Document byXRdQOLzx9yMMXJy7BxYRwEy
DATE JOB
First Draft
November 26, 1 97-1
Second Draft - December 9, 197-1
Pydraul MC Technical Sales Brochi
(Andy A,. Johnson, MICC; B2SC - 4-2462'.
PYDRAUL MC
Fire Resistant, Water-Free Hydraulic Fluid ... For Mining Equipment
ovo^b
BulleVm Mo,
TOWOLDMON0022700 WATER_PCB-00007169
/
010"' .
TOWOLDMON0022701 WATER_PCB-00007170
Pydraul MC
A High-Performance Hydraulic Fluid For Safer
Hydraulic Operation With Minimum Maintenance
'
PydraulMC fire-resistant hydraulic fluid was developed spe
cifically for use in mining equipment. It is a' phosphate-ester
based formulation containing no water. It meets the fire resis
tance requirements of the U.S. Bureau of Mines Schedule #30.
Equally important, field experience since 1972 shows that Pydraul
i lu
MC^offers the following operating advantages:
.............
** Reduced Fluid Maintenance
Unlike water-based hydraulic fluids that are oil
emulsion or glycol solutions -- Pydraul MC does
not lose water by evaporation to change composition
arid viscosity.
.
* Eliminates Hazards From Spillage
Water-based fluids that evaporate off their water
component can leave behind flammable residues in
reservoirs, spill pools or crevices.
.
* Operates At Higher Temperatures_ij Pressures
Pydraul MC has excellent viscosity characteristics
and a high degree of lubricity that permits efficient
hydraulic operation at pressures up to 5,000 psi.
* Gives Equipment Protection From Corrosion
flail
.
Pydraul MCMoes not create a rust-promoting environ
. ment in operating equipment. It is chemically stable
to help eliminate corrosion problems.
2.
^Reais-Urecl TfpJernnrk of
0lO8t`<8
TOWOLDMON0022702 WATER_PCB-00007171
' . .5.
Monsanto's development of fire protection for industrial hydraulic operations began with the first Pydraul fluid in 1951. Pydraul fluids have since provided industry with millions of ma chine hours of safe operation.
Pydraul MC was designed to enable ore and toal mine operators meet the current safety legislation that requires a fire-resistant fluid in unattended equipment and either a fire-resistant fluid or suitable fire suppression devices in attended equipment. The initial cost and maintenance of fire suppression devices may show that a stable fluid such as Pydraul MC would be the most economical choice in the long run.
Pydraul MC is a dependable hydraulic fluid for safer operation of above- and below ground equipment with minimized maintenance. It may be used in the hydraulic systems of the following:
Power Shovels S Draglines
Blasthole Drills
Bulldozers 5 Rippers
Tractors
Scrapers 5 Graders
Crushers
Ore Feeders
Trucks
Jumbos
Ore Drills
Mechanical Loaders Scrapers
-
oto^q
TOWOLDMON0022703 WATER_PCB-00007172
4. The following pages give data that illustrate the typical properties and performance of Pydraul MC as measured by standard test procedures used to describe hydraulic operation and fire resistance:
0VO
TOWOLDMON0022704 WATER_PCB-00007173
Pydraul MC Typical Physical Properties *
Appearance Specific Gravity 25/25C. Density at
14 0 F. 77F.
Neutralization No. (mg KOH/g) max. Moisture (max.) $ Viscosity
Centistokes 0 40F. 6 100F. 6 210F.
Clear Green Liquid 1.098
1.075 grams/ml. .1.100 grams/ml. ' 0.30
0.15
1250 cs (59 cs
6.9 cs
SSU 6 40F. e 100F. e 210F.
5800 SSU 320 SSU 48 SSU
Pour Point
Coefficient of Thermal Expansion per F.
Specific Heat BTU/lb./F. 0 77F.
Thermal Conductivity BTU/hr./ft./'F.
Solubility in Water
.
-10F., 0.00034 0.39 0.0728 Negligible
*Data based upon typical quality control samples tested in our laboratories. Complete sales specifications axe furnished on request.
01081S1
V,
yy
TOWOLDMON0022705 WATER_PCB-00007174
___ _f eg g SS58SI
8? 8 S 8 88 888888
) )
TEMPERATURE. DEGREES FAHRENHEIT
J
I 01081"
TOWOLDMON0022706 WATER_PCB-00007175
--.--r----------------1'
{,
OVO
TOWOLDMON0022707 WATER_PCB-00007176
Pydraul^MC Typical Performance Propert 1 e ;3
7.
Foam Test (ASTM D892) Sequence 1, 2, 3
Pass
Rust Test ASTM D-665 (Sequence A)
- Pass
Hydrolytic Stability Test (MIL-H-19457)
Pass
Oxidation and Corrosion Test (FS791-3S08) (168 hr., 2S0F., 5 1 air per hr.)
O Metal Weight Changes, mg/cm
Magnesium Aluminum Cadmium Steel Copper
'
-0.01 + 0.05
-0.01 + 0.01 -0.02
Acidity Increase, NN
100F. Viscosity Increase, %
13.1
00 Lft
0-4
Compatibility With Materials
Metals
Pydraul MC is compatible with all the commonly used metals of construction.
Paints Other Fluids
Cured epoxy, phenolic, polyurethane and nylon based paints are satisfactory.
INTERIOR SURFACES ARE PREFERABLY LEFT UNPAINTED. Pydraul MC is miscible in all proportions with the Pydraul E and Pydraul C Scries of fluids. It is essentially insoluble in water.
Packings, Seals, Hoses and Bladders .
Materials compatible with Pydraul MC are . necessary for dynamic or moving seals.
For static seals they are preferred but not essential.
Recommended VI TON NYLON TEFLON FLUOREL SILICONE
Marginal*' BUTYL EPR
Unsatisfactory BUNA--N NEOPRENE NATURAL RUBBER
'`Although generally classified as marginal with Pydraul fluids, butyl and EPR (ethylene propylene rubber) have proven satisfactory in equipment operating
under certain conditions of temperature, fluid cleanliness, maintenance, etc. For best service under general all-around operating conditions, elastomers of Viton, Nylon, Fluorel, Teflon, and silicone are suggested.
' 0108154
TOWOLDMON0022708 WATER_PCB-00007177
PydraulMC FireifResistance Properties
Flash Point
Fire Point
Autognenous Ignition Temperature (ASTM D2155)
Factory Mutual High Pressure Spray Test
Crest fluid sprayed @ 1000 psi through orifice, passing through flame of propane torch.)
Factory Mutual Hot Channel Test
(Test fluid sprayed 0 1000 psi through orifice, onto hot channel iron 0 1300F.)
U.S. Bureau of Mines Approval Schedule 30
4 750F S25F. 800F Pass Extinguished in less than 5 sec. after torch removed. Pass
Yes, Number 30-6
Fire Resistance Advantages of Pydraul Pydraul fluids protect hydraulic equipment and personnel with
permanent fire protection. Pydraul fluids contain no water to evaporate and leave a flammable residue. During their many mil lions of machine hours of use, Pydraul fluids have been acciden tally sprayed over molten metal, through electrical arcs, into flames and sparks without disaster. They pass all of the important ignition tests for fire resistance.
"NOTE: Materials designated 'fire resistant' generally arc more difficult to ignite, or once ignited, bum at a slower rate than corresponding conventional
r materials. This term does not mean that fire resistant materials will not bum. However, when properly used. Monsanto's fire resistant PYDRAUL00 HYDRAULIC FLUIDS are useful in helping customers meet their fire safety requirements."
j^ Movt- lo j'TOw}
108i55
|
TOWOLDMON0022709 WATER_PCB-00007178
9.
CONVERTING MINING EQUIPMENT HYDRAULIC SYSTEMS TO PYDRAUL MC
Regardless of the type of hydraulic fluid being used, con verting a system to Pydraul MC is easy. Virtually every type of equipment that uses fire-resistant hydraulic fluid has been con verted to Pydraul phosphate-ester fluids. Most equipment manufac turers are experienced in Pydraul fluid conversions and should be consulted.
If changing seals is necessary, equipment manufacturers can recommend which to change, and many carry a supply of compatible seals. Laboratory tests and operational experience show Viton*, Teflon*, and silicone to be the preferred elastomers.
To replace other fluids which are compatible with Pydraul and where compatible seals are already in the system, it is only necessary to add Pydraul MC as make-up fluid. It is not necessary
*
to drain or clean. However, when converting from petroleum oils, non-compatible synthetic fluids, water-glycol fluids, or watcrin-oil emulsions -- the following steps are recommended. These conform to USA Standard H93.5 -- 1973.
Changing from Petroleum Oil
1. Completely drain and clean the system. Small amounts
of oil will not interfere with the performance of
Pydraul, but resistance to fire is reduced by the
amount of oil left in the system. 2. Drain and blow out pipelines. Manually clean valves
and reservoirs.
Oioei&b
^Registered trademark of E.I. Du Pont de Nemours f, Co., Inc.
^
' TOWOLDMON0022710 WATER_PCB-00007179
10.
3. Open or reraove-and-drain all valves. Replace gaskets; packings, and seals with compatible materials. It is particularly important to change dynamic seals. Static seals do not necessarily have to.be changed if they are tot leaking. Non-compatible static seals can be replaced
. when the component is disassembled for maintenance.
4. Remove pumps, accumulators, and cylinders, if neces sary, for draining. Replace packings, seals, gaskets, and bladders with materials compatible with Pydraul.
5. Check component functions before the system is closed and fluid is added.
6. If the system cannot be completely drained, if may have to be flushed out with a small amount of Pydraul.
Changing from Water-Gfycol or Water-in-Oi1 Emulsion
1. Drain and clean system thoroughly. Remove all traces
of water. Empty all lines and low points or dead
pockets in components.
"
2. Clean with steam or warm water. Follow by blowing with dry air.
3. Check sealing materials, hoses, and accumulator bags. ' Replace if necessary with compatible materials.
4. Install a minimum charge of Pydraul and operate the system from 16 to 24 hours. During this period, in spect the reservoir. If water or other contaminants float to the top, remove by skimming.
,'
01081S7
TOWOLDMON0022711 WATER_PCB-00007180
11.
S. Drain the flushing charge immediately after shut-down while the fluid is warm. Drain all isolated points or parts which do not drain back to the reservoir. If water is apparent in fluid clinging to walls, wipe down all accessible parts.
Ask the Monsanto fluids specialist for suggestions and assistance. He may be reached by phoning the nearest sales office listed on the back cover.
010^6
TOWOLDMON0022712 WATER_PCB-00007181
12.
. Pydraul MC Toxicity and Safe Handling Animal studies indicate that Pydraul MC can be classed as practically non-toxic when considered as an industrial fluid. It is non-irritating when the skin is exposed to the fluid. In case of skin contact wash off with soap and water as a hygenic procedure. In the case of eye contact flush with copious amounts of water. Due to its low order of toxicity, Pydraul MC requires no special handling precautions.
TOWOLDMON0022713 WATER_PCB-00007182
CUSTOMER SERVICE CENTERS
AKRON', OHIO 44373
260 Springsidc Drive Montrose Development Park Tel. (216) 666 4111
ATLANTA. GEORGIA 30339
320 Interstate North Parkway Suite 500 Tet (404) 432-7111
BOSTON, MASSACHUSETTS 02149 Everett Station Tel. (617) 387-5010
CHICAGO, ILLINOIS
3158 Dcs Plaines Avc. Dps Plaines. Illinois 60D1Q . Tel. (312) 29G-6688
_
CINCINNATI, OHIO 45236
8041 Hosbrook Road Tel. (513) S84-1100
DETROIT, MICHIGAN
500 Northland Towers Wcsl Southfield. Michigan 48075 Tel. (313) 357-0910
HOUSTON, TEXAS 77027
1301 Post Oak Tower 5051 Westheimcr Road Tel. (713) 621-9550
IOS ANGELES, CALIFORNIA
1401 Dove Street Newport Beach, California 92660 Tel. (7147) 833-9150
NEW YORK, NEW YORK 10036
1114 Avenue of the Americas Tel. (212) 764-5000
ST. LOUIS, MISSOURI 63166
800 N. Lindbergh Bivd. Tel. (314) 694-1000
SAN FRANCISCO BAY AREA
2710 Lafayette Santa Clara, Californio 95052 Tel. (408) 243-0414
SEA1TLE, WASHINGTON 98121
2112 Third Avenue Tet. (206) 622-4203
WILMINGTON, DELAWARE 19810
Suite 204, Bancroft Bldg. 3411 Si/vcrsidc Road Tel. (302) 478-4600
Monsanto Industrial Chemicals Co. A Unit of Monsanto Company S00 N. Lindbetgh Blvd., St. Louis. Mo. 63166
0108160
''Nothing contained herein is io be construed as a recommendation to use any product in conflict with any patent