PLAINTIFF'S EXHIBIT SHELL OIL COMPANY ENGINEERING STANDARDS DESIGN STANDARD 5-1 INSULATION AUGUST 1959 ABS-061217 SHELL OIL COMPANY ENGINEERING STANDARDS I NSULAT I ON DESIGN STANDARD 5-1 AUGUST 1959 PAGE I OF I INDEX DESIGN STANDARD 5-1.1 GENERAL 5-1.1.1 Scope 5-1.2 HOT SERVICE 5-1.2.1 5-1.2.2 5-1.2.3 5-1.2.4 5-1.2.5 Insulation Requirements Insulation Thicknesses Personnel Protection Insulation Steam Trap Insulation Steam Tracing Insulation _ 5-1.3 COLD SERVICE 5-1.3.1 Insulation Requirements 5.1.3.2 Insulation Thicknesses CHARTS APPENDED CHART NO. I - Hot Service - Recommended Insulation Thicknesses CHART NO. 2 - Cold Service - Recommended Insulation Thicknesses PAGE NO. 1 1 1 2 2 2 2 3 ABS-0 61218 SHELL 01L COMPANY ENGINEERING STANDARDS. 5-1.1 GENERAL DESIGN INSULATI ON STANDARD 5-1 AUGUST 1959 PAGE I OF 3 5.1-1.I SCOPE This etandard covers the Engineering design of insulation systems for piping, vessels, exchangers, tanks, pumps, compressors, and turbines in hot and cold services. It 1b Intended to provide a basic guide for consideration of recurring in sulation design probleme and to inform engineers of preferred design procedures. 5-1.2 HOT SERVICE 6-1.2. I INSULATION REQUIREMENTS . | Hot service piping and equipment shall be insulated to conserve energy, maintain process stability, protect personnel, or for a combination of these reasons. In general, hot service insulation shall be applied on piping op erating above 1509? and on equipment operating above 1709F.. In addition, any hot surfaces of large area such as vessels and exchangers which operate below 170P shall be considered to determine the need for insulation for process stability. .2 Valves, flanges and fittings, except unions. In steam and boiler feed water services shall be insulated,. Valves, flanges and flanged fittings in other services shall not be insulated except where required for personnel protec tion, unless specified by Shell. Welded and screwed fittings, except unicr.e in. insulated lines shall be insulated. 5-1.2.2 INSULATION THICKNESSES Insulation thicknesses for hot service piping, vessels, exchangers, pumps, compressors, and turbineB shall be in accord with appended chart No. 1. The recommended thicknesses are based upon personnel protection requirements The need for additional thickness for energy conservation or process stabil ity shall be considered. 2 Insulation thickness for hot service tanks 12 feet OD or leB8 shall be 1 inch and shall be 1^ inches for tanks over 12 feet OD. The density of the insulation for tanks over 12 feet OD shall be dependent upon economic fac tors and specified by Shell for each installation. .3 Insulation thicknesses recommended in appended Chart No. 1 are based on ar. insulating material having approximate thermal conductivity values of O.bh at 200F and O.58 at 600F. Materials with other conductivity values may be substituted provided there is a corresponding adjustment in insulation thicknesses. ABS-061219 INSULATION DESIGN STANDARD AUGUST 1959 PAGE 2 OF 3 5-1 SHELL OIL COMPANY ENGINEERING STANDARDS 5-1.2.3 PERSONNEL PROTECTION INSULATION .i Insulation thicknesses for personnel protection shall be such that the ex ternal surface termperature of the insulation shall be a maximum of 150F for piping and 170F for other equipment. The effect of weatherproof cover ings shall not be considered in establishing the insulation thicknesses. 2 Insulation for personnel protection shall generally be applied to hot Burfaces which can be inadvertently contacted by personnel in normal perfor mance of their duties. Such hot surfaces shall be insulated to a height 7 feet above normal walking or standing surfaces. .3 Unless specified by Shell internally insulated equipment such as cat cracker vessels and lines., reformer and desulphurizer reactors, etc., shall not be insulated for personnel protection by the insulation contractor even though their surface temperatures exceed 170F. Personnel protection for these hot surfaces shall be applied, when required by Shell. .4 Personnel protection on equipment from which it is desirable to dissipate heat, such as steam condensate knockout drums and exchangers with cooling water on one side, shall be expanded metal guards instead of insulation. STEAM TRAP IHSULATIOH Steam traps and their outlet piping shall not be insulated except for personnel protection or where the outlet piping is arranged bo that a liquid head of condensate can collect. Inlet piping to traps shall be insulated. 5-1.2.5 STEAM TRACING INSULATION Piping or equipment which is steam traced shall be covered with oversized insulation to include the Tracer Lines. Insulation thicknesses shall be selected from appended Chart No. 1 with the thickness for pipe insulation based on the size used. 2 Steam traced systems shall be completely insulated including equipment, valves, flanges fittings and tracer line loops. 5-1.3 COLD SERVICE 5-1.3.I INSULATION REQUIREMENTS Cold service equipment and piping Bhall be completely insulated to conserve energy, maintain process stability, protect personnel, prevent moisture con densation, or for a combination of these reasons. In general, cold service insulation Bhall be applied on equipment and piping operating at 50F, or less which are part of a refrigeration system or contain fluids which are cooled by a refrigeration system. ABS-061220 li SHELL 01L COMPANY ENGINEERING STANDARDS INSULATION DESIGN STANDARD 5-1 AUGUST 1959 PAGE 3 OF 3 5-1.3.2 INSULATION THICKNESSES . | Insulation thicknesses for cold service equipment shall be in accord with appended Chart No. 2. The recommended thicknesses, which are based upon prevention of moisture condensation, will in general be adequate for energy conservation, process stability, and personnel protection requirements. When additional thicknesses are necessary, the required insulation thick nesses shall be calculated. Insulation thicknesses recommended in appended Chart No. 2 are based on an insulating material having approximate thermal conductivity values of 0.35 at O^F and 0.39 at 70F. Materials with other conductivity values may be substituted provided there is a corresponding adjustment in insulation thicknesses. (J ABS-061221 SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION DESIGN STANDARD 5-1 AUGUST 1959 CHART NO. | HOT SERVICE - RECOMMENDED INSULATION THICKNESSES FOR COMBINATION OF ENERGY CONSERVATION, PERSONNEL PROTECTION, AND PROCESS STABILITY VESSELS, EXCHANGERS, PUMPS, COMPRESSORS, AND TURBINES FOR INSULATION SURFACE TEMPERATURES OF 170F. INSULATION THICKNESS, INCHES MAXIMUM TEMPERATURE, F 1m 600 800 2 2)4 3 950 1100 1200 PIPE SIZE INCHES 1 Down m 2 3 4 6 8 10 12 14 16 18 20 22 24 1 6S0 550 550 500 500 430 PIPING FOR INSULATION SURFACE TEMPERATURES OF 150F. INSIDE UNIT AREAS INSULATION THICKNESS, INCHES w2 2)4 3 3)4 MAXIMUM TEMPERATURE, #F. 850 1100 1200 750 900 1200 1200 750 900 1150 1200 700 850 1150 1200 1200 650 800 1000 1150 1200 600 800 900 1050 1200 600 750 900 1050 1200 600 750 900 1000 1150 600 750 850 1000 1100 550 700 800 950 1050 550 700 800 900 1050 550 700 800 900 1000 550 650 800 900 1000 550 650 800 900 1000 550 650 750 850 950 4 1200 1200 1200 1150 1150 1150 1100 1100 1100 4)4 1200 1200 1200 1200 1200 1200 OUTSIDE UNIT AREAS Thicknesses shall be selected on Individual basis for each rofinery depending upon economic Iactors, personnel protection, and process stability* NOTES 1. The obove tobies are based on 80F. ambient still olr and on on Insulating moterlol.hovlng approximate thermal conductivity volves of 0.44 at 200F. and 0.5B at 600>F. 2. Tho above tobies do not include the insulating effect of finol coverings which con bo expected to further reduce Insulation surface temperatures. ABS-061222 SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION DESIGN STANDARD S-1 AUGUST 1959 CHART HO. 2 COLD SERVICE - RECOMMENDED INSULATION THICKNESSES FOR COMBINATION OF ENERGY CONSERVATION, PROCESS STABILITY, PERSONNEL PROTECTION, AND CONDENSATION PREVENTION IRON PIPE SIZE INCHES 1 Down IK 2 3 4 6 8 10 12 14 16 IB 20 24 30 Vassal OO Inches 36 42 48 54 60 66 72 78 84 96 108 120 144 Over 144 To Flat PIPING, VESSELS, EXCHANGERS, PUMPS, AND COMPRESSORS INSULATION THICKNESS, INCHES l IK 2 2K 3 3K 4 4K 5 MINIMUM TEMPERATURE, F 50 25 -10 -25 -70 50 30 15 -15 -45 50 30 15 -15 -45 -90 50 30 15 -10 35 -60 50 30 20 0 30 -55 50 45 25 0 -25 -45 -70 _ 45 25 0 -15 -35 -60 45 30 ID 10 25 50 45 30 15 -5 -25 -45 -65 45 30 15 0 -25 -40 -55 45 30 20 0 -25 -35 55 45 30 20 0 -25 -35 -50 50 30 20 0 -25 -35 -45 -65 50 30 20 0 -25 -35 -45 -65 50 30 20 5 -10 -25 .40 -60 50 30 20 10 50 30 25 10 50 30 25 10 50 35 25 10 50 40 25 10 50 40 25 10 50 40 25 10 30 40 25 10 50 40 25 10 50 40 25 10 50 40 25 10 50 40 25 10 50 40 25 to 50 40 25 15 -5 -25 -40 -5 -20 -35 -5 -20 -35 -5 -20 -35 -5 -20 40 -5 -15 30 0 -15 40 0 -15 40 0 -15 40 0 -15 40 0 15 -30 0 -15 -30 0 -IS 40 0 -10 -25 55 55 50 -50 -50 -50 -50 -45 -45 -45 -45 -45 -45 -40 5H 6 -65 -65 -65 -60 -75 -60 -75 -60 75 -55 -65 NOTES 1. The above tables are based on 9tPF. ambient still air, 80% relative humidity, end on on Insulating material having approximate thermal conductivity values ol 0.35 at 0"F. and 0.39 at 70F. 2. The above tables are based on the prevention ol moisture condensation. 3. The above tables do not include the insulating effect of final covering. ABS-061223 SHELL OIL COMPANY ENGINEERING STANDARDS o MATERIAL AND EQUIPMENT STANDARD 5-2 INSULATION AUGUST 1959 ( ). ABS-061224 SHELL OIL COMPANY ENGINEER ING STANDARDS INDEX MATERIAL AND EOUIPMENT STANDARD 5-2.1 GENERAL 5-2.1.1 Scope 5-2.1.2 Material Requirements 1NSULATIOH M 4 E STANDARD 5-2 AUGUST 1959 PAGE 1 OF 2 PAGE NO. 1 1 1 W W W W ro V I V I V I V I -P* -P" -P" -P" -p- -P* P U l 5-2.2 HOT SERVICE 5-2.2.1 Piping .1 Insulation and Coating Materials .2 Final Coverings .3 Bandings .4 Accessories 5-2.2.2. Vessels .1 Insulation and Coating Materials .2 Final Coverings 3 Bandings .4 Accessories 5-2.2.3 Exchangers .1 Insulation and Coating Materials .2 Final Coverings .3 Bandings .4 Accessories 5-2.2.4 Tanks. .1 Insulation and Coating Materials .2 Final Coverings 3 Accessories 5-2.2.5 Pumps, Compressors and Turbines .1 Insulation and Coating Materials .2 Final Coverings .3 Accessories 5-2.3 COLD SERVICE 5-2.3-1 Piping .1 Insulation and Coating Materials .2 ^rrlDe' .3 .4 Accessories 1 1 1 2 2 ;2 2 2 3 3 3 3 4 4 4 4 4 4 4 5 5 5 5 -- ABS-061225 5 5 >\ 6 CTNONVn^ VI SHELL OIL COMPANY ENGINEERING STANDARDS t HSU LA_T l_Q N MAE STANDARD 5-2 AUGUST 1959 PAGE 2 OF 2 INDEX (CONTINUED) MATERIAL AND EQUIPMENT STANDARD 5-2.3.2 Vessels .1 Insulation and Coating Materials .2 Final Coverings 3 Bandings .4 Accessories 5-2.3-2 Exchangers .1 Insulation and Coating Materials .2 Final Coverings 3 BandingB .4 Accessories 5-2.3-4 Pumps and Compressors .1 Insulation and Coating Materials .2 Final Coverings 3 Accessories CHARTS APPENDED CHART NO. 1 - Hot Service Insulation and Coating Materials CHART NO." 2 - Cold Service Insulation and Coating Materials PAGE NO. 6 6 7 7 7 7 7 7 8 8. 8 8 8 8 ABS-061226 SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION M & E STANDARD 5-2 AUGUST 1959 PAGE I OF 8 5-2.1 GENERAL 5-2-1.I SCOPE This standard covers the selection of materials for the insulation of piping, vessels, exchangers, tanks, pumps, compressors, and turbines in hot and cold services. It is intended to establish a standard of quality applicable to'all in sulating materials. 5-2.I.2 MATERIAL REQUIREMENTS I Reference to a particular material or equal shall serve only as a precise identification of the type and quality of the material required. Alternate materials vill be considered. Sufficient engineering data for.evaluation of alternate materials shall accompany proposals. Shell shall be the sole judge of the equality, design, workmanship, and suitability of materials offered on an alternate basis. 2 All aluminum sheets and elbows used for final covering in hot services shall have an asphalt, polyethylene, or equal, protective barrier factoryapplied to the under side when used with insulations which are chemically reactive with aluminum. 5-2.2 HOT SERVICE 5-2.2.I PIPING .1 INSULATION AND COATING MATERIALS Insulations and' coatings shall be in accord with.appended Chart Ho. 1. ; .2 FINAL COVERINGS ' . .1 Final covering for piping insulation inside offlee'buildings shall be 8ounce canvas saturated with Arobol Mfg. . Co. Arobol, or equal. .2 Final covering for straight piping' insulation inside, unit areas shall be flat aluminum sheets, 0.016 inch, utility grade, half hard-, mill finished, in cut and machine rolled sections approximately 3 feet long. Final covering for welded elbow insulation inside unit areas shall be preformed aluminum elbows, Childers Mfg. Co., General Aluminum Supply Co., or equal. .3 Final covering for straight, piping insulation outside unit areas shall be asbestos-asphalt felt in cut and rolled sections approximately 3 feet long, Johns -Manvilie Corp., Double-Coated Flexstone, or equal. Final covering for welded elbow insulation outside unit areas shall be weather proofing compound, Philip Carey Mfg. Co. Thermotex B> or equal. ABS-061227 INSULATION M & E STANDARD 5-2 AUGUST 1959 PAGE 2 OF 8 SHELL OIL COMPANY ENGINEERING STANDARDS .3 BANDINGS I Banding shall not be applied on one-piece pipe insulation. .2 Banding on insulation under aluminum final covering shall he: I Piping 10 inches and smaller - 0.051 inch diameter, soft, type 18-8, stainless steel wire; *2 Piping 12 inches through 16 inches - 0.064 inch diameter, soft, type 18-8, stainless steel wire; 3 Piping 18 inches and larger - l/2 inch x 0.015 inch, soft, type 18-8, stainless steel bands and seals. 3 Banding on insulation under asbestos-asphalt felt final covering and on asbestos-asphalt felt final covering shall be: I Piping 10 inches and smaller - 0.064 inch diameter, galvanized, soft, iron wire; 2 Piping 12 inches through 16 inches - O.683 inch diameter, galvanized, soft, iron wire; 3 Piping l8 Inches and larger - l/2 inch x 0.020 inch, soft, aluminum bands and aluminum seals. 4 Banding on aluminum final covering shall be 1/2 inch x 0.020 inch, soft aluminum bands and aluminum seals. .4 ACCESSORIES .1 Glass fabric shall be Tvinsburg - Miller Co. Glasfab, 20 x 20 mesh, asphalt treated, or equal. 2 Lacing wire shall be 0.051 inch diameter, soft, type 18-8, stainless steel wire. 5-2.2.2 VESSELS .1 INSULATION AND COATING MATERIALS Insulations and coatings shall be in accord with appended Chart No. 1. .2 FINAL COVERINGS .I Final covering for vertical vessel shell insulation shall be corrugated aluminum roofing sheets, 1-1/4 inches x l/4 inch corrugations, 0.019 inch, standard grade, half hard, mill finished. ABS-061228 SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION M 4 E STANDARD 5-2 AUGUST 1959 PAGE 3 OF 8 .2 Final covering for horizontal vessel shell insulation shall be flat alu minum sheets,- 0.020 inch, utility grade, half hard, mill finished. . 3 Final covering for vessel head insulation shall be weatherproofing com pound, Philip Carey Mfg. Co. Thermotex B, or equal. .3 BANDINGS t| Banding on vessel shell insulation shall be: 1 Vessels 8 feet O.D. and smaller - l/2 inch x 0.015 inch, soft, type l8-8, stainless steel bands. .2 Vessels larger than 8 feet O.D, - 3/* inch x 0.020 inch, soft, type 18-8, stainless steel bands with A. J. Gerrard and Co. Expand-R-Strap, Techalloy Co. Breather Spring, or equal, expansion sections and stain less steel seals. 2 Banding on vessel head insulation shall be 1/2 inch x 0.015 inch, soft, type 18-8, stainless steel hands anchored with lacing wire hair pins to 1/2 inch nut blanks welded to heads. 3 Banding on vessel shell final covering shall be: 1 VesselB 8 feet O.D. and smaller - 3/^ inch x 0.025 inch, soft, alu minum bands with aluminum seals. .2 Vessels larger than 8 feet O.D., - 3/^ incl1 x 0.020 inch, soft, type 18-8, stainless steel bands with A. J. Gerrard and Co. Expand-R-Strap, Techalloy Co. Breather Spring,- or equal, expansion sections and stain less steel seals. . : ' -. '.N ACCESSORIES-'' ;' 1 Wire mesh shall be 1 inch hex mesh of 0.032 .inch diameter, 3 twis.t, soft, type 18-8, stainless steel wire. 2 Lacing wire shall be 0.051 Inch diameter, soft,' type 18-8, stainless steel wire. 5-2.2.3 EXCHANGERS . 1 INSULATION AND COATING MATERIALS Insulations and coatings shall be in accord with appended Chart No. 1. ABS-061229 INSULATI ON MAE STANDARD 5-2 AUGUST 1959 PAGE H OF 8 .j SHELL OIL COMPANY ENGINEERING STANDARDS .2 FINAL COVERINGS I Final covering for exchanger shell and channel insulation shall he flat aluminum sheets, 0.020 inch, utility grade, half hard, mill finished, in cut and machine rolled sections approximately 3 feet long. .2 Final covering for exchanger shell head and channel head insulation shall he weatherproofing compound, Philip Carey Mfg. Co. Thermotex B, or equal. .3 BANDINGS I Banding on exchanger shell and channel Insulation shall he 1/2 inch x 0.015 inch, soft, type 18-8, Btainless steel hands with stainless steel seals. .2 Banding on exchanger shell and channel final covering shall he 3/4 inch x 0.025 inch, soft, aluminum hands with aluminum seals. / ACCESSORIES .1 Wire mesh shall be 1 inch hex mesh of 0.032 inch diameter, 3 twist, soft, type 18-8, stainless steel wire. .2 Lacing wire shall be 0.051 inch diameter, soft, type 18-8, stainless steel wire. 5-2.2.1 TANKS .) INSULATION AND COATINGS MATERIALS Insulations and coatings shall he in accord with the appended Chart No. 1. .2 FINAL COVERINGS AND BANDING .1 Tanks 12 feet O.D. and smaller,- Final covering and handing for tank in sulation shall he in accord with section 5-2.2.2 for hot service vessels. 2 Tanks larger than 12 feet O.D. - Final, covering for tank insulation shall he flat asbestos-cement sheets, 4 feet x 8 feet x 3/l6 inch thick, JohnsManville Corp. Asbestocite, or equal. .3 ACCESSORIES I Tanks 12 feet O.D. and smaller - Accessories shall he in accord with section 5-2.2.2. for hot service vessels. ABS-081230 SHELL OIL COH PAH y ENGINEERING STANDARDS I HSULAT I OH M & E STANDARD 5-2 AUGUST 1959 PAGE 5 OF 8 .2 Tanks larger than 12 feet O.D. - Accessories shall he in accord with appended drawing. No. B-1235. 5-2.2-5 PUMPS, COMPRESSORS AND TURBINES .1 INSULATION AND COATING MATERIALS Insulations and coatings shall be in accord with appended Chart No. 1, .2 FIHAL COVERINGS Final covering for insulation shall be weatherproofing compound, Philip Carey Mfg. Co. Thermotex B, or equal. .3 ACCESSORIES .1 Wire mesh shall be 1 inch hex mesh of 0.032 inch diameter, 3 twist, soft, - type 18-8, stainless steel wire. .2 Lacing wire shall be 0.051 inch diameter, soft, type 18-8, stainless steel wire. 5-2.3 COLD SERVICE 5-2.3.I PIPING .1 INSULATION AND COATING MATERIALS . Insulation and coatings shall be in accord with appended Chart No. 2. .2 ; FINAL COVERINGS .1 Final coverings for piping insulation inside office buildings shall be 8-ounce canvas saturated with Arobol Mfg. Co. Arobol, or equal. .2 Final covering for straight piping insulation inside unit areas shall be flat aluminum Bheets, 0.0l6 inch, utility grade, half hard, mill finished, in cut and machine rolled sections approximately 3 feet long. .3 Final covering for straight piping insulation outside Unit areas shall be asbestos-asphalt felt in cut and rolled sections approximately 3 feet -long, Johns-Manville Corp. Double Coated Flexstone, or equal. 4 Final covering for welded elbow insulation inside unit areas shall be pre formed aluminum elbows, Childers Mfg. Co., General Aluminum Supply Co., or equal. ABS-061231 INSULATIOH MAE STANDARD 5-2 AUGUST 1959 PAGE 6 OF 8 SHELL OIL COMPANY ENGINEERING STANDARDS 5 Final covering for welded elbows outside unit areas shall be weather proofing compound, Pittsburgh Corning Corp. Pittcote 300, or equal. . .3 BANDINGS . I Banding on insulation under aluminum final covering shall be: .1 Piping 10 inches and smaller - 0.051 inch diameter, soft, type 18-8, stainless steel wire; .2 Piping 12 inches through l6 inches - 0.064 inch diameter, 3oft, type 18-8, stainless steel wire. .3 Piping 18 inches and larger - 1/2 inch x 0.015 inch, soft, type l8-8, stainless steel bands with stainless steel seals. .2 Banding on insulation under asbestos-asphalt felt final covering and on asbestos-asphalt felt final covering shall be: I Piping 10 inches and smaller - 0.064 inch diameter, galvanized, soft, iron wire; .2 Piping 12 inches through 16 inches - 0.083 inch diameter, galvanized, soft, iron wire. 3 Piping 18 inches and larger - l/2 inch x 0.020 inch, soft, aluminum bands and aluminum seals. 3 Banding on aluminum final covering shall be l/2 inch x 0.020 inch, soft, aluminum bands and aluminum seals. ACCESSORIES . I Glass fabric shall be Twinsburg-Miller Co. Glasfab, 20 x 20 mesh, asphalt treated, or equal. 2 Lacing wire shall be 0.051 inch diameter, soft, type l8-8, stainless steel wire. 6-2.3.2 VESSELS .1 INSULATION AND COATING MATERIALS Insulations and coatings shall be in accord with appended Chart No. 2. ABS-081232 SHELL OIL COMPANY ENGINEERING STANDARDS I NSULATI OH M & E STANDARD 5-2 AUGUST 1959 PAGE 7 OF 8 2. FINAL COVERINGS .I Pinal covering for vertical vessel shell insulation shall he corrugated aluminum roofing sheets, 1-1/4 inches x l/4 inch corrugations, 0.019 inch, standard grade, half hard, mill finished. 2 Final covering for horizontal vessel Bhell insulation shall he flat al uminum sheets, 0.020 inch, utility grade, half hard, mill finished. 3 Final covering for vessel head insulation shall he weatherproofing com pound, Pittsburgh Corning Corp. Pittcote 300, or equal. .3 BANDINGS .1 Banding on vessel shell insulation shall he: .1 Vessels 8 feet O.D. and smaller - l/2 x 0.015 inch, soft, type 18-8, stainless steel bands with stainless steel seals; .2 Vessels larger than 8 feet O.D. - "i/h inch x 0.020 inch, soft, type 18-8, stainless steel bands with stainless steel seals. .2 Banding on vessel head insulation shall he l/2 inch x 0.015 inch soft, type 18-8, stainless steel hands anchored with lacing wire hair pins to 1/2 nut blanks welded to heads. .3 Banding on vessel shell final covering shall he 3/4 inch x 0.025 inch, Boft, aluminum bands with aluminum seals. .4 ACCESSORIES .1 Glass fabric shall be Tvinsburg-Miller Co. Glasfab, -20 x 20 mesh, asphalt treated, or equal. . .2 Lacing wire shall be 0.051 inch diameter, soft, type 18-8, stainless ; steel wire. 5-2.3.3 EXCHANGERS .1 IHSUUATfON AND COATING MATERIALS Insulations and coatings shall be in accord with appended Chart No. 2. .2 FINAL COVERINGS . I Final covering for exchanger shell and channel insulation shall be flat aluminum sheets, 0.020 inch, utility grade, half hard, mill finished, in cut and machine rolled sections approximately 3 feet long. ABS-061233 IHSULATIOH M & E STANDARD 5-2 AUGUST 1959 PAGE 8 OF 8 SHELL 01L COHPANY ENGINEERING STANDARDS 2 Final covering for exchanger shell head and channel head insulation.' shall be weatherproofing compound, Pittsburgh Corning Corp. Pittcote 300, or equal. .3 BANDINGS .| Banding on exchanger shell and channel insulation shall be 1/2 inch x 0.015 inch, soft, type l8-8, stainless steel bands with stainless steel seals. .2 Banding on exchanger shell and channel final covering shall be 3/^ inch x 0.025 inch,.soft, aluminum bands with aluminum seals. .4 ACCESSORIES . I' Glass fabric shall be Twinsburg-Miller Co. Glasfab 20 x 20 mesh, asphalt treated, or equal. ' 5-2.3.4 PUMPS AND COMPRESSORS .1 INSULATION AND COATING MATERIALS Insulation and coatings shall be in accord with appended Chart No. 2. .2 FINAL COVERINGS Final covering for insulation shall he weatherproofing compound, Pittsburgh Coming Corp. Pittcote 300, or equal.. 3 ACCESSORIES Glass fabric shall be Twinsburg-Miller Co. Glasfab, 20 x 20 mesh, asphalt treated, or equal. ABS-061234 SHELL OIL COMPANY ENGINEERING STANDARDS HOT SERVICE INSULATION AND COATING MATERIALS INSULATION M S E STANDARD 5-2 SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION M & E STANDARD 5-2 AUGUST |959 CHART NO. 2 *i SHELL OIL COMPANY ENGINEERING STANDARDS INSTALLATION STANDARD 5-3 INSULATION AUGUST 1959 ABS-061237 SHELL OIL COMPANY ENGINEERING STANDARDS 5-3.1 GENERAL INDEX INSTALLATION STANDARD ! 5-3.1.1 5-3.1.2 5-3,1,3 5-3.1.4 Scope Contractors Proposals Guarantees and Inspections Requirements 5-3.2 HOT SERVICE 5-3.2.1 General 5-3.2.2 Piping .1 Insulation .2 Final Coverings 5-3.2.3 Vessels .1 Insulation .2 Final Coverings 5-3.2.4 Exchangers .1 Insulation .2 Final Coverings 5-3;2.5 Tanks ,1 Insulation .2 FipE^L-Coverings. : . 5-3.2.6 Pumps, Compressors and Turbines .1 Insulation .2 Final Coverings 5-3.3 COLD SERVICE 5-3-3.1 General 5-3.3-2 Pipihg . 1 Insulation .2 Final Coverings INSTALLATION INSULATION STANDARD S-3 AUGUST 1959 PAGE I OF 2 PAGE 1 1 1 1 2 2 .3 '3 3 ^ ^ 5 6 6 6 7 7 ' 8 8 8 8 8 9 9 10 ABS-061238 SHELL OIL COMPANY ENGINEERING STANDARDS INSTALLATION INSULATION STANDARD 6-3 AUGUST 1959 PAGE 2 OF 2 INDEX (CONTINUED) INSTALLATION STANDARD 5-3-3*3 Vessels .1 Insulation .2 Final Coverings 5-3.3.^ Exchangers .1 Insulation .2 Final Coverings 5-3-3.5 Pumps and Compressors .1 Insulation .2 Final Coverings DRAWINGS APPENDED DRAWING No. B-1235 - Hot Service - Details of Tank Insulation PAGE 11 11 11 12 12 13 / 13 13 13 ABS-081239 SHELL OIL COMPANY ENGINEERING STANDARDS 5-3. j GENERAL IN SULAT I OH INSTALLATION STANDARD 5-3 AUGUST 1959 PAGE I OF 13 5-3.1.I SCOPE This standard covers the installation of materials for the insulation of piping, vessels, exchangers, tanks, pumps, compressors, and turbines in hot and cold service. It is intended to establish a standard of quality for the installa tion of all insulating materials. r 5-3.1.2 CONTRACTORS PROPOSALS .I Proposals covering materials and installation Bhall be based on Shell draw ings, data accompanying requests for quotations, thicknesses in accord with Engineering Standard 5-1* materials in accordance with Engineering Standard 5-2, and installation in accord with Engineering Standard 5-3. .2 Proposals Bhall include detailed information, for approval by Shell, of proposed insulation applications which are not covered by this Standard. 5-3.1.3 GUARANTEES AND INSPECTIONS I All work shall be Bubject to inspection and approval by Shell. . 2 Contractor shall guarantee that deeign, materials and installation are in accord with Insulation Standards 5-1* 5-2 and 5-3* . 3 Contractor shall guarantee that unsatisfactory materials or work which may be rejected by Shell shall be removed and replaced without charge to Shell. .4 Contractor Bhall. guarantee that insulation which.becomes defective as a result of faulty material or workmanship within'one year from acceptance by Shell shall he replaced,without charge to Shell.- . / \. 5-3. I.N REQUIREMENTS . | Contractor shall execute joh in accord with the best practices for insula tion work with a mini mum of waste and debris and work shall present a neat and workmanlike appearance. .2 Contractor shall observe Shell safety regulation for personnel and equip ment . .3 Contractor shall plan, schedule, end coordinate his work as required. N Contractor shall he responsible for the unloading, handling, protection . and storage of materials, including construction of the required ware houses. ABS-061240 INSULATION INSTALLATION STANDARD 5-3 AUGUST 1959 [PAGE 2 OF 13 SHELL OIL COMPANY engineering standards 5 Contractor Bhall protect materials from damage and weather during all Btages of handling and application until the final covering is applied. 6 Contractor shall provide, install and remove required scaffolding. '7 Contractor shall clean surfaces to be insulated of oil, grease, loose scale, dirt, insulation debris, etc. Cold service surfaces shall be dry before applying materials. Hot service surfaces which shall operate below 220F or which shall not be in continuous operation and cold service surfaces shall be deemed and prime coated with red lead, by otherB, before applica tion of insulation in accord with protective coating Standard 19-' Wounds in the coatings shall be repaired by otherB before application of insulation. 8 Contractor shall protect against and clean up splatter of insulating mate rials. . Contractor shall maintain.a reasonably clean pite; shall remove dpbris peri odically; and upon completion of Job shall remove materials, equipment, and debriB to satisfaction of Shell. 10 Manufacturers' equipment and code name plates.shall not be covered on hot service equipment. Insulation shall be cut on h5 angle from the nameplate edges and Bealed off with a x inch wet coat of finishing, cement followed with a x inch wet coat of weather-proofing compound. Name plates oh cold service.equipment shall be installed outside of insulation. I Contractor shall apply materials in a manner to reduce shrinkage to a mini mum. Excessive cracks that develop in any materials shall be repaired with .' ; a like .material, 12 .Contractor^ shall not. apply materials to surfaces which, are to be pressure \ tested without prior'approval of. Shell, , 13 Insulation supports, anchor huts, etc. , shall be welded to equipment and piping by the fabricators, prior to any required stress relieving operation. . 5-3.2 HOT SERVICE ,' 6-3.2.I GENERAL All insulation shall be applied with the joints tightly butted. Circumfer ential joints Bhall he staggered one half a section or block length. Bagged and open joints shall be neatly filled with finishing cement. _ 2 Insulation supports on vertical vessels, exchangers and piping shall be located at the bottom of the insulated area and on 12 feet 1 inch centers thereafter on piping and vessel^. Supports shall be x inch thick and ^ the insulation thickness in width, minimum width shall be \ inch. Insulation supports on piping and exchangers shall be located a sufficient distance from the flangeB to permit removing bolts without interference or damaging ABS-061241 SHELL OIL COMPANY ENGINEERIHG STANDARDS INSULATION INSTALLATION STANDARD 5-3 AUGUST 1959 PAGE 3 OF 13 the Insalation. The 1 Inch voids between the top of supported insulation and the succeeding supports Bhall be filled with half compressed mineral wool insulation. 3. Insulation and final coverings around structural support attachments on vessels, exchangers and piping in hot service shall be closely fitted around such projections. Insulation voids in these areas shall be filled with monolithic insulation. The openings In the final coverings shall be sealed off with a fillet of sealing compound. 5-3.2.2 PIPING .I INSULATION I Straight piping 24 inches O.D. and smaller shall be Insulated with one I layer of one piece or sectional pipe insulation. Straight piping | larger than 24 Inches O.D. shall be insulated with one" layer of block insulation. The blocks shall be. either curved, flat or flat blocks cut j into beveled lags to fit the piping contours. j .2 When insulation 1b required, valves, flanges and fittings in piping lj inches and smaller, shall he Insulated with multi-layers of monolithic insulation. Valves, flanges, and fittings.In piping 2 inches and larger, when insulation Is required, shall be insulated with one layer of pre formed or cut and fitted sectional pipe insulation. Insulation shall be stopped short of uninsulated flanges and unions a sufficient distance to permit removing the holts or breaking the union. ' without damaging the insulation. The insulation Bhall be .finished off at these points on a 45 bevel and back 2 Inches under the;adjacent final covering with a inch wet coat of finishing cement followed with a y-inch'wet coat :of weatherproofing'compound. ' * ; ' "Block* oir 'sectional ineuiatibn on':straight piping shall be-'"eecurecl with bands on-afoaximum of 9-inch rentera. Banding shall not be: required on one-piece insulation. Where required, -insulation on valves, flanges and fittings shall be secured with bands as required for adequate Becure- ment. .2 FINAL COVERINGS .I Piping insulation, except welded elbowB inside unit areas, shall be covered with'flat aluminum sheets. Piping'insulation except welded el bows, outside unit areas shall be covered with asbestos-asphalt felt sheets. Piping Insulation inside office buildings shall be covered with canvaB saturated with Arobol. . 2 Welded elbow insulation inside unit areas shall be covered with pre formed aluminum elbows. Welded elbow insulation outBide unit areas shall be covered with weatherproofing compound. ABS-061242 INSULATION INSTALLATION STANDARD 5-3 AUGUST 1959 ( JGE >1 OF 13 SHELL OIL COMPANY ENGINEERING STANDARDS 3 Aluminum and asbestos-aBphalt felt final covering shall be fitted snugly over the insulation. Circumferential and longitudinal joints Bhall be lapped a minimum of 2 incheB and arranged for good water drainage. Longitudinal JointB on vertical piping shall be Btaggered. ^ Aluminum final covering shall be machine-rolled to the O.D. of the in sulation and secured with bandB on a maximum of 18-inch centers. One band shall be located on each circumferential lap. Each section of final covering on vertical piping larger than 10 inches shall be supported from the next lower section with two S clips made from the banding material. The bottom section of the final coverings shall be supported by extended insulation support clips. *5 Asbestos-asphalt felt final covering shall be secured with bands on a maximum of 9-inch centers. One band shall be installed on each circum ferential lap. 6 Weatherproofing compound final covering shall be a two-coat installation. The first coat shall be a ^ inch wet coat of finishing cement applied on top of insulation and allowed to dry thoroughly. The second coat shall he a - inch wet i coat of weatherproofing compound reinforced with glass fabric and troweled to a smooth finish. The glass fabric shall be secured as necessary With lacing wire. The glass fabric shall be omitted on , piping 4 inchesJand smaller. The weatherproofing compound final cover ing and glass fabric shall lap 2 inches under the asbestos-asphalt felt final covering on the adjacent straight piping. 5-3.2.3 VESSELS . I INSULATION I The shells.of vessels 24 inches O.D.. and smaller shall be insulated with one layer of one piece or Bectional pipe Insulation. The shells of vessels larger, than 24 inches O.D. shall be insulated with one .layer of block insulation. The blocks shall be either curved, flat/ or flat blocks cut into beveled lags to fit the shell contours. The insulation shall be secured vith bands on l8-inch centers. Bands shall be machine stretched and sealed to remove slack only. . 2 The heads of vessels shall be insulated with one layer of block insula tion. The blocks shall be either curved, flat, or flat blocks cut into segmental beveled lags to fit the head contours. This insulation and that on vessel transition sections shall be secured with bands anchored with lacing wire hairpins to ^ inch nut blanks welded to the vessel. Anchor on top heads shall be as required for good eecurement. Anchors on bottom heads, transition sections of vertical vessels, and heads of horizontal veBselB shall be on 12-inch centers. 3 As an alternate to the above, the heads of vessels 3 feet O.D. and under may be insulated with broken block insulation imbedded in a coat of mono lithic insulation. The voids between the broken blocks.shall be filled level with finishing cement. ABS-0KL243 SHELL OIL COMPANY ENGINEERING STANDARDS- I H SULATI ON I NSTALLATIQH'STANDARD 5-3 AUGUST 1959 PAGE 5 OF 13 4 FlangeB, nozzles and manways shall not be insulated unless specified by Shell. When insulation is required,- the insulation shall be'that speci fied for shells and shall be contained in a two-piece,: prefabricated aluminum removable housing. The. design, of the housing shall be submitted to Shell for approval. 5 Insulation shall be stopped short, of uninsulated flanges a sufficient distance to permit removingthe bolts-without damaging the insulation. Insulation shall be stopped short-of uninsulated nozzles and manways a sufficient distance to expose the nozzle to shell velds for inspection. Insulation shall be finished off at these pointB on a 45 bevel and back 2 inches under the adjacent final covering with a inch -vet coat of finishing cement followed with a -jj- inch wet coat of weatherproofing com pound. , . i 6 The bottom insulation support on vertical veaBels shall, be a 2 inch x 2 inch -x inch angle with one leg out,, and the other, turned down to pro vide a flashing overi the .skirt fireproofing. On hot service vessels this support shall be located i2 inches below the skirt attachment' weld seam. 7 Skirts shall be fireproofed by others. -_ , . . 2 FINAL COVERINGS " . I Vertical vessel shell insulation shall he covered with corrugated alum inum sheets. Horizontal vessel shell insulation and vertical vessel conical head and transition section insulation shall he .covqred with flat aluminum sheets.'-.--;.. - .' . ., >-.... _ ' . 2 Vessel head insulation other than ;on conical heads-, shall, .ha covered .with weatherproofing:compound. ='*-:W 3 Aluminum final^cgyer^g,shall:be,,gifted..ynugly oy^r^the'InBU^ition. Cprrugated^aluminum.. :ihaii<be. installed - withi-thegreater: dimension ,in a vertical/positioh. . Circumferential>an,^ l6n^tudinal?`joints shall . be lapped a minimum of 3 inches and arranged. for gobd ..water. drainage. Longitudinal- j'oints ..on, .vertical vessels shall.be -staggered. - Longitudi- - ml. expansion Joints in the insulation-shall be covered continuously -with-the final covering. - . .. . : ^ - .- 4 Aluminum final covering,shall be secured with hands on l8-Inph centers. One band shall be located on each cirpumfeentia1 lap on horizontal vessels. The bands shall be machine stretched and sealed to remove slack only. Each section of final covering on vertical veBBels shall he supported from the next lover section with two S clips made from inch stainless steel handing material. The bottom section offinal coverings shall he supported by clips attached to the insulation support. 5 Weatherproofing compound final covering Bhall he a two-coat application. The first coat shall be a inch wet coat of finishing-cement applied on top of the insulation and allowed to dry thoroughly. The second coat ABS-081244 -I HSULAtI ON INSTALLATION STANDARD 5-3 AUGUST 1959 "^A6E 6 OF 13 SHELL OIL COMPANY ENGINEERING STANDARDS shall he a 3/8 inch wet coat of weatherproofing compound reinforced with wire mesh and troweled to a smooth finish. The wire mesh shall he Becured together at the edgeB with lacing wire. On top heads the weatherproofing compound filial covering and wire mesh shall lap 4 inches over the aluminum final covering on the adjacent shell. On bottom heads which are not con fined within skirts and on heads on horizontal vessels, the weatherproof ing compound final covering and wire mesh Bhall lap 4 inches under the aluminum final covering on the adjacent Bhell. The wire mesh Bhall he secured with two handB on the 4-inch lapped section on all heads. 5-3.2.4 EXCHANGERS . .1 INSULATION . | The shells and channels of exchangers 24 inches O.D. and smaller shall be covered with one layer of one piece or sectional pipe insulation. The . shellB and channels of exchangers larger than 24 inches O.D. shall be covered with one layer of block insulation. The blocks shall be either curved, flat, or flat blocks cut into beveled lags to fit the shell or channel contours. .2 The shell heads of exchangers shall be covered with broken block insulation imbedded in a coat of monolithic insulation. The voids between broken blocks shall be filled level with finishing cement to the required thickness. .3 Exchangers, flanges and channel heads shall not be insulated unless speci fied by Shell. When insulation is required, it shall be the same.as that specified for shells and shall be contained in a two-piece, prefabricated, removable aluminum housing to he secured in place with bands. The design of the housing shall be submitted to Shell for approval. .i Insulation shall be stopped short of uninsulated flanges a sufficient distance to permit removing the holts without damaging the insulation. Insulation shall be stopped short of uninsulated nozzles a sufficient - distance to expose the nozzle to. shell Velds for inspection. Insulation shall be finished off at these points on a 45 bevel and back 2 inches under the-adjacent final covering with a l/4 inch wet coat of finishing cement followed with a 1/4 inch vet coat of weatherproofing compound. . s Insulation on -the shells of exchangers shall be secured with bands on l8-inch centers. Bands shall be machine stretched and sealed to remove slack only. Insulation on channels Bhall be secured with two. bands. .2 FINAL COVERINGS I Exchanger shell and channel insulation shall be covered with flat alumi num sheets. ABS-081245 SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION INSTALLATION STANDARD 5-3 ' AUGUST 1959 PAGE 7 OF 13 .2 Exchanger shell head Insulation shall he covered with' weatherproofing compound. .3 Aluminum final covering shall he fitted snugly over the insulation. Cir cumferential and longitudinal joints shall he lapped a minimum of 3 inches and arranged for good water drainage. Longitudinal joints on vertical exchangers shall he staggered. Y Aluminum final covering shall he machine rolled to the 0.:D. of- the insu lation and secured with hands on a maximum of 18-inch centers. One hand shall he located on each circumferential lap. The bands shall he. machine Btretched and sealed to remove slack only. Each section of final cover ing on vertical exchangers shall he supported from the next lover section with two S clips made from the banding material. The bottom section of final coverings on vertical exchangers shall he supported by extended insxilation support clips. 5 Weatherproofing compound final covering shall he a two-coat application. The first coat shall he a l/4 inch wet coat of finishing cement'applied on top of the insulation and allowed to dry thoroughly. The second coat * -. shall be a 3/8 inch wet coat of weatherproofing compound reinforced with wire me3h and troweled to a smooth finish. The wire mesh shall be secured together at the edges with lacing wire.. The weatherproofing compound final covering and wire mesh on integral shell heads shall" lap 4 inches under the aluminum final covering on the adjacent shell. The wire mesh shall be secured with one band on the 4 inch lapped section oh all. shell heads. The wire mesh on flanged shell, heads shall he' laced tol/2 inch nut blanks welded to the head. 5-3.2.5 TANKS . I INSULATIONS - - -v-': '.`V v . V I Tanks 18 feet O.D. and smaller shall be insulated in accord with, section . >"3*2.2 forhot -service vessels;: . ' `..V 2 Shells of tanks larger than 12 feet O.D. shall he insulated with-one layer of blanket insulation. The insulation-shall be. installed ih long vertical blankets which shall.reach from top to bottom of'the' shell. Joints shall be snugly hutted. . The blankets shall be:secured by-care fully pressing them onto..the final covering securement studs detailed on appended drawing B/1235. Circumferential bands shall not he used. Pre cautions shall he observedto install the blankets in full thick condi tion. 3 Nozzles, manways, and roofs shall not be insulated unless specified by Shell. ABS-061246 INSULATION INSTALLATI ON STANDARD 5-3 AUGUST 1959 ^|AGE 8 OF I 3 SHELL OIL COMPANY ENGINEERING STANDARDS .2 FINAL COVERINGS . I Insulation on tanks 12 feet O.D. and smaller shall be covered in accord with section 5-3.2.2 for hot service vessels. .2 Insulation on tanks larger than 12 feet O.D. shall be covered with flat asbestos-cement sheets in accord with appended drawing B/1235. The top insulation flashing angle shall be provided by others. The final cover ing securement studs shall be provided and installed by the insulation contractor. 3 Cut outs for nozzles, manways, support attachments, etc., shall be care fully fitted, flashed and sealed with sealing compound to prevent water penetration. 5-3.2.6 PUMPS, COMPRESSORS AND TURBIHES . I INSULATION >1 The cases of pumps, compressors, and turbines shall be covered with broken block insulation imbedded in a coat of monolithic insulation. The voids between broken blocks shall be filled level with finishing cement to the required thickness. .2 Flanges, bearing housings, threaded connections, and supports shall not be insulated unless specified by Shell. .3 The insulation shall be stopped short of uninsulated flanges a sufficient distance to permit removing the bolts without damaging the insulation. Insulation shall he finished off at these flanges on a 45 bevel/ ; : .2 FINAL COVERINGS Pump, compressor and turbine Insulation shall he covered with a two-coat final covering. The first coat shall be a 1/4 inch vet coat of finishing cement applied on top of the insulation and allowed to dry thoroughly. The second coat shall be a 3/9 inch wet coat of weatherproofing compound rein forced with wire mesh and troweled to a smooth finish. The wire mesh shall be secured together at the edges with lacing wires. 5-3.3 COLD SERVICE 5-3.3. I GENERAL . I Insulation Bhall be applied with joints, including contraction slip joints, tightly butted and cemented with Joint adhesive, in such a manner to provide one homogeneous mass of insulation with no ragged or open Joints through y which water vapor can penetrate. Circumferential Joints shall be staggered one half a sectional or block length. ABS-061247 SHELL (ML COMPANY ENGINEERING STANDARDS INSULATION INSTALLATION STANDARD 5-3 AUGUST 1959 PAGE 9 OF 13 .2 All valves, flangeB including manway blind flanges and fittings, shall be insulated with one layer of preformed insulation. The preformed insulation shall be either factory molded or fabricated from block or sectional pipe insulation and cemented with joint adhesive. ' .3 Small voids under insulation around valves',' flanges, fittings and' other irregular surfaces shall be filled with loose mineral wool insulation. Large voids under insulation shall be filled with cut and fitted block in sulation and cemented with Joint adhesive. N Support attachments and other non-operating protrusions shall be insulated a minimum of 18 inches beyond the finished insulation. In addition, after the unit has reached operating temperatures, insulation shall be extended beyond all points where frost or ice forms. * * . ;^; t - 5 Insulation adjacent to insulation supports shall be fitted in Such a 'manner that the support is completely covered and the insulation around the support can be sealed with Joint adhesive. . ' : 6 insulation, after being secured in place/ shall be covered with a l/8 inch wet coat of weatherproofing compound and allowed to dry. -- 7 Insulation on support attachments and other non-operating protrusions shall be covered with flat aluminum sheets. When it is sliripractical to cover in sulation on irregular protrusions, with aluminum final covering, the insula tion shall be covered with weatherproofing compound;. -r .8 Cut outs fornozzles, manways/ support attachments',' etc.,. -shall be carefully - c'-~ fitted, flashed and-sealed with sealing "coinpddhd'to prhvehb ^water penetra- ' tion. - 6-3.3.2 PIPING' . -. /..-.-.c-= >'-'-.'rs-;--- . l . I INSULATION - . ' - I Straight piping 2k inches O.D. and smaller shall he insulated with one layer of sectional pipe insulation. Straight piping larger than 2k inches O.D. shall be insulated-with one layer of block insulation. The ; blocks shall be either curved, flat;-1 or flat blocks :cut Into beveled lags to fit the piping contours'. 2 Insulation on piping which shall be subjected to excessive vibration shall have the bore of the insulation coated with an application of bore coating. The bore coating shall be allowed to dry before the insulation is applied to the piping. .3 Longitudinal contraction Joints shall be provided when the combination of straight run piping length and operating temperature require them to ABS-081248 INSULATION INSTALLATION STANDARD 5-3 AUGUST 1959 jiGE 10 OF 13 SHELL OIL COMPANY ENGINEERING STANDARDS prevent damage to the insulation. Contraction: joints shall consist of 1 inch space between adjacent lengths of insulation filled with loose mineral wopl and covered with an 18 inches long section of oversize in sulation. The oversize insulation section shall he cemented to the regular size insulation with joint adhesive. Contraction Joints, when required, shall be at flanges- wherever possible. . 1 Insulation on straight piping shall be secured with bands on a maximum of 9-inch centers. Insulation on valves, flanges, and fittings shall be secured with bands as required for adequate securement. 5 Insulation supports shall be provided by others at the bottom of verti cal piping 3 inches and larger when a vertical run is in excess of 12 feet long. Supports shall be l/4 inch thick and shall be one half the Insulation thickness in width. .2 FINAL COVERINGS 1 Piping insulation, including valves, flanges, and fittings except welded elbowB inside unit areas' shall be covered with flat aluminum sheets. Piping insulation inside office buildings shall be covered with canvas sheets saturated with Arobol. > 2 Welded elbow insulation inside unit areas shall be covered with pre formed aluminum elbows. 3 Aluminum final covering shall be fitted snugly over the insulation. Circumferential and longitudinal Joints aljall be lapped a minimum of 2 inches and arranged for good water drainage. Longitudinal joints on vertical piping shall be staggered. Longitudinal contraction joints in the insulation Bhall also be covered. N Aluminum final covering shall be machine rolled to .the O.D. of the in sulation and secured with bands on a maximum of 18-inch centers . One band shall be located on each circumferential lap; Each section of final covering on vertical piping larger than 10 inches shall be suppor ted from the next lower section with two S clips made from the banding materials. . 5 Weatherproofing compound final covering shall be 3/8 inch wet coat rein forced at the center with glass fabric and troweled to a smooth finish. The glass fabric shall be lapped 2 inches at the edges. The weather proofing compound final covering and glass fabric shall lap-2 inches under the aluminum final covering on the adjacent piping. ABS-061249 SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION INSTALLATION STANDARO 5-3 AUGUST 1959 PAGE II OF 13 5-3.3.3 VESSELS .1 INSULATION .I The shells of vessels 2k inches O.D. and smaller shall be insulated vith one layer of sectional pipe insulation. The shells of vessels larger than 2k inches O.D. and the heads of all vessels shall be insulated with one layer of block insulation. The blocks shall be either curved, flat or flat blocks cut into beveled lags to fit the shell or head contours. . 2 The vessel shell insulation shall extend down to the bottom of the skirt The top 24 inches of the inside of the Bkirt shall also be insulated. . 3 Longitudinal contraction on vertical vessels shall be compensated for by providing an extra inch,beyond the length of insulation between insula tion supports. Insulation above and below supports shall be fitted to form a 3 inches long male and female slip joint which shall completely cover the support and the void below the support. The one-inch void shall be filled with loose mineral wool insulation. .4 Insulation on the shells of vessels shall bef secured with bands on 9lnch centers. Bands shall be machine stretched and sealed to remove slack only. Insulation on heads and transition sections of vessels shall be secured with bands anchored with lacing wire hairpins to 1/2 inch nut blanks welded to the vessel. Anchors shall be on 12-inch centers. Insulation on the inside of vessel skirts shall be secured with joint adhesive. S'5 Insulation supports Bhal.l be provided by.others on vertical vessels. Supports shall be located on 12 feet 1 inch centers, starting 12 feet 1 inch above the bottom of the skirt'. Supports shall be 1/4 inch thick and shall he one half the insulation thickness in width. ' .2 ' FINAL COVERINGS' ` I Vertical vessel shell and skirt insulation shall be covered with corru gated aluminum BheetB. Horizontal vessel shell insulation, vertical vessel conical head and transition section insulation, and flange in sulation shall be covered with flat aluminum sheets. 2 Vertical, vessel top head insulation shall he covered with flat aluminum sheets. Other vessel head insulation except on conical heads and inside skirt insulation shall be covered with weatherproofing compound. 3 Aluminum final covering shall be fitted snugly over the insulation. Corrugated aluminum sheets shall, be installed with the greater dimension in a vertical position. Circumferential and longitudinal Joints shall be lapped a minimum of 3 inches and arranged for good water drainage. Longitudinal Joints on vertical vessels shall be staggered. Longitudi nal contraction JointB in the insulation shall be covered continuously with the final covering. ABS-061250 IHSULATION INSTALLATION STANDARD 5-3 AUGUST 1959 |AGE 12 OF 13 SHELL 01L COMPANY ENGINEERING STANDARDS .4 Aluminum final covering for vertical vessel top head insulation shall be prefabricated segmental sections flanged, flashed, and through bolted to form a water tight covering. The head final covering shall.lap 4 inches over the aluminum final covering on the adjacent shell. S Aluminum final covering for manway flange insulation shall be a twopiece, prefabricated housing to be secured in place with bands. The design of the housing shall be submitted to Shell for approval. .6 Aluminum final covering shall be secured with bands on 18-inch centers. One band Bhall be located on each circumferential lap on horizontal vessels. The bands shall be machine stretched and sealed to remove slack only. Each section of final covering on vertical vessels shall be sup ported from the next lover section with two S clips made from l/2 inch stainless steel handing materials. . 7 Weatherproofing compound final covering shall be 3/8 inch thick wet coat reinforced at the center with glass fabric and troweled to a smooth finish. The glass fabric shall be lapped 3 inches at the edges. On bottom heads which are not confined within skirts and on heads on. hori zontal vessels the weatherproofing compound and glasB fabric shall lap 4 inches under the aluminum final covering on the adjacent shell. The glass fabric shall be secured with two bands on the 4 inches lapped section. 5-3.3.4 EXCHANGERS .1 INSULATION ; .1 The shells, and channels of exchangers 24 inches. O.D. and smaller Bhall be covered with one layer of sectional pipe insulation. -The shells and channels of exchangers larger than 24 inches O.D. and all shell and channel heads shall be covered with one layer of block insulation. The blocks shall be either, curved, flat or flat blocks cut into beveled, lags to fit shell, channel, or head contours. | .2 Insulation on the shells and channels of `exchangers shall be secured with bands on 9-inch centers. Bands shall be machine stretched and sealed to remove slack only. Insulation jon the heads of exchangers shall be secured with bands anchored with lacing wire hairpins to l/2 inch nut blanks welded to the heads on 12-inch centers. . 3 Insulation supports shall be provided by (others at the bottom of insula tion on vertical exchangers. Supports shall be l/4 inch thick and shall be one half the insulation thickness in width. i . .. 1 ABS-061251 I SHELL OIL COMPANY ENGINEERING STANDARDS INSULATION INSTALLATION STANDARD 5-3 AUGUST 1959 PAGE I 3 OF 13 .2 FINAL COVERINGS .1 Exchanger shell, channel, channel head, and flange insulation shall be covered with flat aluminum sheets. .2 Exchanger shell head insulation 6hall be covered with weatherproofing compound. .3 Aluminum final covering shall be fitted snugly over the insulation. Circumferential and longitudinal joints shall be lapped a minimum of 3 inches and arranged for good water drainage. Longitudinal Joints on vertical exchangers shall be staggered. -N Aluminum final covering for flange and channel head insulation shall be a two-piece, prefabricated housing to be secured in place with bands. The design of the housing shall be submitted to Shell for approval. .5 Aluminum final covering shall be machine rolled to the O.D. of the in sulation and secured with bands on a maximum of l8-inch centers. One band shall be located on each circumferential lap. The bands shall be machine stretched and sealed to remove slack only. Each section of final covering on vertical exchangers shall be supported from the next lower section with two S clips made from the banding material. . 6 Weatherproofing compound final covering shall be a 3/8 inch thick wet coat reinforced at the center with glass fabric and troweled to a smooth finish. The glass fabric shall be lapped 3 inches at the edgeB. The weatherproofing compound final covering and glass fabric shall lap 4 inches under the aluminum final covering on the adjacent shell. The glass fabric shall be secured with one band on the 4 inches lapped sec tion on an shell heads. 5-3.3.5 PUMPS AND COMPRESSORS .1 INSULATION I The cases, flanges, and supports of pumps and compressors. Bhall be in sulated by boxing in with one layer of block insulation and filling the Interior of the box with loose mineral wool insulation. .2 Packing glands shall be-left exposed. .3 The insulation box shall be covered with a 1/8 inch wet coat of weather proofing compound and allowed to dry. ~______________ .2 FINAL COVERING ABS-061252 Pump and compressor insulation shall be covered with a 3/8 inch thick wet coat of weatherproofing compound reinforced at the center with glass fabric and troweled to a smooth finish. The glass fabric shall be lapped 3 inches at the edges. "4