Document byry6ZVZ0yGbKZm95r9ZnmXZ1

CUMULATIVE SUPPLEMENT TO JULY 1974 EDITION OF NIOSH CERTIFIED PERSONAL PROTECTIVE EQUIPMENT JANUARY 1975 |k/ V;'7*T U.S. DEPARTMENT OF HEALTH, EDUCATION, AND WELFARE Public Health Service Center for Disease Control. National Institute for Occupational Safety and Health Morgantown, West Virginia 26505 AS I 00022655 Single copies are available from: Office of -Technical Publications National Institute for Occupational Safety and Health Post Office Building Cincinnati, Ohio 45202 Please include a self-addressed mailing label to assist us. AS I 00022656 CONTENTS1 PREFACE I. COAL MINE DUST PERSONAL SAMPLER UNITS Approved Coal Mine Dust Personal Sampler Units Names and Addresses of Manufacturers Applicable Approval Regulations II. GAS DETECTOR TUBE UNITS Certified Detector Tube Units Names and Addresses of Manufacturers and Distributors Applicable Certification Regulations III. RESPIPATORY PROTECTIVE DEVICES Approved Respiratory Protective Devices Self-Contained Breathing Apparatus Gas Masks Supplied-Air Respirators Dust, Fume, and Mist Respirators Chemical-Cartridge Respirators Tables for Identification of Approved Component Parts Table III-l. Table II1-2. Table III-3. Table III-4. Table III-5. Self-Contained Breathing Apparatus Gas Masks Supplied-Air Respirators Dust, Fume, and Mist Respirators Chemical-Cartridge Respirators Pressure ranges and hose-length ranges for approved supplled-alr respirators. Names and Addresses of Manufacturers and Distributors Applicable Approval Regulations 1This table of contents lists all entries in the July 1974 edition and this supplement. Items marked with an asterisk appear in this y/.-rt'G r supplement. - AS I 00022657 PREFACE This cumulative supplement to the July 1974 publication, NIOSH CERTIFIED PERSONAL PROTECTIVE EQUIPMENT, lists approvals and certifications Issued between July 18, 1974, and January 24, 1975. A new table has been added, describing the pressure range and hose length range for each approved supplied-air respirator. Reprints of amendments to respirator approval regulations appear at the end of this supplement. These amendments postponed the effective date for expiration of Bureau of Mines respirator approvals and provided for approval of vinyl chloride respirators. Since NIOSH is not a major purchaser or user of Personal Protective Equipment, it welcomes Information from the user concerning NIOSH certified or approved equipment. These comments and suggestions, comments on this publication and requests for additional information on certified equipment can be sent to the Director, Testing and Certification Laboratory, National Institute for Occupational Safety and Health, 944 Chestnut Ridge Road, Morgantown, West Virginia 26505. ASI 00022658 X. COAL MINE DUST PERSONAL SAMPLER UNITS The following coal mine dust personal sampler unit has been approved by the U.S. Department of Health, Education, and Welfare, National Institute for Occupational Safety and Health, since July 18, 1974. 6. Bendix Model C-115. Approval TC-74-017, issued to Bendix Corp., September 17, 1974. II. GAS DETECTOR TUBE UNITS The following gas detector tube units have been approved by the National Institute for Occupational Safety and Health since July 18, 1974: A. MSA Model 83499 Universal Sampling Pump has been certified for use with 5. Nitrogen dioxide - Model 83099 gas detector tube, TC-84-040, October 29, 1974. 6. Chlorine - Model 460225 gas detector tube, TC-84-042, November 12, 1974. 7. Sulfur dioxide - Model 92623 gas detector tube, TC-84-046, January 15, 1975. B. Gastec Model 400 Aspirating Pump (Bendix PN 2417535) has been certified for use with 8. Trichloroethylene - Model 132H gas detector tube, TC-84-038, August 9, 1974. 9. Chlorine - Model 8La gas detector tube, TC-84-041, November 12, 1974. 10. Benzene - Model 121 gas detector tube, TC-84-043, December 6, 1974. C. Drager Bellows Pump Model 31 has been certified for use with 8. Trichloroethylene - Model CH 24401 (10/a) gas detector tube, TC-84-039, October 1, 1974. 9. Benzene - Model 67 26641 (5/b) gas detector tube, TC-84-044, December 6, 1974. AS I 00022659 Page 2 D. Kitagawa Model 400 Aspirating Pump (Matheson PN 8014-400) has been certified for use with 8. Hydrogen sulfide - Model 120b gas detector tube, TC-84-037, July 23, 1974. 9. Carbon monoxide - Model 100 gas detector tube, TC-84-045, January 15, 1975. III. RESPIRATORY PROTECTIVE DEVICES The following respiratory protective devices have been approved by the U.S. Department of the Interior, Mining Enforcement and Safety Administration, and the U.S. Department of Health, Education, and Welfare, National Institute for Occupational Safety and Health, since July 19, 1974. Self-Contained Breathing Apparatus 18. SurvivAir part numbers 9038-00, 9038-02, 9838-00, and 9838-02 demand-type one half hour compressed-air self-contained breathing apparatus. Approval TC-13F-44, issued to SurvivAir Div., U.S. Divers Co., August 30, 1974. 19. SurvivAir part numbers 9038-20, 9038-22, 9838-20, and 9838-22 pressure demand-type one-half hour compressed-air self-contained breathing apparatus. Approval TC-13F-45, issued to SurvivAir Div., U.S. Divers Co., August 30, 1974. 20. MSA part numbers 457150, 95061, 457151, and 95068 demand-type 15 minute compressed-air self-contained breathing apparatus. Approval TC-13F-46, Issued to Mine Safety Appliances Co., January 10, 1975. 21. MSA''"/ part numbers 95063 and 460262 pressure-demand type 15 minute compressed-air self-contained breathing apparatus. Approval TC-13F-47, issued to Mine Safety Appliances Co., January 10, 1975. Gas Masks 3. MSA part numbers 461481, 461482, 461483, 461484, 461485, and 461486 gas masks (with part number 461480 canister) for respiratory protection against vinyl chloride. Approval TC-14G-84, issued to Mine Safety Appliances Co., December 30, 1974. 4. Scott part numbers 601211-17 and 601221-17 gas masks (with part number 084-VCL canister) for respiratory protect! n against vinyl chloride. Approval TC-14G-85, issued to Scott Aviation, December 30, 1974 AS I 00022661 Page 3 5- Welsh part numbers 7820, 7820S, 7829, and 7829S gas masks (with part number 780O-2VC(TC-14G-91) canister) for respiratory protection against vinyl chloride. Approval TC-14G-91, issued to Welsh, A Textron Company, January 17, 1975. Supplied-Air Respirators 9. Scott catalog numbers 4616-11, -12, -15, -21, -22, and -25; and 4622-11, -12, -15, -21, -22, and -25 supplied-air respirators (Type C continuous-flow type) with 4266-15, 4265-25, and 4264-50 air supply hose. Approval TC-19C-71, issued to Scott Aviation, August 20, 1974. 10. Scott catalog numbers 4616-18, -19, -28, and -29; and 4622-18, -19, -28, and -29 supplied-air respirators (Type C continuous-flow type) with 4259-15, 4258-25, and 4257-50 air supply hose. Approval TC-19C-72, issued to Scott Aviation, August 20, 1974. 11. Scott part number 802230 supplied-air respirator (Type C demand and continuous flow type). Approval TC-19C-73, Issued to Scott Aviation, November 26, 1974. 12. Scott part number 801548 supplled-atr respirator (Type C pressuredemand type). Approval TC-19C-74, issued to Scott Ayiatlon, November 26, 1974. Dust, Fume, and Mist Respirators 16. A.O* R1050 single-use respirator for respiratory protection against pneumoconiosis and fibrosis-producing dusts. Approval TC-21C-147, Issued to American Optical Corp., August 14, 1974. 17. Safeline 5350 single-use respirator for respiratory protection against pneumoconiosis and fibrosis-producing duats. Approval TC-21C-148, Issued to Safeline Products, August 14, 1974. 18. Scott part numbers 662-1 and 662-2 respirators (with 502-R filter) for respiratory pr tectlon against dusts, fumes, and mists having a time-weighted average less than 0.05 mg/Mr, and radionuclides. Approval TC-21C-149, issued t Scott Aviation, August 20, 1974. AS I 0002266 Page 4 19. MSA^part numbers 88479 and 457117 respirators (with part number 88480 filter) for respiratory protection against dusts, fumes, and mists having a time-weighted average less than 0.05 mg/M3, and radionuclides. Approval TC-21C-150, issued to Mine Safety Appliances Co., September 9, 1974. /*"**>, 20. Welsh 7506 respirator (with 7500-6 filters) for respiratory protection against dusts and mists having a time-weighted average not less than 0.05 mg/M3 or 2 mppcf and asbestos-containing dusts and mists. Approval TC-21C- 151, issued to Welsh, A Textron Co., September 11, 1974. 21. Welsh 7580 respirator (with 7500-8 filters) for respiratory protection against dusts, fumes, and mists having a time-weighted average less than 0.05 mg/M3, and radionuclides. Approval TC-21C-152, issued to Welsh, A Textron Co., September 11, 1974. 22. Welsh 7406 L respirator (with 7400-6 filter) for respiratory protection against dusts and mists having a time-weighted average not less than 0.05 mg/MJ or 2 mppcf and asbestos-containing dusts and mists. Approval TC-21C-153, Issued to Welsh, A Textron Co., September 23, 1974. 23. Cover 1482 respirator (with F100 filters) for respiratory protection against dusts having a time-weighted average not less than 0,05 mg/M3 or 2 mppcf. Approval TC-21C-154, Issued to H. S. Cover Co., November 26, 1974. Chemical-Cartridge Respirators 21. A.O. R5052 respirator (with R52 cartridges) for respiratory protection against not more than 10 parts per million chlorine, 50 parts per million hydrogen chloride, and 50 parts per million sulfur dioxide. Approval TC-23C-60, issued to American Optical Corp., August 14, 1974. 22. A.O. R6052 respirator (with R52 cartridges) for respiratory protection against not more than 10 parts per million chlorine, 50 parts per million hydrogen chloride, and 50 parts per million sulfur dioxide. Approval TC-23C-61, issued to American Optical Corp., August 14, 1974. 23. Safeline 5221 respirator (with 5963 cartridges) for respiratory ,, protection against not more than 10 parts per million chlorine, 50 parts per million hydrogen chloride, and 50 parts per million sulfur dioxide. Approval TC-23C-62, issued to Safeline Products, August 14, 1974. 24. Welsh 7504 respirator (with 7500-4 cartridges) for respiratory protection against not more than 300 parts per million of ammonia. Approval TC-23C-63, issued to Welsh, A Textron Co,, September 11, 1974. 25. Welsh 7514 respirator (with 7500-4 cartridges and 7500-6 filters) f r respiratory prot ction against n t more than 300 parts per million of iiwnonia, dusts and mists having a time-weighted average not 1 ss than 0.05 mg/M-* r 2 mppcf, and asbestos-containing dusts and mists. Approval TC--23C--64, issued /' to Welsh, A Textron Co., September 11, 1974. ASI (>0022662 Page 5 26. Welsh 7303 respirator (with 7500-3 cartridges) for respiratory protection against not more than 1,000 parts per million organic vapors, 10 parts per million chlorine, 50 parts per million hydrogen chloride, or 50 parts per million sulfur dioxide. Approval TC-23C-65, issued to Welsh, A Textron Co., September 11, 1974. 27. Welsh 7313 respirator (with 7500-3 cartridges and 7500-6 filters) for respiratory protection against not more than 1,000 parts per million organic vapors, 10 parts per million chlorine, 50 parts per million hydrogen chloride, or 50 parts per million sulfur dioxide, dusts and mists having a time-weighted average not less than 0.05 mg/MJ or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-66, issued to Welsh, A Textron Co., September 11, 1974. 28. Willson 1222 respirator (with R22 cartridges) for respiratory protection against not more than 10 parts per million chlorine. Approval TC-23C-67, Issued to Willson Products Div., ESB Inc., September 11, 1974. 29. Willson 122210 respirator (with R22 cartridges and R10 filters) for respiratory protection against not more than 10 parts per million chlorine, dusts and mists having a time-weighted average not less than 0.05 mg/M^ or 2 rappcf, and asbestos-containing dusts and mists. Approval TC-23C-68, Issued to Willson Products Div., ESB Inc., September 11, 1974. 30. Willson 1223 respirator (with R23 cartridges) for respiratory protection against not more than 50 parts per million sulfur dioxide. Approval TC-23C-69, issued to Willson Products Div., ESB Inc., September 11, 1974. 31. Willson 1224 respirator (with R24 cartridges) for respiratory protection against not more than 300 parts per million ammonia or 100 parts per million methyl amine. Approval TC-23C-70, issued to Willson Products Div., ESB Inc., September 11, 1974. 32. Willson 122410 respirator (with R24 cartridges and R10 filters) for respiratory protection against not more than 300 parts per million ammonia, 100 parts per million methyl amine, dusts and mists having a time-weighted average not less than 0.05 mg/MJ or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-71, issued to Willson Products Div., ESB Inc., September 11, 1974. 33. Willson 122310 respirator (with R23 cartridges and R10 filters) for respiratory protection against not more than 50 parts per million sulfur dioxide, dusts and mists having a time-weighted average not less than 0.05 mg/M'* or 2 mppcf, and asbestos containing dusts and mists. Approval TC-23C-72, Issued to Willson Products Div., ESB Inc., September 11, 1974. 34. Welsh 7511 respirator (with 7500-1 cartridges and 7500-b filters) for respiratory protection against not more than 1,000 parts per million organic vapors, dusts and mists having a time-weighted average not leas than 0.05 mg/M3 or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-73, issued to Welsh, A Textron Co., September 11, 1974. AS I 00022663 Page 6 35. Welsh 7549 respirator (with 7500-21 cartridges and 7500-23 filters) for respiratory protection against pesticides. Approval TC-23C-74, issued to Welsh, A Textron Co., September 23, 1974. 36. Welsh 7531 respirator (with 7500-1 cartridges and 7500-10 filters) for respiratory protection against organic vapors and paint, lacquer, and enamel mists. Approval TC-23C-75, issued to Welsh, A Textron Co., September 23, 1974. 37. Willson 1225 respirator (with R25 cartridges) for respiratory protection against not more than 10 parts per million chlorine, 50 parts per million hydrogen chloride, or 50 parts per million sulfur dioxide. Approval TC-23C-76, issued to Willson Products Dlv., ESB Inc., September 30, 1974. 38. Willson 122510 respirator (with R25 cartridges and R10 filters) for respiratory protection against not more than 10 parts per million chlorine, 50 parts per million hydrogen chloride, or 50 parts per million sulfur dioxide^ dusts and mists having a time-weighted average not less than 0.05 mg/M or 2 mppcf, and asbestos-containing dusts and mists. Approval TC-23C-77, issued to Willson Products Div., ESB, Inc., September 30, 1974. 39. 3M W262 and W263 powered air purifying respirators (with W2031 filter and W2114 cartridge) for respiratory protection against pesticides. Approval TC-23C-78, issued to 3M Co., January 24, 1975. 40. MSA part number 448848 respirator (with part number 448847 cartridges) for respiratory protection against pesticides. Approval TC-23C79, Issued to Mine Safety Appliances Co., January 24, 1975. 41. MSA part number 448849 respirator (with part number 459315 cartridges and 448842 filters) for respiratory protection against organic vapors and paint, lacquer, and enamel mists. Approval TC-23C-80, issued to Mine Safety Appliances Co., January 24, 1975. c ASI 00022664 Page 7 TABLES FOR IDENTIFICATION OF APPROVED COMPONENT PARTS Table III-l. Self-contained breathing apparatus component parts, by approval number. Approval number Approval Issued to Respirator number(s) Component parts, number(s) and description TC-13F-44 SurvivAir Div., U.S. Divers Co. 9038-00, 9038-02, 9838-00, 9838-02, 9411-12 or 9413-20, facepiece. 9118-00, regulator. 9602-47, low-pressure warning. 9151-45, cylinder and valve assembly. 9457-00, back-pack assembly. TC-13F-45 SurvivAir Div., U.S. Divers Co. 9038-20, 9038-22, 9838-20, 9838-22 9411-60 or 9413-60, facepiece. 9118-01, regulator. 9602-47, low-pressure warning. 9151-45, cylinder and valve assembly. 9457-00, back-pack assembly. TC-13F-46 Mine Safety Appliances Co. 457150, 95061, 457151, 95068 96680 or 95940, facepiece. 96065, breathing tube assembly. 456104, cylinder and valve assembly. .... 456066, support assembly. 460255, regulator assembly. TC-13F-47 Mine Safety Appliances Co. 95063, 460262 96057, facepiece. 96065, breathing tube assembly. 456104, cylinder and valve assembly. 456066, support assembly. 460256, regulator assembly. AS I 00022665 Page 8 Table III-2. Gas masks component parts, by approval number. Approval number TC-14G-84 TC-14G-85 TC-14G-91 Approval issued to Mine Safety Appliances Co. Scott Aviation Welsh Respirator number(s) 461481, 461482, 461483, 461484, 461485, 461486. Component parts, number(s) and description 95940 or 96680, facepiece. 88306, 457168, or 457175, breathing tube assembly. 84937 or 84938, harness. 461480 canister. 601211-17, 601221-17 742, facepiece. 6108-10 or 6110-27, breathing tube assembly. 565 or 600309-00, harness. 084-VCL canister. 7820, 7820S, 7829, and 7829S 780011 or 780011S, facepiece. 780060 or 780061, hose assembly. 780039 or 780041, harness assembly. 780062, connector. 7800-2VC canister. ASI 00022666 Page 9 Irtl'lw III i. Pitjtji I I t*d I r venpirntors component parts, by approval number, A t< pv i h* a 1 UUIttiiK.t IV I'M ' \v \ *v -,i Appruvn1 Issued tv' Hn'il Av irt t ion Nvv t < v \ \ * i -isr. Respirator number(s) ** olb-ll, -i:, -15, "* * A ^ ^ And -25 4022-11, -12, -ii, *. i. ^ ^ ** -15 * s, *- -V- -anc, -7* **f22---If,, --5C --U; arur ~-2: Component parts, number(s) and description 742 or 4704, facepiece. 6119, breathing tube. 4196 or 4196-1, flov control valve and cartridge assembly, 4256, air-supply hose. 742 or 471)4, lacepiece, t~29,, breaming iube, 41*P or 419Sv~2* liojr -MmCcvv valve and naxrridgje mwmfcXy,* 4125,, air--supply itose.. `As `'!''NV" SiS'tt <'.>*,; i;v-. ffi.r 5f.. S0Q^3I*-*D/A1. djac^iewsc ISfrapAJiWlT'f 1 &P227-t# zx&QmSxkt J^GZl--01^03. .mgjgOgr 3*W & wam&z juunsixr ante *BOWe,^ So-,'.;; *'<*c-snr UOIStf '-S0J43MB<,., iSrnxrn0m^0mm0%X^ 6BiS4*~rOEU -taayiflart**-- - .2jrr~-m/, -maySiZv .'jnam ' 526121-111733,, jjmm-MiSi- -26225--01. x&ncmpjmac Asia; anar .303110230221 aprcifcK iflWicMa^ AS I 00022667 Table III-4. Dust, fume, and mist respirators component parts, by approval number. Approval number TC-21C-147 TC-21C-148 TC-21C-149 TC-21C-150 TC-21C-151 TC-21C-152 TC-21C-153 TC-21C-154 Approval issued to Respirator number(s) American Optical RIO50 Corp. Safeline Products 5350 Scott Aviation 662-1 and 662-2 Mine Safety Appliances Co. 88479 and 457117 Welsh 7506 Welsh Welsh 7580 7406L Cover 1482 Component parts, number(s) and description R1Q50, respirator assembly. 5350, respirator assembly. 805 or 742, facepiece. 502-R, filter. 96680 or 95940, facepiece. 88480, filter. 7500-30, facepiece assembly. 7500-6, filters. 7500-14, filter covers. 7500-30, facepiece assembly. 7500-8, filters. 7400-30, facepiece assembly, 7400-6, filter. 7400-14, filter cover. B222, respirator assembly. F100, filters. ASI 00022668 Page 11 Table XII-5. Chemical-cartridge respirators component parts, by approval number. Approval number Approval issued to Respirator number(s) Component parts, number(s) and description TC-23C-60 American Optical R5052 Corp. 50206, basic respirator subassembly. R52, cartridges. TC-23C-61 American Optical R6052 Corp. 51071, basic respirator subassembly. R52, cartridges. TC-23C-62 Safeline Products 5221 05862, basic respirator subassembly. 5963, cartridges. TC-23C-63 Welsh 7504 7500-30, facepiece assembly. 7500-4, cartridges. TC-23C-64 Welsh 7514 7500-30, facepiece assembly. 7500-4, cartridges. 7500-6, filters. 7500-14, filter covers. TC-23C-65 Welsh 7503 7500-30, facepiece assembly. 7500-3, cartridges. TC-23C-66 Welsh 7513 7500-30, facepiece assembly. 7500-3, cartridges. 7500-6, filters. 7500-14, filter covers. TC-23C-67 Willson 1222 AR700, basic respirator assembly. R22, cartridges. TC-23C-68 Willson 122210 AR700, basic resplrat r assembly. R22, cartridges. R10, filters. R682, filter retainers. TC-23C-69 Willson 1223 AR700, basic respirator assembly. R23, cartridges. AS I 00022669 Page 12 Table III-5. Chemical-cartridge respirators component parts, by approval number--Continued. Approval Approval numberissued to Respirator Component parts, number (s)number(s) and description TC-23C-70 Willson 1224 AR700, basic respirator assembly. R24, cartridges. TC-23C-71 Willson 122410 AR700, basic respirator assembly. R24, cartridges. RIO, filters. R682, filter retainers. TC-23C-72 Willson 122310 AR700, basic respirator assembly. R23, cartridges. RIO, filters. R682, filter retainers. TC-23C-73 Welsh 7511 7500-30, facepiece assembly. 7500-1, cartridges. 7500-6, filters. 7500-14, filter covers. TC-23C-74 Welsh TC-23C-75 Welsh 7549 7531 7500-30, facepiece assembly. 7500-21, cartridges. 7500-23, filters. 7500-14, filter covers. , ' . 7500-30, facepiece assembly. 7500-1, cartridges. 7500-10, filters. 7500-14, filter covers. TC-23C-76 Willson 1225 AR700, basic respirator assembly. R25, cartridges. TC-23C-77 Willson 122510 AR700, basic respirator assembly. R25, cartridges. R10, filters. R682 filter retainers. TC-23C-78 3H W262, W263 W2801, powered air purifier. W2031, filter. W2114, cartridge. W2090, breathing tube. W5005, helmet, or W5201 hood. AS I 00022670 Page 13 Table III-5. Chemical-cartridge respirators component parts, by approval number---Continued. Approval number Approval issued to Respirator number(s) Component parts, number(s) and description TC-23C-79 Kine Safety Appliances Co. 448848 449703, facepiece assembly 448847, cartridges. TC-23C-S0 Mine Safety Appliances Co. 448849 449703, facepiece assembly 459315, cartridges. 448842, filters. 448844, filter covers. if> - f ASI 00022671 Page 14 PRESSURE RANGES AND HOSE-LENGTH RANGES FOR APPROVED SUPPLIED-AIR RESPIRATORS Approval number Respirator(s) Hose-length range, feet TC-19C-64 Cesco PI-800 15 TC-19C-64 TC-19C-65 U.S. Safety Services PI-80 SurvivAir 9011-12, 9811-12 15 4 - 250 TC-19C-66 TC-19C-67 TC-19C-68 SurvivAir^ 9011-14, 9811^14 SurvivAir 9011-13, 9811-13 SurvivAir 9011-15, 9811-15 4 - 250 4 - 250 4 _ 250 TC-19C-69 3M W-810, W-840, W-856, W-858, W-870 25 - 300 TC-19C-70 3H W-820, W-880, W-881, W-888, W-890 25 - 100 TC-19C-71 TC-19C-72 Scott 4616-11, -12, -15, -21 -22, -25; and 4622-11, -12, -15, -21, -22, -25 Scott 4616-18, -19, -28, -29; and 4622-18, -19, -28, -29 15 - 50 50 - 250 15 - 50 50 - 250 TC-19C-73 Scott 802230 25 - 250 TC-19C-74 Scott 801548 25 - 250 Pressure range, ps 5-17 5-17 50 - 125 50 - 125 50 - 125 50 - 125 50 - 90 65 - 90 12 - 25 25 - 40 6-16 16 - 22 60 - 125 60 - 125 ASI 00022672