume of evap-